2.4 Operation
1. Connect RF cables to the 1584-116S (See Section 2.2).
2. Connect 100-240 ± 10% VAC, 47- 63 Hz to AC on the back panel and observe front panel LED is lit.
NOTE: FOR OPTIMUM PERFORMANCE, THE SPLITTER PORTS SHOULD BE TERMINATED
WITH 75 OHM TYPE F TERMINATIONS WHEN NOT USED.
AC Fuse - The fuse is a 5mm, 2 amp slow blo and is inserted in the far slot in the drawer below the AC
input as shown in Figure 2.6. There is a spare fuse in the near slot. If a fuse continues to open, the power
supply is most likely defective. Note that each power supply module within the chassis also has a fuse
but failure of this fuse indicates the power supply may be defective.
AC Fuse - 2 amp slow blow (Type T),
5 mm X 20 mm
FUSE DRAWER
SPARE FUSE
~
INPUT
100-240± 10%VAC
47-63 Hz
2A MAX
FUSE
TYPE T 2A GDC
250 VOLT
FOR 100 - 240 V~
~
FIGURE 2.6 FUSE LOCATION AND SPARE FUSE
1584-116S Manual, Rev.C
Page 7
12/06/10