Guangzhou Creator electronics Ltd. Co
2012-01
WWW.CREATOR1997.COM
6
User’s Manual of WiFi Conference System
2
、
Press“
”or “
” to move the cursor
,
every
time when pressing the direction key, the indicator
will be on for once; select “MIC MODE” to
configure, press “ENTER” to confirm. Then
“ENTER” key indicator will be on, and LCD
monitor displays the setup of MIC mode option.
3
、
Press“
”or “
” to move the cursor
,
Select
“NORMAL (quota mode), at the meantime the
indicator will be on, and LCD monitor displays
relevant information.
4
、
Finally, press“ENTER”to finish the operation.
You may directly press MIC MODE in navigation
panel, access to menu setup, and follow the
above step 3 and step 4 to finish the operation. It
will be more convenient and express. Likewise
the other keys on navigation panel (including
ACTIVE MICRO’S, BASS, TREBLE, VOLUME).
2.4.2 AFC Key Operation
Press the AFC key on host panel to initiate
anti-feedback function, at the same time, the
corresponding indicator will be on. Press AFC key
again to stop the function and the indicator will be
off.
The operation of ANC (anti-noise control) function
and AGC (auto-gain control) function on the panel
is the same as AFC key.
2.5 ETHERNET Cable Production
The system adopts CAT-5 (category 5 cabling) as
wiring, connecting the network devices via RJ-45
connectors on both ends of
CAT-5. The standard connection of UTP is not
stipulated freely, as symmetric layout of cable
connectors has to be ensured. In this way, the
internal interference arising within cables can be
offset. Generally, HSYV has 4 pairs of twisted thin
lines inside, marked in different colors.
Two connections of twist pair: EIA/TIA 568B
standard and EIA/TIA 568A standard.
T568A
line order
1
2
3
4
5
6
7
8
G
W
G
O
W
B
B
W
O
Br
W
Br
T568B
line order
1
2
3
4
5
6
7
8
O
W
O
G
W
B
B
W
G
Br
W
Br
G:green; W: white; O:orange; B: blue; Br:brown
Direct-through line
:
both ends are connected in
accordance with T568B line order.
Cross wire
:
one end is connected in accordance
with T568A line order
,
another end is in
accordance with T568B line order.
When connecting to network router,
direct-through wire connection is adopted; when
connecting to PC control, cross wire connection is
adopted.
2.6 Connecting to Infrared Audio
Distribution System
The connection between wireless conference
system and CREATOR infrared audio distribution
system
is
via
12-way
audio
output
in
CR-WiFi6101 host and 11+1-way audio input
channels.
Connect
any
way
to
conduct
simultaneous transmission. The hosts for use with
CREATOR infrared audio distribution system are:
◆
CR-IR3000 Infrared Transmission Host
◆
CR-IR2000-12 Infrared Transmission Host