Crestron
ST-VC
Volume Control Module
Cresnet System Hookup Connections for ST-VC
CRESNET SYSTEM
OPTIONAL
POWER PACK
(500 mA)
(1000 mA
for STI-VC)
A/V
EQUIPMENT
NOTE:
USE ST-CNB (SOLD SEPARATELY) TO
CONNECT ST-VC TO CRESNET SYSTEM.
AMPLIFIER &
AUDIO SOURCE
COMMON GND
DAISY CHAIN
TO EXPAND
INPUT
AMPLIFIER
AUDIO OUT
Identity Code
Every equipment and user interface within the network requires a unique identity
code (NET ID). These codes are recognized by a two-digit hexadecimal number
from 03 to FE. The NET ID of each unit must match an ID code specified in the
SIMPL Windows program. The NET ID of each ST-VC has been factory set to
10
.
The NET IDs of multiple ST-VCs in the same system must be unique and changed
from a PC via Viewport, which is available from SIMPL Windows or VisionTools™
Pro-e (VT Pro-e).
NOTE:
VT Pro-e is a Windows compatible software package for creating Crestron
touchpanel screen designs.
The method for changing the unit's NET ID is identical regardless of the software
chosen. Complete the following steps to change the NET ID.
1. Attach one of the ST-VCs to the control system (verify that the
software is running).
2. From the SIMPL Windows or VT Pro-e menu, select
Tools | Viewport
to open the Crestron Viewport.
3. From the Viewport menu, select
Functions | Set Network ID
. The
software checks the baud rate and then opens the "Set Network ID"
window.
4. In the "Set Network ID" window, select the ST-VC from the
Current
Network Devices
text window.
5. From
the
Choose the new network ID for the selected device (Hex):
text box, select the new NET ID for the ST-VC.
Operations Guide - DOC. 5676A
Volume Control Module: ST-VC
•