![Crestron AV2 Operation Manual Download Page 32](http://html1.mh-extra.com/html/crestron/av2/av2_operation-manual_2683828032.webp)
2-Series Integrated Dual Bus Control System
Crestron
AV2 & PRO2
The Crestron AppBuilder is fully integrated with Crestron's suite of software
development tools, including SIMPL Windows, VT Pro-e, Crestron Database, User
IR Database, and User Modules Directory. The Crestron AppBuilder accesses these
tools behind the scenes, enabling you to easily create robust systems.
Programming with SIMPL Windows
SIMPL Windows is Crestron’s graphical, Windows-based development tool for
programming control systems. The SIMPL Windows interface provides two
workspaces: the Configuration Manager, for configuring the control system,
touchpanels, and controlled network devices; and Program Manager, for designing
the logic and functionality of the control system.
In addition, you can use Crestron’s powerful Viewport utility to accomplish multiple
system tasks, such as uploading the program to the control system and performing
diagnostic functions. Together with the Crestron Database, these tools provide you
with the essential components you need to program the AV2/PRO2. Crestron
software is available on CD-ROM, or can be downloaded from the Crestron website
(
)—registration is required for downloading.
NOTE:
The information in this section assumes that the reader has knowledge of
SIMPL Windows. If not, refer to the extensive help information provided with the
software.
AV2/PRO2 Device Library Symbols
In Configuration Manager, drag the AV2, AV2 with Card Cage, or PRO2 from the
Control Systems folder of the
Device Library
to
System Views
. The AV2 with Card
Cage and PRO2 symbols are identical; the AV2 does not provide the Y-Bus
expansion slots. Refer to the following illustration.
System Views of the AV2 (without optional card cage) and PRO2
Slot 1, 2, 3: Y-Bus Expansion Slots (Optional on AV2)
The 40Mb/s Y-BUS supports existing CNX control cards and permits adding
multiple IR, serial communications, and/or relay ports to the control system.
Slot 4: C2I-COM6
The AV2 and PRO2 provide six serial COM ports (A through F) that enable RS-232,
RS-422, and RS-485 communication.
28
•
Integrated Dual Bus Control System: AV2 & PRO2
Operations Guide - DOC. 5957A