CUSTOM OVERRIDE
Custom override allows the user to set a personalized number of button presses (2-15) required to perform an
emergency override/disarm of the alarm system. This increases the level of security of the system, but you
MUST MEMORIZE
how many button presses you have changed your system to use or the unit will not disarm
in an emergency.
1. Enter programming mode. (See step #1 on page 8)
2. Press program button three times to go to option #3 “Passive Locks/Custom Override”.
3. Press the Buttons (1+2) on the remote transmitter.
4. Press and release the program again the number of times you desire in order to perform emergency disarm
on this alarm system. Press the program button 2-15 times only.
To test feature: Trip alarm system, turn key ON, press the program/valet button 2-15 times as programmed
above then continue to HOLD DOWN valet button on the LAST PRESS for 5 seconds. Alarm should disarm.
If system does not disarm, then disarm with the remote transmitter and try again. If system still does not
disarm, then repeat steps above.
Summary of Contents for CS-2000