STEP 11:

Remove the nut from the threaded nipple of 
the photocell and insert the threaded nipple 
of the photocell through the hole in the cover. 
The body of the photocell and the o-ring on 
the threaded nipple should remain on the 
inside surface of the cover.

STEP 12:

Tighten the nut onto the exposed end of the 
threaded nipple to secure the photocell to the 
cover.

STEP 13:

Wire the photocell by following the wiring 
instructions included with the photocell.

STEP 14:

Connect supply ground lead to luminaire 
ground lead.

STEP 15:

Replace the wiring compartment cover that 
was removed in Step 3. Tighten screws to 30 
in-lbs (3.5 N

·

m).

ADJUSTABLE ARM MOUNT WITH TWIST-LOCK PHOTOCELL- REQUIRES USE OF  

NTX-AA-3R ACCESSORY AND TWIST-LOCK PHOTOCELL

NOTE: 

Area lights are only designed for 

mounting orientation from 0° (horizontal) to 

45° tilt.

NOTE: 

Area lights are not to be used as 

uplights.

STEP 1:

Plug the female end of the quick connect, 
supplied with the trunnion, into the male 
connector on the luminaire. Make sure the two 
halves lock together. See 

Figure 1.

STEP 2:

Position luminaire to be assembled to 
adjustable arm face down with mounting holes 
facing towards you.

IMPORTANT:

 Adjustable arm with Twist Lock 

Photocell must be mounted with twist lock 
receptacle on the right side of the adjustable 
arm as viewed from behind luminaire.

STEP 3:

Align the four holes in the upper adjustable 
arm with the four tapped holes in the 
luminaire housing. Attach the adjustable 
arm to the luminaire using the (4) 5/16” (8 
mm) bolts and lockwashers supplied with the 
adjustable arm kit. Tighten bolts to 132 in-lbs 
(15 N

·

m). See 

Figure 8.

STEP 4:

Remove wiring compartment cover on 
adjustable arm by removing (2) screws. See 

Figure 8.

STEP 5:

Feed supply leads up through the tenon that 
the luminaire will be mounted on.

STEP 6:

Route supply leads through open end of the 
adjustable arm and into wiring compartment.

NOTE:

 It may be necessary to disassemble 

the upper and lower portions of the adjustable 
arm in order to run the leads into the wiring 
compartment. If disassembly is necessary, 
remove the 3/8” (10 mm) bolt and lockwasher 
inside the wiring compartment and route 
leads into wiring compartment. See  

Figure 8.

 Reassemble upper and lower arm 

halves and replace 3/8” bolt and lockwasher. 
Do not tighten bolt at this time.

STEP 7:

Strain relief is required for electrical 
connections on slip fitter mounts at heights of 
25’ (7.6 m) and above. Tie a knot in the supply 
leads above the hole where the leads enter 
the wiring chamber to reduce the strain on 
the connections. Make sure knot will not slip 
through opening in wiring compartment.

STEP 8:

Slip lower adjustable arm over 2 -3

/

8” (60 

mm) O.D. heavy wall pipe or tenon making 
sure not to pinch any leads. Aim the luminaire 
in the proper direction and hand tighten all 
four Allen head set screws against outer 
wall of tenon. Once all four screws are hand 
tightened, secure them by tightening them to 
140 in-lbs (16 N

·

m).

STEP 9:

If 3/8” bolt holding the two halves of the 
adjustable arm together was not loosened in 
Step 6, loosen the bolt (DO NOT remove it) at 
this time.

STEP 6:

Strain relief is required for electrical connections on slip 
fitter mounts at heights of 25’ (7.6 m) and above. Tie a knot 
in the supply leads above the hole where the leads enter 
the wiring chamber to reduce the strain on the connections. 
Make sure knot will not slip through opening in wiring 
compartment.

STEP 7:

Slip lower adjustable arm over 2 -3

/

8” (60 mm) O.D. heavy 

wall pipe or tenon making sure not to pinch any leads. Aim 
the luminaire in the proper direction and hand tighten all four 
Allen head set screws against outer wall of tenon. Once all 
four screws are hand tightened, secure them by tightening 
them to 140 in-lbs (16 N

·

m).

STEP 8:

If 3/8” bolt holding the two halves of the adjustable arm 
together was not loosened in Step 5, loosen the bolt (DO NOT 
remove it) at this time.

STEP 9:

Tilt the luminaire to the desired angle and tighten the 3/8” 
(10 mm) bolt to 19 ft-lbs (25 N

·

m) to lock the adjustable arm 

in place.

STEP 10:

Remove the center knockout form the wiring compartment 
cover by striking knockout with a punch and hammer.

Remove the Bolt at 

the Center Inside 

the Cover Plate to 

Separate the Two 

Halves

(2) Screws for 

Removal of Wiring 

Compartment 

Cover

Tighten the Screws 

Here to Fix the 

Adjustable Arm on 

the Pole

Lower Half of the 

Arm to be Fixed on 

the Mounting Pole

Upper Arm to be 

Fixed on to the 

Luminaire Head 

using (4) bolts

Twist Lock 

Photocell 

Receptacle

Supply Leads

Summary of Contents for NTA Series

Page 1: ...ting orientation from 0 horizontal to 45 tilt NOTE Area lights are not to be used as uplights STEP 1 Plug the female end of the quick connect supplied with the trunnion into the male connector on the luminaire Make sure the two halves lock together See Figure 1 STEP 2 Align the four holes in the inner trunnion with the four tapped holes in the luminaire housing Attach the trunnion to the luminaire...

Page 2: ...tion from 0 horizontal to 45 tilt NOTE Area lights are not to be used as uplights STEP 1 Plug the female end of the quick connect supplied with the trunnion into the male connector on the luminaire Make sure the two halves lock together See Figure 1 STEP 2 Position luminaire to be assembled to trunnion optic side down with mounting holes facing towards you IMPORTANT Trunnion with Twist Lock Photoc...

Page 3: ...ing the two halves of the adjustable arm together was not loosened in Step 5 loosen the bolt DO NOT remove it at this time STEP 9 Tilt the luminaire to the desired angle and tighten the 3 8 10 mm bolt to 19 ft lbs 25 N m to lock the adjustable arm in place STEP 10 Make the wiring connections inside the wiring compartment per the Electrical Connections section STEP 11 Replace the wiring compartment...

Page 4: ...tment and route leads into wiring compartment See Figure 8 Reassemble upper and lower arm halves and replace 3 8 bolt and lockwasher Do not tighten bolt at this time STEP 7 Strain relief is required for electrical connections on slip fitter mounts at heights of 25 7 6 m and above Tie a knot in the supply leads above the hole where the leads enter the wiring chamber to reduce the strain on the conn...

Page 5: ...lled NOTE Template is not to scale STEP 8 Mount bottom half of direct arm to pole by threading 5 16 8 mm x 3 76 mm bolt with lock washer through top hole in arm through top hole in pole and into top threaded hole of backing plate inside pole Thread 5 16 8 mm x 2 51 mm bolt with lock washers through lower slot in arm lower hole in pole and into bottom threaded hole of backing plate See Figure 10 Ti...

Page 6: ...6 of 8 LPN00631X0001A0_B C L 2 000 51 mm 1 000 25 4 mm ø0 344 9 mm hole 2 Required ø0 500 13 mm hole NOT TO SCALE 2 000 51 mm 11 ...

Page 7: ...ge 6 for pole drilling if pole is not pre drilled NOTE Template is not to scale STEP 10 Mount bottom half of direct arm to pole by threading 5 16 8 mm x 3 76 mm bolt with lock washer through top hole in arm through top hole in pole and into top threaded hole of backing plate inside pole Thread 5 16 8 mm x 2 51 mm bolt with lock washers through lower slot in arm lower hole in pole and into bottom t...

Page 8: ...ot installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CAN ICES 005 A NMB 005 A ELECTRICAL CONNECTIONS STEP 1 Make the following Electrical Connections to supp...

Page 9: ...isés comme luminaire à éclairage dirigé vers le haut ÉTAPE 1 Branchez l extrémité femelle du raccord rapide fourni avec le tourillon dans le connecteur mâle du luminaire Assurez vous que les deux moitiés se verrouillent ensemble Voir Figure 1 ÉTAPE 2 Alignez les quatre trous du tourillon interne avec les quatre trous taraudés du boîtier du luminaire Fixez le tourillon au luminaire à l aide des qua...

Page 10: ... ne doivent pas être utilisés comme luminaire à éclairage dirigé vers le haut ÉTAPE 1 Branchez l extrémité femelle du raccord rapide fourni avec le tourillon dans le connecteur mâle du luminaire Assurez vous que les deux moitiés se verrouillent ensemble Voir Figure 1 ÉTAPE 2 Positionnez le luminaire à assembler au tourillon avec le côté optique vers le bas et les trous de montage orientés vers vou...

Page 11: ...t les deux moitiés du bras ajustable ensemble n a pas été desserré à l étape 5 desserrez le NE PAS le retirer à cette étape ÉTAPE 9 Inclinez le luminaire à l angle désiré et serrez le boulon de 10 mm 3 8 po à 25 Nm 19 pi lb pour bloquer le bras réglable en place ÉTAPE 10 Effectuez les branchements de fils à l intérieur du compartiment des fils conformément à la section Branchements électriques ÉTA...

Page 12: ...des fils Voir Figure 8 Réassemblez les moitiés supérieure et inférieure du bras et replacez le boulon de 10 mm 3 8 po et la rondelle frein Ne serrez pas le boulon à cette étape ÉTAPE 7 Une réduction de tension est nécessaire pour les connexions électriques sur les montages sur glissière à des hauteurs de 7 6 m 25 pi et plus Faites un nœud aux fils d alimentation au dessus de l orifice où les fils ...

Page 13: ...é inférieure du bras direct sur le poteau en enfilant un boulon et rondelle de blocage de 8 mm 5 16 po x 76 mm 3 po par le trou supérieur du bras par le trou supérieur du poteau et dans le trou fileté supérieur de la plaque de support à l intérieur du poteau Enfilez un boulon de 8 mm 5 16 po x 51 mm 2 po avec rondelle de blocage par la fente inférieure du bras le trou inférieur du poteau et dans l...

Page 14: ...6 sur 8 LPN00631X0001A0_B C L 51 mm 2 000 po 25 4 mm 1 000 po Trou ø 9 mm 0 344 po 2 Requis NON À L ÉCHELLE 51 mm 2 000 po ø0 500 13 mm hole 11 ...

Page 15: ...au s il n est pas prépercé REMARQUE Le gabarit n est pas à l échelle ÉTAPE 10 Montez la moitié inférieure du bras direct sur le poteau en enfilant un boulon et rondelle de blocage de 8 mm 5 16 po x 76 mm 3 po par le trou supérieur du bras par le trou supérieur du poteau et dans le trou fileté supérieur de la plaque de support à l intérieur du poteau Enfilez un boulon de 8 mm 5 16 po x 51 mm 2 po a...

Page 16: ...t utilisé selon le manuel d instructions peut causer une interférence nuisible aux communications radio L utilisation de cet équipement dans une zone résidentielle va sans doute causer une interférence nuisible où il sera requis que l utilisateur corrige l interférence à ses propres frais CAN ICES 005 A NMB 005 A RACCORDEMENTS ÉLECTRIQUES ÉTAPE 1 Effectuez les connexions électriques suivantes au c...

Reviews: