mechanism. The mechanism will slide forward. To locate the release latch,
refer to illustration on page 5, showing the front view of the TPS-6X-DSW.
Callout #2 points to the release latch.
2. Remove the four screws holding the cover plate in place, to gain access to
the connectors on the TPS-6X-DSW.
TPS-6X-DSW Installation – Cover Plate Removal
BEFORE MOUNTING THE UNIT INTO
THE WALL, REMOVE THE COVER PLATE
TO ACCESS THE CONNECTORS.
ONCE ALL CABLES ARE CONNECTED,
REPLACE THE COVER PLATE.
3. Hold the TPS-6X-DSW near the back box and connect the
NET
,
VID IN
and
LAN
cables from the back box to the ports on the back of the unit.
(Refer to “Hardware Hookup” on page 13 for details.)
4. Replace the cover plate, using the four screws from step 2.
5. Place the TPS-6X-DSW into the back box (or against the PMK-6X-DSW if
using this instead of the back box) and using the four supplied
#06-32 x 1 1/2” screws (2007254), two at the top and two at the bottom, to
attach the TPS-6X-DSW to the back box, as shown in the illustration on the
following page.
10
•
Wall Mount Docking Station for TPS-6X: TPS-6X-DSW
Operations & Installation Guide – DOC. 6708A