MODEL 1582-725 RF Switch

1.0  General

1.1  Equipment Description 

- The 1582-725 RF Switch has two independent switches (A and B) in a single 1 

3/4” chassis. Each switch provides Auto, Manual, or Remote relay switching between CH1 and CH2. Alarm 
conditions on CH1 and CH2 are detected if a contact closure (to ground or an open, selectable) occurs. 
Switching logic can be selected as follows:

1) CH1 Prime Mode

 - Switches from CH1 to CH2 only if CH1 alarms and CH2 is good. 

Switches back to CH1 when it is no longer in alarm or when both CH1 and CH2 are in alarm.

2) Latch to CH2 Mode

 - Switches from CH1 to CH2 if CH1 alarms and CH2 is good. 

Latches to CH2. Push Reset or ground Remote Reset pin to return to CH1 if it has no alarm 
or both CH1 and CH2 are in alarm.

3)  Minimum  Auto  switching,  Initial  Channel  Select  (ICS)  Mode 

- Switch stays on channel last 

selected by Manual or Remote selection after return to Auto if both channel alarms are clear or both 
channels are in alarm. Auto switching occurs only if current channel alarms and the other channel 
is clear.
Factory set mode is generally 

(1) CH1 Prime Mode.

  

When power is first applied and there are no alarms, CH1 is selected. On power loss CH2 is the selected 
channel. The Manual Select switch and contact closures to Remote Select pins (when in Auto), select CH1 or 
CH2 independent of alarms. LEDs indicate alarm and switch conditions for CH1 and CH2, REMOTE or 
MANUAL operation, and power on.  RF connectors are BNC, female. Contact closure inputs and outputs are 
via barrier strip. Dual power supplies provide redundant power to the 1582-725. The chassis is a 1 3/4” rack 
mount.

SWITCH A

MODEL 1582

POWER

1      2

   AUTO   

 CROSS TECHNOLOGIES, INC.

ON-
LINE

MANUAL 
SELECT

REM

ON-
LINE

ALM

CH 1 

CH 2

ALM

MAN

RESET

SWITCH B

   AUTO   

ON-
LINE

MANUAL 
SELECT

REM

ON-
LINE

ALM

CH 1 

CH 2

ALM

MAN

RESET

FIGURE 1.1     Model 1582-725 RF Front Panel

1582-73  BLOCK DIA

CONTROL
LOGIC SWA

AUTO

CH 1 

CH 2

SWITCH 
RESET

  1    2

 ALARM

    1      2   

REMOTE 

REMOTE 
SW. 
RESET

SWITCH A 
SWITCHED 
RF

SWITCH A 
RF 1

SWITCH A  
RF 2

CONTROL
LOGIC SWB

AUTO

CH 1 

CH 2

SWITCH 
RESET

  1    2

 ALARM

    1      2   

REMOTE 

REMOTE SW. 
RESET

FINAL OUTPUT 
SWITCH B 
SWITCHED RF

SWITCH B 
RF 1

SWITCH B  
RF 2

CH1 &CH2 
ALARM

1582-725 Block Diagram

FIGURE 1.2      Model 1582-725 RF Switch Block Diagram (

Each Switch

)

1582-725 Manual, Rev. B

 

 

  Page 3

    

          4/10/14

Summary of Contents for 1582-725

Page 1: ...proprietary to Cross Technologies Inc but may be reproduced or duplicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment Printed in USA When ordering parts from Cross Technologies Inc be sure to include the equipment model number equipment serial number and a description of the part CROSS TECHNOLOGIES INC 6170 Shiloh Road Alpharetta Georgia 30005 770...

Page 2: ...nship for a period of one year after shipment to customer Cross Technologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subassemblies or entire assemblies Cross Technologies Inc shall not be liable for any special indirect or consequential damages This warranty does not cover parts or equipment which have been subject to misus...

Page 3: ...lear Factory set mode is generally 1 CH1 Prime Mode When power is first applied and there are no alarms CH1 is selected On power loss CH2 is the selected channel The Manual Select switch and contact closures to Remote Select pins when in Auto select CH1 or CH2 independent of alarms LEDs indicate alarm and switch conditions for CH1 and CH2 REMOTE or MANUAL operation and power on RF connectors are B...

Page 4: ...ls are in alarm SWITCH RESET Resets switch to CH1 if it is good and switch is in the latch mode Also Resets REMOTE by returning operation to Auto Indicators LEDs CH1 ON LINE Turns green when Channel 1 is selected CH2 ON LINE Turns green when Channel 2 is selected MANUAL Turns red when the Manual Select switch manually selects channel 1 or 2 ALARM CH1 Turns red when an external alarm input closure ...

Page 5: ...s J7A J7B Monitors and Controls Connectors J7A TOP J7B BOTTOM Function Pin Description ALARM 1 IN 13 Ground or Open selectable by JP2 JP102 gives CH1 alarm ALARM 2 IN 14 Ground or Open selectable by JP2 JP102 gives CH2 alarm REMOTE 1 IN 1 When in AUTO momentary ground on this pin selects CH1 REMOTE 2 IN 2 When in AUTO momentary ground on this pin selects CH2 REMOTE RESET IN 4 When in LATCH mode gr...

Page 6: ...sition switch as follows LEFT manually select Channel 1 CENTER AUTO switch position determined by alarm and remote closures RIGHT manually select Channel 2 Switch RESET Resets switch to Channel 1 if it is good and switch is in the latch mode Also resets REMOTE selection to normal AUTO operation Common for the Chassis Common for the Chassis Item Description POWER 1 LED Turns green when power is app...

Page 7: ...de on off 3 pin jumper effective when JP1 is in the non dot position With JP3 in the dot and JP1 in the non dot when channel 1 alarms the 1582 14 switch switches to channel 2 and stays there until the reset button is pushed on the front panel or by an external closure to ground on the remote RESET pin on J8 and then it switches to channel 1 If channel 1 alarms are cleared If in the ICS mode and or...

Page 8: ...ote 1 or Remote 2 pins on J8 and then grounding the Remote reset pin on J8 causing the 1582 14 to go back to Auto in the channel last selected remotely if both channel alarms are clear or both channels are in alarm The initial channel can also be selected if both channel alarms are clear or both channels are in alarm S3 S103 positions 1 2 3 4 to OFF ICS is disabled Minimum Auto switching Return to...

Page 9: ...ALL SWITCH POSITIONS IN THE ON SIDE POWER SUPPLY 2 POWER SUPPLY 1 SHOWN IN THE ICS MODE S4 S5 JP2 JP3 JP15 JP16 JP17 JP18 JP1 JP104 JP102 JP103 JP101 S3 S103 JP10 S104 S105 JP109 JP110 FIGURE 2 3 1582 725 PCB Settings Parts Locations 1582 725 Manual Rev B Page 9 4 10 14 ...

Page 10: ...te selection after return to Auto if both channel alarms are clear or both channels are in alarm Auto switching occurs only if current channel alarms and the other channel is clear Non dot SWITCH A JP4 SWITCH B JP104 Dot SWITCH A JP1 JP2 JP3 SWITCH B JP101 JP102 JP103 S3 SWITCH A S103 SWITCH B ALL TO ON Factory set mode is generally 1 CH1 Prime Mode 2 7 Operation a Set the on board controls as des...

Page 11: ... equipment is not compromised Additional space between units may be required E Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of circuits could have on over current protection and supply wiring Appropriate consideration of equipment name plate rating should be used when addressing this concern F Reliable Ea...

Page 12: ...ES INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com Printed in USA 1582 725 Manual Rev B Page 12 4 10 14 ...

Reviews: