NOTE!
The equipment must be stored in a dry, dark and well-ventilated space. Lanyards are to be hung in gentle bights.
Appropriate bags and/or transport boxes are to be used when transporting the equipment.
NOTE!
All VERTIQUAL PPE for working at heights are marked with labels. The label carries the manufacturer’s name,
product name, model designation, unique serial number, date of manufacture, EN standard and the Certification
institutes number.
NOTE!
The maximum service life of the product is 6-8 years from the date of purchasing. The storage time (in proper
conditions) before the first use should not exceed 2 years. Incorrect handling and wear can reduce the length of
useful life. The product must be removed from service if it has: corrosive damage, broken threads, cut edges,
discoloured webbing, heavily worn, corroded metal parts, if it is not capable of functioning, has missing markings.
MAINTENANCE
NOTE!
The equipment must be stored in a dry, dark and well-ventilated space protected against steam, high temperature,
sharp edges, vibrations and UV-light. The equipment shall be kept clean for the best function and durability. Metal
parts can be blown clean with compressed air. Avoid lubricating oil! Slightly soiled equipment can be washed in
tepid water with a soft brush. A mild soap solution can be used. Heavily soiled equipment can be machine washed
in a wash bag with a phosphate-free washing detergent using a 40¡ programme. Wet equipment should be hung up
to dry. The equipment shall dry by itself without being exposed to heat sources.
INSPECTION
Warning!
For the user’s safety the product must be inspected at least once every twelve months to ensure its function and
durability (read EN-365).
NOTE!
Inspections are to be made more often with frequent usage of the equipment or use in aggressive environments.
Warning!
The inspection must be performed by a qualified person that has an inspection certificate and in accordance wit the
manufacturer’s inspection procedures.
NOTE!
The product label must be legible!
LOG
Each component of a system for protection against falling (read EN363:2008) shall be entered in a log. The log is
to be filled in at least every twelve months by a “duly qualified person”. (See equipment log on the last page).
REPAIR
Product repairs may only be carried out by the manufacturer. EEC type inspection made by: INCDPM Institute for
Research and Development in Labour Safety and Protection – Bucharest. European Notified Body no. 1805
Using instructions
Please hold the harness on
the back ring. Please put the
harness over the shoulders
and close the chest buckle.
Please close the leg belts.
Please adjust the webbings to
the right lengths.
Please close the positioning
belt. Please adjust the
webbing to the right length.
Closing of the regular buckles
(standard)