7
CROMMELINS
™GENERATOR
Operation & Instruction Manual
6. GROUNDING THE GENERATOR
To ground the generator to the earth, connect the grounding lug of the generator to the
grounding spike driven into the earth or to the conductor which has been already grounded
to the earth.
If such grounding conductor or grounding electrode is unavailable, connect the grounding
lug of the generator to the grounding terminal of the electric tool or appliance being used.
7. BATTERY INSTALLATION – (Electric Start Models)
Recommended Battery
Type – Lead-acid battery
Capacity (Ah/5hr) – 12V-21AH or more
Size – Less than 185(L) x 125(W) x 150(H) mm
Death, personal injury and/or property damage may occur unless instructions are followed
carefully.
Use battery of recommended capacity.
Turn the starter switch to the “O” (stop) position when mounting or dismounting battery.
When mounting battery, connect the positive (+) cable first and then the negative (-) cable
to the battery. Be careful not to short battery cables. When dismounting battery, disconnect
negative (-) cable first.
RED CABLE – To positive (+) terminal
BLACK CABLE – To negative (-) terminal
Should a connection be made in an incorrect manner, the generator will not work.
Ensure bolts and nuts are tightened on terminals securely so they will not be loosened by
vibration.
Disconnect battery cables when charging battery.
WARNING