note, to assign the join number. In the
Page Channel
area of this window, a specific
number can be assigned or with the appropriate button assign the next or highest
available.
Asserting the digital signal for a particular page join number (fb*** on the SIMPL
Window symbol) results in a jump to that page. When the system is on a page with a
join number, the digital signal corresponding to that join number is asserted for as
long as the system is on that page (press *** on the SIMPL Windows symbol).
In this note, *** is used to denote a wildcard.
"Front Panel Editor" Window
Front Panel Symbol
A powerful tool to assist programmers in naming and routing signals for the LCD
screen is the
Synchronize Signals
command. While the panel appears on the PC
screen, select
Panel | Synchronize Signal Names
to automatically name all the input
and output signals for the front panel in the SIMPL Windows program. To confirm
the assignment and display the signal names, double click on
Slot-10: C2I-PRO2-
LCDPANEL Pro2 Front Panel,
which is available from the Central Control Modules
folder in the
Program View
of SIMPL Windows’ Program Manager. The symbol
appears in
Detail View
, as shown after this paragraph.
Front Panel Symbol Displayed in SIMPL Windows’ Detail View of Programming Manager
Operations Guide - DOC. 5957A