B) Status Requests
Table 1.2 lists the status requests for the 2015-24 and briefly describes them.
*
PLEASE NOTE: The two character {aa}(00-31) prefix, in the table below,
should be used ONLY when RS-485, (OPTION-Q), is selected.
TABLE 1.1 2015-24 Status Reequests
Status R
equests
Command
Syntax *
Description
Command Status
{aaS1}
Returns {aaS1bbbbbbbcccddAM} where:
• bbbbbbb = Tx frequency in kHz (0950000 to 2150000)
4 characters - standard (7 characters - Option-X)
• ccc = Tx gain (-10 to 30 dB)
• dd = Tx input level (10 to 40 => -10 to -40 dBm)
• A = 0 - summary alarm
• M = Tx RF Status (1 = Normal, 0 = Muted)
10 MHz Reference Status
{aaS2}
Returns {aaS2ER} where:
(option E ONLY)
• E = Ext 10MHz Status (1 = on, 0 = off)
• R = 10MHz RF insertion status (1 = inserted, 0 = NOT inserted)
SSPB Current
{aaS4}
Returns {aaS4bbb} where:
(option V ONLY)
• bbb = SSPB current, range 000 to 250 (0 to 2500 mA)
2015-24 Manual_Rev.G
Page 6
05/28/13