CAUTION – RCBO TEST – TRADE PACKS ONLY
The RCBO device must be tested every time the generator is started and before any appliances are
plugged in. To test, place the RCBO switch to the “ON” position and push the test button on the
device. The switch must trip to the “OFF” position immediately. If it does not trip immediately do
not use the generator and contact your nearest Crommelins Machinery service agent
Electric starter model:
o
If mine spec, turn the battery isolator switch to the “ON” position, twist the emergency stop
switch clockwise to ensure it is open, this procedure must be done before starting generator.
o
Insert the key into the key switch and turn it clockwise to the “I” (on) position to start the
engine,
IF DIESEL GENERATOR,
make sure to turn on the fuel tap by moving the lever to the
down position, turn the key further to the start position until engine starts.
o
These generators are fitted with IP66 weatherproof outlets, an RCD safety switch and MCB
overload protection switches. After starting the generator and before every use check the RCD
switch works by setting the switch to on, then push the TEST button to trip, then reset. If TEST
fails and trips – DO NOT USE THE GENERATOR and contact your nearest service agent.
�
�
�
CAUTION – IF ELECTRIC START FITTED
•
DO NOT
run the starting motor over 5 seconds continuously. If the engine fails to start, return the
key to the “I” (on) position and wait about 10 seconds then start again.
•
DO NOT
turn the key switch to start position when the engine is running to prevent damage of
starting motor.
•
When starting the engine by recoil starter, set the key switch to the “I” (on) position and pull the
starter handle.
STEP 4
After the engine has started, return the choke lever gradually to “OPEN” position.
STEP 5
Warm up the engine without load for a few minutes.
STOPPING THE GENERATOR
STEP 1
Turn off the power switch of the electric equipment and unplug the cord from receptacle of the
generator.
STEP 2
Allow the engine to cool down for approximately 3 minutes at no-load before stopping.
STEP 3
Recoil starter model -
Turn the engine switch to the position ‘O’ (off).
STEP 4
Electric starter model -
Turn the key switch to the STOP position.
STEP 5
Close the fuel valve.
OIL SENSOR
STEP 1
The oil sensor detects the fall in oil level in the crankcase and automatically stops the engine
when the oil level falls below a predetermined level.
STEP 2
When engine has stopped automatically, switch off generator’s AC circuit breaker, allow the
engine to cool, and check the oil level. Refill engine oil to the upper level as outlined by the
section “CHECK ENGINE OIL” and restart the engine.
STEP 3
If the engine does not start by usual starting procedures, re-check the oil level.
7.
WATTAGE INFORMATION
Some appliances need a “surge” of energy when starting. This means that the amount of electrical power
needed to start the appliance may exceed the amount needed to maintain its use.