C) Commands
Table 1.3 lists the commands for the 2015-24 and briefly describes them. After a command is sent the
2015-24 sends a return “>” indicating the command has been received and executed.
General Command Format - The general command format is {aaCND...}, where:
{ = start byte
aa = Address (RS-485 only)
C = 1 character, either C (command) or S (status)
N = 1 character command of status request
D = 1 character or more of data (depends on command)
} = stop byte
*
PLEASE NOTE: The two character {aa}(00-31) prefix, in the table below,
should be used ONLY when RS-485, (OPTION-Q), is selected.
Table 1.2 2015-24 Commandds
Command
s
Command
Syntax*
Description
Set Transmitter Frequency
{aaC1xxxxxxx} where:
4 characters - standard (7 characters - Option-X)
• Range: 0950000 to 2150000 kHz
Set Input Level
{aaCIxx}
where:
• xx = 2 characters
• Range: 10 to 40 (-10 to -40 dBm, in 1 dB steps)
Set Transmit Gain
{aaC3xxx}
where:
• xxx = 3 characters (0 to 30dB), 3 characters (-10 to -1dB)
• Range: -10 to 30 (-10 dB to +30 dB, in 1 dB steps)
Enable 10MHz RF Insertion
{aaC5x}
where x =:
(option E ONLY)
• 0 to disable 10MHz RF insertion
• 1 to enable 10MHz RF insertion
Enable Tx
{aaCAx}
where x =:
• 0 to disable (mute) Tx signal
• 1 to enable Tx signal
Enable External 10MHz
{aaCEx}
where x =:
(option E ONLY)
• 0 to disable External 10MHz ref signal
• 1 to enable External 10MHz ref signal
Enable Remote
#
Just # sign
Disable Remote
{aaCR0}
{CR and zero}
2015-24 Manual_Rev.G
Page 7
05/28/13