Crestron
QM-FTDC
FlipTop Data Center
NOTE:
Be careful not to press the buttons while closing the FlipTop, even though
the buttons are disabled when the FlipTop begins to close and all pressed buttons are
released.
Hardware Hookup
Connect the Device
Make the necessary connections as called out in the illustration that follows this
paragraph. Refer to “Network Wiring” on page 16 before attaching the 4-position
terminal block connector. Apply power after all connections have been made.
When making connections to the QM-FTDC, consider the following:
•
Use Crestron power supplies for Crestron equipment.
•
The included cable (domestic units only) cannot be extended.
Underside Hardware Connections for the QM-FTDC
QM:
QUICKMEDIA AUDIO, VIDEO, RGB
AND MIC OUTPUT OVER CAT5
ETHERNET/TELCOM PASS-THROUGH:
8-PIN RJ-45
NET:
TO CONTROL SYSTEM AND OTHER
CRESNET DEVICES
(2) RJ-11 PASS-THROUGH 6-PIN PHONE JACKS:
TELEPHONE AND CONFERENCE EQUIPMENT
(2) MIC/LINE LEVEL INPUTS:
FROM BALANCED CONDENSER OR DYNAMIC
MICROPHONES OR BALANCED/UNBALANCED
LINE LEVEL SOURCES
ETHERNET PASS-THROUGH:
10/100BaseT ETHERNET TO LAN
GROUND
TSID SETUP BUTTON AND LED
120 VAC LINE CORD
(DOMESTIC MODELS ONLY)
(INTERNATIONAL MODELS ONLY)
IEC-320
ELECTRICAL
APPLIANCE
COUPLER
250V-50/60Hz 10A
NOTE:
For optimum performance, Crestron strongly recommends using
CresCAT-QM cable, available from Crestron. Other high-quality/low skew
CAT5e/CAT6 wiring may also be used with varying performance.
NOTE:
The maximum continuous current from equipment under any external load
conditions shall not exceed a current limit that is suitable for the minimum wire
Operations & Installation Guide – DOC. 6312B
FlipTop Data Center: QM-FTDC
•
23