Crestron C2COM-2 Operations & Installation Manual Download Page 17

Crestron 

C2COM-2/3

 

 2-Series RS-232/422/485 Expansion Cards

 

Return and Warranty Policies 

Merchandise Returns / Repair Service 

1.  No merchandise may be returned for credit, exchange, or service without prior 

authorization from CRESTRON. To obtain warranty service for CRESTRON 
products, contact the factory and request an RMA (Return Merchandise 
Authorization) number. Enclose a note specifying the nature of the problem, name 
and phone number of contact person, RMA number, and return address. 

2.  Products may be returned for credit, exchange, or service with a CRESTRON Return 

Merchandise Authorization (RMA) number. Authorized returns must be shipped 
freight prepaid to CRESTRON, 6 Volvo Drive, Rockleigh, N.J., or its authorized 
subsidiaries, with RMA number clearly marked on the outside of all cartons. 
Shipments arriving freight collect or without an RMA number shall be subject to 
refusal. CRESTRON reserves the right in its sole and absolute discretion to charge a 
15% restocking fee, plus shipping costs, on any products returned with an RMA. 

3.  Return freight charges following repair of items under warranty shall be paid by 

CRESTRON, shipping by standard ground carrier. In the event repairs are found to 
be non-warranty, return freight costs shall be paid by the purchaser. 

CRESTRON Limited Warranty 

CRESTRON ELECTRONICS, Inc. warrants its products to be free from manufacturing defects in 
materials and workmanship under normal use for a period of three (3) years from the date of 
purchase from CRESTRON, with the following exceptions: disk drives and any other moving or 
rotating mechanical parts, pan/tilt heads and power supplies are covered for a period of one (1) 
year; touchscreen display and overlay components are covered for 90 days; batteries and 
incandescent lamps are not covered.  

This warranty extends to products purchased directly from CRESTRON or an authorized 
CRESTRON dealer. Purchasers should inquire of the dealer regarding the nature and extent of the 
dealer's warranty, if any. 

CRESTRON shall not be liable to honor the terms of this warranty if the product has been used in 
any application other than that for which it was intended, or if it has been subjected to misuse, 
accidental damage, modification, or improper installation procedures. Furthermore, this warranty 
does not cover any product that has had the serial number altered, defaced, or removed.  

This warranty shall be the sole and exclusive remedy to the original purchaser. In no event shall 
CRESTRON be liable for incidental or consequential damages of any kind (property or economic 
damages inclusive) arising from the sale or use of this equipment. CRESTRON is not liable for 
any claim made by a third party or made by the purchaser for a third party.  

CRESTRON shall, at its option, repair or replace any product found defective, without charge for 
parts or labor. Repaired or replaced equipment and parts supplied under this warranty shall be 
covered only by the unexpired portion of the warranty. 

Except as expressly set forth in this warranty, CRESTRON makes no other warranties, expressed 
or implied, nor authorizes any other party to offer any warranty, including any implied warranties 
of merchantability or fitness for a particular purpose. Any implied warranties that may be imposed 
by law are limited to the terms of this limited warranty. This warranty statement supercedes all 
previous warranties. 

Trademark Information

 

All brand names, product names, and trademarks are the sole property of their respective owners. Windows 
is a registered trademark of Microsoft Corporation. Windows95/98/Me/XP and WindowsNT/2000 are 
trademarks of Microsoft Corporation.

 

Operations & Installation Guide - Doc. 8192 

2-Series RS-232/422/485 Expansion Cards:  C2COM-2/3  

  13 

Summary of Contents for C2COM-2

Page 1: ...Crestron C2COM 2 C2COM 3 2 Series RS 232 422 485 Expansion Cards Operations Installation Guide ...

Page 2: ...n by the Technical Documentation department at Crestron Electronics Inc 15 Volvo Drive Rockleigh NJ 07647 1 888 CRESTRON All brand names product names and trademarks are the property of their respective owners 2003 Crestron Electronics Inc ...

Page 3: ...ce 3 Installation and Hookup 3 Installation 4 Hookup 4 Important Information for PRO2 Users 6 Programming Software 7 Programming with the Crestron AppBuilder 7 Programming with SIMPL Windows 7 Problem Solving 11 Troubleshooting 11 Further Inquiries 12 Future Updates 12 Return and Warranty Policies 13 Merchandise Returns Repair Service 13 CRESTRON Limited Warranty 13 Operations Installation Guide D...

Page 4: ......

Page 5: ...ge number of Cresnet devices For more information refer to the latest revision of the Network Poll Accelerator Operations Guide Doc 6087 The C2COM 2 3 supports baud rates up to 115 200 bps and higher with the Network Poll Accelerator and a variety of communication parameters with hardware and software handshaking Valid parameters are shown in the functional summary Functional Summary Supports RS 2...

Page 6: ...or 2 Series control system update files have a CUZ extension and can be obtained from the Downloads Software Updates section of the Crestron website www crestron com Refer to note after this footnote NOTE Crestron software and any files on the website are for Authorized Crestron dealers and Crestron Authorized Independent Programmers CAIP only New users may be required to register to obtain access...

Page 7: ...tandards per EMC and Radiocommunications Compliance Labelling N11785 NOTE This device complies with part 15 of the FCC rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Installation and Hookup The C2COM 2 3 cards are designed fo...

Page 8: ...unding strap or grounded workstation 1 Disconnect power from the control system 2 Remove the two screws and blank faceplate from the desired slot in the control system using a Phillips screwdriver 3 Align the C2COM 2 3 with the card guides in the open slot and slide the expansion card into the slot 4 Firmly press both ends of the C2COM 2 3 faceplate to seat the expansion card in the control system...

Page 9: ...COM 2 3 TXD RS 232 Transmit Data 4 From C2COM 2 3 TXD RS 422 Transmit Data Idles high 5 Ground RS 232 and RS 422 Signal Common 6 To C2COM 2 3 RXD RS 422 Receive Data Idles high 7 From C2COM 2 3 RTS RS 232 Request to Send 8 To C2COM 2 3 CTS RS 232 Clear to Send 9 From C2COM 2 3 TXD RS 422 Transmit Data Idles low RS 422 transmit and receive are balanced signals requiring two lines plus a ground in e...

Page 10: ... to monitor transmission and reception traffic on every COM type device and card that is active in the SIMPL Windows program loaded in the control system including the C2COM 2 3 PRO2 Front Panel Sample of Main Menu When the COM button is pressed default front panel page the display shows a list of devices and cards to be monitored one at a time The user selects the slot and port for the C2COM 2 3 ...

Page 11: ...on 2 04 04 or later with library update file 209 C2COM 3 only requires version 2 01 06 or later Requires SIMPL Cross Compiler version 1 1 Crestron Database 15 9 1 or later Application Builder 1 1 9 1 1 9 for C2COM 2 or later Requires SIMPL Windows Programming with the Crestron AppBuilder The easiest method of programming but does not offer as much flexibility as SIMPL Windows The Crestron AppBuild...

Page 12: ...e upper pane of the System Views The PRO2 with its associated communication ports is displayed in the System Views upper pane PRO2 System View The System Views lower pane displays the PRO2 system tree This tree can be expanded to display and configure the communications ports Expanded PRO2 System Tree C2Y Card Slot in Configuration Manager The C2Y Card Slots 01 03 can hold a C2COM 2 3 Once a C2COM...

Page 13: ...s tab NOTE If a different serial device to is connected to Port A these values may need to be changed to the required settings for the device SIMPL Windows can automatically set the values for a controlled device that is selected from the Crestron device database The Crestron database includes numerous serial devices with default logic and pre configured communication settings that are compatible ...

Page 14: ...e flow of data between devices Some devices require a break to enable synchronization The break input drives the transmit pin of the associated COM port low 00 Hex at half the baud rate thus interrupting transmission of data Some break signals can be 17 to 20 bits of logic low whereas others hold transmission low for as long as break remains high Again the hardware documentation will contain infor...

Page 15: ...orrect serial port settings Verify the communication parameters assigned in the Device Settings window as described in the Programming section C2COM 2 3 does not function Programming error Check SIMPL Windows program Framing Error or Parity Error Cable noise or improper comm settings in program Verify communication settings Serial Settings tab and wiring Overrun Error or RX Buffer full C2COM 3 is ...

Page 16: ... 5093 2160 In Australia and New Zealand call Creston Control Solutions at 61 2 9737 8203 Future Updates As Crestron improves functions adds new features and extends the capabilities of the C2COM 2 3 additional information may be made available as manual updates These updates are solely electronic and serve as intermediary supplements prior to the release of a complete technical documentation revis...

Page 17: ...ps are not covered This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer Purchasers should inquire of the dealer regarding the nature and extent of the dealer s warranty if any CRESTRON shall not be liable to honor the terms of this warranty if the product has been used in any application other than that for which it was intended or if it has been subj...

Page 18: ...2 Series RS 232 422 485 Expansion Cards Crestron C2COM 2 3 14 2 Series RS 232 422 485 Expansion Cards C2COM 2 3 Operations Installation Guide Doc 8192 This page intentionally left blank ...

Page 19: ...Crestron C2COM 2 3 2 Series RS 232 422 485 Expansion Cards Operations Installation Guide Doc 8192 2 Series RS 232 422 485 Expansion Cards C2COM 2 3 15 This page intentionally left blank ...

Page 20: ...Crestron Electronics Inc Operations Installation Guide DOC 8192 15 Volvo Drive Rockleigh NJ 07647 03 03 Tel 888 CRESTRON Fax 201 767 7576 Specifications subject to www crestron com change without notice ...

Reviews: