Crestron infiNET CLW-DIM1RF Manual Download Page 4

CLW-DIM1RF, DIMS1RF, & SLVD1RF(W/A/B)

  

 

Wiring Diagram for CLW-DIM1RF (L) / CLW-DIMS1RF (R) 

Installation 

Hot

Neutral

Load

RED

BLACK

WHITE

BLUE

Ground

GREEN

LINE

120VAC

60Hz

60Hz

120VAC

LINE

GREEN

Ground

WHITE

BLACK

RED

Load

Neutral

Hot

 

NOTE:  

The -DIMS1RF must be installed in the same 

wallbox that contains the connections to the load.

 

NOTE:

  The -DIM1RF, -DIMS1RF, and -SLVD1RF 

require a neutral wire for operation. If no neutral is 
present, contact a licensed electrician for installation or 
contact Crestron Customer Service for alternative wiring 
options. 

WARNING:  

Turn off power at the circuit breaker. 

Installing with power on can result in serious personal 
injury and damage to the device. 

NOTE:

  The RED (Load) and BLACK (Hot) wires are 

#14 AWG. The BLUE (Slave) and WHITE (Neutral) 
wires are #18 AWG. The GREEN (Ground) wire is #16 
AWG.  

NOTE:  

New installations should be checked for short 

circuits prior to installing the -DIM1RF, -DIMS1RF, or  
-SLVD1RF. With power off, close the circuit and restore 
power. If the lights do not work or a breaker trips, check 
and correct the wiring or fixture (if necessary). Install the 
-DIM1RF, -DIMS1RF, or -SLVD1RF only when the 
short is no longer present. 

The warranty is void if the  

-DIM1RF, -DIMS1RF, or -SLVD1RF is installed and 
operated with a shorted load

CLW-DIMS1RF with CLW-SLVD1RF 
Wiring 

NOTE:

 The -DIMS1RF must be installed in the same 

wallbox that contains the connections to the load.

 

The following wiring diagram illustrates installation of 
the -DIMS1RF with multiple -SLVD1RFs. 

1.  Turn power off at the circuit breaker. 

2.  If installing multiple dimmers (-DIM1RF or  

-DIMS1RF), note the serial number on each 
device and make sure they are being installed in 
the proper location. 

Wiring Diagram of CLW-DIMS1RF with multiple CLW-
SLVD1RFs 

Hot

Neutral

Load

RED

CLW-DIMS1RF

BLACK

WHITE

CLW-SLVD1RF

BLUE

BLACK

BLUE

Ground

Ground

GREEN

GREEN

LINE

120VAC

60Hz

WHITE

Ground

GREEN

BLACK

BLUE

CLW-SLVD1RF

WHITE

 

3.  Wire the device for the appropriate application. 

Choose either “CLW-DIM1RF / CLW-
DIMS1RF Wiring” o
“CLW-DIMS1RF with 
CLW-SLVD1RF Wiring”
, shown on this page 
and the following page. 

NOTE:

  Alternative wiring methods can be obtained from 

the Dealer/Tech Resources | Design Center section of the 
Crestron website (http://www.crestron.com/dealer-
tech_resources/design_center/hot_design_tips_and_ 
diagrams/tech_sales_tips/). 

NOTE:  

Do not connect the BLUE (Slave) wire to the 

Black (Hot) or RED (Load) wires. 

CLW-DIM1RF / CLW-DIMS1RF Wiring 

NOTE:

  The RED (Load) and BLACK (Hot) wires are 

#14 AWG. The BLUE (Slave) and WHITE (Neutral) 
wires are #18 AWG. The GREEN (Ground) wire is #16 
AWG.  

NOTE:

  The -DIM1RF and -DIMS1RF require a neutral 

wire for operation. If no neutral is present, contact a 
licensed electrician for installation or contact Crestron 
customer service for alternative wiring options. 

NOTE:  

If a -DIMS1RF is installed without a  

-SLVD1RF, the BLUE lead (Slave) should be capped. 

The following wiring diagram illustrates installation of 
the -DIM1RF or -DIMS1RF. 

4.  Push all Class 1 power wires back into the 

wallbox and fasten the device to the wallbox 
with the provided screws. 

5.  Attach decorative faceplate. 

6. Restore 

power. 

4  

  Stand Alone Wall Box Dimmer :  CLW-DIM1RF, DIMS1RF, & SLVD1RF 

Installation Guide – DOC. 6292 

Reviews: