Crestron
DM-RMC-100-1
DigitalMedia™ Room Controller, CAT
IP Configuration
If the DM-RMC-100-1 is used in a standalone configuration (i.e. without
a DM switcher), use Crestron Toolbox to create the IP table entry for the
DM-RMC-100-1.
NOTE:
If the DM-RMC-100-1 is connected directly to a DM switcher,
the IP table entry for the DM-RMC-100-1 is created automatically.
1.
Use the Device Discovery Tool in Crestron Toolbox to find the IP
address of the DM-RMC-100-1. Then, display the “System Info”
window (click the icon) and select the DM-RMC-100-1 entry
from the Address Book.
2.
Select
Functions
|
IP Table Setup
.
3.
Add, modify or delete entries in the IP table. The DM-RMC-100-1
can have only one IP table entry.
4.
A defined IP table can be saved to a file or sent to the device.
Operations & Installation Guide – DOC. 6743-2G
Room Controller, CAT: DM-RMC-100-1
•
31