JP10, JP110 DO NOT ADJUST THESE!

JP15, JP16, JP17, JP18 - DO NOT ADJUST THESE!

JP25,JP125 - DO NOT ADJUST THESE!

JP26,JP126 - DO NOT ADJUST THESE!

2.4.2  On-Card Switches 
S3, S103 - Initial Channel Select (ICS) Mode
- 4-position DIP switch Selects the Initial Channel Select mode 

when JP1,2,3, JP101,102,103,in Dot and JP4, JP104 in Non-dot.

S3, S103 positions 1,2,3,4 to ON - ICS is enabled. In the ICS mode, the initial channel can be either 
CH1 or CH2 by switching the front panel Manual Select switch to either CH1 or CH2 and then back to 
the Auto position.or by grounding either Remote 1 or Remote 2 pins on J8 and then grounding the 
Remote reset pin on J8 causing the 1582-14 to go back to Auto in the channel last selected remotely if 
both channel alarms are clear or both channels are in alarm. The initial channel can also be selected if 
both channel alarms are clear or both channels are in alarm..
S3, S103 positions 1,2,3,4 to OFF - ICS is disabled (Minimum Auto switching, Return to Last 
State Mode)
 The 1582-14 goes to the last state (CH1 or CH2) it was in when in Auto after Manually or 
Remotely switching and returning to Auto. Auto switching occurs only if current channel alarms and the 
other channel is clear.
S3, S103 normal position - 1,2,3,4 to ON

S4, S104 - DO NOT ADJUST THESE!

S5, S105 DO NOT ADJUST THESE!

1582-725 Manual, Rev. B

 

 

  Page 8

    

          4/10/14

Summary of Contents for 1582-725

Page 1: ...proprietary to Cross Technologies Inc but may be reproduced or duplicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment Printed in USA When ordering parts from Cross Technologies Inc be sure to include the equipment model number equipment serial number and a description of the part CROSS TECHNOLOGIES INC 6170 Shiloh Road Alpharetta Georgia 30005 770...

Page 2: ...nship for a period of one year after shipment to customer Cross Technologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subassemblies or entire assemblies Cross Technologies Inc shall not be liable for any special indirect or consequential damages This warranty does not cover parts or equipment which have been subject to misus...

Page 3: ...lear Factory set mode is generally 1 CH1 Prime Mode When power is first applied and there are no alarms CH1 is selected On power loss CH2 is the selected channel The Manual Select switch and contact closures to Remote Select pins when in Auto select CH1 or CH2 independent of alarms LEDs indicate alarm and switch conditions for CH1 and CH2 REMOTE or MANUAL operation and power on RF connectors are B...

Page 4: ...ls are in alarm SWITCH RESET Resets switch to CH1 if it is good and switch is in the latch mode Also Resets REMOTE by returning operation to Auto Indicators LEDs CH1 ON LINE Turns green when Channel 1 is selected CH2 ON LINE Turns green when Channel 2 is selected MANUAL Turns red when the Manual Select switch manually selects channel 1 or 2 ALARM CH1 Turns red when an external alarm input closure ...

Page 5: ...s J7A J7B Monitors and Controls Connectors J7A TOP J7B BOTTOM Function Pin Description ALARM 1 IN 13 Ground or Open selectable by JP2 JP102 gives CH1 alarm ALARM 2 IN 14 Ground or Open selectable by JP2 JP102 gives CH2 alarm REMOTE 1 IN 1 When in AUTO momentary ground on this pin selects CH1 REMOTE 2 IN 2 When in AUTO momentary ground on this pin selects CH2 REMOTE RESET IN 4 When in LATCH mode gr...

Page 6: ...sition switch as follows LEFT manually select Channel 1 CENTER AUTO switch position determined by alarm and remote closures RIGHT manually select Channel 2 Switch RESET Resets switch to Channel 1 if it is good and switch is in the latch mode Also resets REMOTE selection to normal AUTO operation Common for the Chassis Common for the Chassis Item Description POWER 1 LED Turns green when power is app...

Page 7: ...de on off 3 pin jumper effective when JP1 is in the non dot position With JP3 in the dot and JP1 in the non dot when channel 1 alarms the 1582 14 switch switches to channel 2 and stays there until the reset button is pushed on the front panel or by an external closure to ground on the remote RESET pin on J8 and then it switches to channel 1 If channel 1 alarms are cleared If in the ICS mode and or...

Page 8: ...ote 1 or Remote 2 pins on J8 and then grounding the Remote reset pin on J8 causing the 1582 14 to go back to Auto in the channel last selected remotely if both channel alarms are clear or both channels are in alarm The initial channel can also be selected if both channel alarms are clear or both channels are in alarm S3 S103 positions 1 2 3 4 to OFF ICS is disabled Minimum Auto switching Return to...

Page 9: ...ALL SWITCH POSITIONS IN THE ON SIDE POWER SUPPLY 2 POWER SUPPLY 1 SHOWN IN THE ICS MODE S4 S5 JP2 JP3 JP15 JP16 JP17 JP18 JP1 JP104 JP102 JP103 JP101 S3 S103 JP10 S104 S105 JP109 JP110 FIGURE 2 3 1582 725 PCB Settings Parts Locations 1582 725 Manual Rev B Page 9 4 10 14 ...

Page 10: ...te selection after return to Auto if both channel alarms are clear or both channels are in alarm Auto switching occurs only if current channel alarms and the other channel is clear Non dot SWITCH A JP4 SWITCH B JP104 Dot SWITCH A JP1 JP2 JP3 SWITCH B JP101 JP102 JP103 S3 SWITCH A S103 SWITCH B ALL TO ON Factory set mode is generally 1 CH1 Prime Mode 2 7 Operation a Set the on board controls as des...

Page 11: ... equipment is not compromised Additional space between units may be required E Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of circuits could have on over current protection and supply wiring Appropriate consideration of equipment name plate rating should be used when addressing this concern F Reliable Ea...

Page 12: ...ES INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com Printed in USA 1582 725 Manual Rev B Page 12 4 10 14 ...

Reviews: