Use transformers that incorporate 
thermal protection or fuse transformer 
primary windings to prevent 
transformer failure due to overcurrent. 

Read before installation. 

• 

Codes: Install in accordance with all local and 
national electrical codes. 

Multigang Installations 

• 

CAUTION

:  TO REDUCE THE RISK OF 

OVERHEATING AND POSSIBLE DAMAGE 
TO OTHER EQUIPMENT, DO NOT INSTALL 
TO CONTROL A RECEPTACLE OR A 
MOTOR OPERATED APPLIANCE (i.e. BATH 
FAN). 

In multigang installations, several controls are grouped 
horizontally in one wallbox. For a smooth appearance, 
one-piece multigang faceplates (not supplied) can be 
installed. 

1.  When combining controls in a wallbox, remove 

inner side sections prior to wiring (refer to the 
following figure). 

• 

Wiring: Use copper wire only. For supply 
connections, use wires rated for at least 75°C. 

Inner Sections of Multiganged Switches 

• 

Lamp Type: The -DIM1RF, -DIMS1RF, and -
SLVD1RF are designed for use with 
permanently installed incandescent, magnetic 
low voltage, or tungsten-halogen only.  

REMOVE INNER SECTIONS

DO NOT REMOVE OUTER SECTIONS

 

• 

Temperature: The -DIM1RF, -DIMS1RF, and -
SLVD1RF are designed to be used where 
temperatures are between 32° to 104°F (0° to 
40°C). 

• 

Wallboxes: Devices mount in standard 
wallboxes. For easy installation, Crestron 
recommends using 3 ½” deep wallboxes. Several 
devices can be installed in one wall box 
(multigang). This requires the removal of side 
sections (refer to diagram on page 3) and the 
derating of the dimming device. For a smooth 
appearance, one-piece multigang faceplates (not 
supplied) can be installed. 

The load capacity must also be derated. The 
following charts provide derating information for 
various applications. 

• 

Other Switch Devices: Mechanical 3- or 4-way 
switches will not work with the -DIM1RF, -
DIMS1RF, or -SLVD1RF. 

Derating Information for Incandescent and Tungsten Halogen 
Applications 

• 

Spacing: If mounting one device above another, 
leave at least 4 ½” vertical space between them. 

Part 

Number 

No Side 

Removed 

One Side 

Removed 

Two Sides 

Removed 

-DIM1RF 1000W 

600W 

400W 

-DIMS1RF 

1000W 

600W 

400W 

-SLVD1RF 

No Derating Necessary 

• 

Low Voltage Applications: Use with core and 
coil (magnetic) low voltage transformers only. 
Do not use any solid-state electronic low voltage 
transformers. 
 
Operation of a low voltage circuit with all lamps 
inoperative or removed may result in current 
flow in excess of normal levels. To avoid 
transformer overheating and premature 
transformer failure, Crestron recommends the 
following: 

Derating Information for Magnetic Low Voltage Applications

*

 

Part 

Number 

No Side 

Removed 

One Side 

Removed 

Two Sides 

Removed 

-DIM1RF 1000VA/750W 600VA/450W 400VA/300W 

-DIMS1RF 

1000VA/750W 

600VA/450W 

400VA/300W 

-SLVD1RF 

No Derating Necessary 

*  VA ratings are for input power to the transformer. If you do not 

know the input power requirement of the transformer, use the bulb’s 
wattage rating to determine proper rating. 

 

Do not operate low voltage circuits 
without operative lamps in place. 

2.  To remove a side section, bend the side section 

back and forth with a pair of pliers until the 
section breaks off from the mounting plate. Use a 
file or sandpaper to remove any excess metal. 

 

Replace burned-out lamps as quickly as 
possible. 

Installation Guide – DOC. 6292 