DI20/32-M-A/E-S
Created 11/17/2016 2:29 PM
7
BEGINNING SERIAL NUMBE 07093822
3. On the 4’, 5’, and 6’ machines the timers are located on the top of the machine under the
cover. They will be marked “Salt/Sugar Timer.”
4.
To adjust the pump time, use the following procedure:
a. There are two adjustments on the timer. The small adjustment knob sets the maximum
time the timer can run. Cretors will normally set this adjustment for 10s.
10s = 0-10 seconds
1m = 0-1 minute
10m = 0-10 minutes
b. The larger adjustment knob sets the actual run time (percentage of time allowed by the
small adjustment knob). Example: If the maximum setting is set for 10s and the large
knob is set at .9, the timer will run for 9 seconds. Adjust to taste for both timers.
E. Counter Model Installation
The Counter Model Diplomats have 4’ legs, which must be attached at the time of installation.
The legs are required to comply with Sanitation Standards.
F. Ventless Model Installation
The Ventless hood Model Diplomats have the Giles ventless hood integrated into the popper.
If the hood is not functioning, neither will the popper. Once the machine is plugged in, turn on
the “exhaust switch”. When the Ventless Hood is first turned on it goes through a self check
process. The hood will sound an alarm and then the alarm should shut off. Once the hood is
operational, the rest of the machine functions as normal. Also refer the Giles hood instruction
manual for additional information on operation and service.
G. Ansul Installation
An Ansul service technician must be called out to activate the system at start up. There will be
no power to the machine until this is done.
VII. SERVICE INSTRUCTIONS
In the case of improper operation, only a qualified person should perform the
following diagnostic checks, and, if necessary, corresponding adjustments and repairs.
Many of the following procedures may present an electrical shock hazard and can
cause serious injury or death.
Perform work only on de-energized circuits. Failure to do so may lead to electrical
shock resulting in personal injury or death.
A.
Parts
When ordering parts, refer to the parts diagram included in this manual. Always supply the
serial number, model number, and voltage of your popcorn machine.
B.
Kettle Temperature Control
1.
TEMPERATURE CONTROL OPERATION
Summary of Contents for DIPLOMAT 20