background image

INSTRUCTION MANUAL

MODELS 2005-02P4 and 2005-03P4 Upconverters

 

TABLE OF CONTENTS

PAGE

Warranty

2

1.0 General

3

1.1  Equipment Description

3

1.2  Technical Characteristics

4

2.0 Installation

5

2.1  Mechanical

5

2.2  Front Panel Controls and Indicators

5

2.3  Rear Panel Inputs, Outputs, and Controls

5

2.4  Accessing the PC Card

6

2.5  Operation

7

3.0 Environmental Use Information

8

WARRANTY - The following warranty applies to all Cross Technologies, Inc. products.

All Cross  Technologies, Inc. products are warranted against defective  materials and 
workmanship for a period of one year after shipment to customer.  Cross Technologies, Inc.’s 
obligation under this warranty is limited to repairing or, at Cross Technologies, Inc.’s option, 
replacing parts, subassemblies, or entire assemblies.  Cross Technologies, Inc. shall not be 
liable for any special, indirect, or consequential damages.  This warranty does not cover parts 
or equipment which have been subject to misuse, negligence, or accident by the customer 
during use.  All shipping costs for warranty repairs will be prepaid by the customer.  There 
are not other warranties, express or implied, except as stated herein.

C

ROSS 

T

ECHNOLOGIES, INC.

6170 Shiloh Road

Alpharetta, Georgia 30005

(770) 886-8005

FAX (770) 886-7964

Toll Free 888-900-5588

WEB www.crosstechnologies.com 

E-MAIL [email protected]

2005-02/03 Manual, Rev. J

 Page 2  

  

               08/14/2019

Summary of Contents for 2005-02P4

Page 1: ...in are proprietary to Cross Technologies Inc but may be reproduced or duplicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment When ordering parts from...

Page 2: ...pment to customer Cross Technologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subassemblies or entire assemblies Cross Technol...

Page 3: ...low phase noise these units are used to loop 70 or 140 MHz modulators to L band receivers in uplinks The 70 or 140 MHz carrier input is mixed with a synthesized local oscillator LO signal The output f...

Page 4: ...quency Accuracy 25 kHz max Frequency Step 1 0 MHz minimum 80 10kHz 100 90 1MHz 100kHz dBC Hz Phase Noise Freq Controls L Band Frequency Selection BCD switches with direct readout LO Selection SPDT sli...

Page 5: ...s red when PLL comes out of lock SW5 IF SELECT SPDT slide switch selects 70 or 140 MHz IF in 2005 TEST UPCONVERTER CROSS TECHNOLOGIES INC DC 100MHz FREQUENCY 10MHz 1MHz GHz LO IF C KU 70 140 ALARM FIG...

Page 6: ...o install the PCB gently push the rear panel and PCB assembly completely into the extrusion Make sure the shield goes in the lower channel and the PCB in the next channel above that in the extrusion a...

Page 7: ...d low side LO for Ku band Also note that there will be a spectrum inversion of the input IF modulation with the high side LO Although the 2005 02 operates over it s full 950 to 2050 MHz range with hig...

Page 8: ...ution D Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of circuits could have on over current protection and...

Page 9: ...INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com Printed in USA 2005 02 03 Manual Rev...