Flow Heating Unit Manual

1

 General

1.3

 Liability and warranty

All information and instructions in this manual have been compiled in accordance with current regulations, the current 

state of engineering technology and our many years of knowledge and experience.
The actual scope of delivery may differ for special designs, utilisation of additional order options or due to the latest 

technical changes to the explanations and representations described herein. In case of questions, please contact the 

manufacturer.

1.4

 Copyright 

The instruction manual, including any text, drawings, images and other depictions, is protected by copyright. 

Reproduction in any manner and form - including excerpts - as well as the utilisation and/or communication of the 

content is forbidden without permission in writing from the manufacturer. Any non-compliance is liable for damages. 

All other rights are reserved.

1.5

 Declaration of Conformity

The device corresponds to the latest standards and EU directives.
We certify this in the EC Declaration of Conformity.
If necessary, we will gladly send you the according Declaration of Conformity.
A copy of the Declaration of Conformity is provided on page 22.

NOTE! 

This manual should be read carefully before starting work on and with the device, in particular before 

commissioning! The manufacturer accepts no liability for damage and faults that arise from non-compliance 

with the operating instructions.
The manual must be kept directly on the device and accessible to all persons working on or with the device. 

We reserve the right to make technical changes to the product in the context of improving the usage 

properties and further development.

NOTE! 

The graphical representations in this manual may differ slightly from the actual design of the device.

GENERAL / 

4

Summary of Contents for BU FH2101

Page 1: ...FLOW HEATING UNIT MANUAL...

Page 2: ...5 2 Safety 5 5 6 6 2 1 General 2 2 Safety instructions for use of the device 2 3 Intended use 2 4 Caution 7 3 Transport packaging and storage 7 7 7 3 1 Transport inspection 3 2 Packaging 3 3 Storage...

Page 3: ...roduct and must be accessible at all times in the immediate vicinity of the device for the installation operation maintenance and cleaning staff 1 2 Explanation of symbols Important safety and technic...

Page 4: ...form including excerpts as well as the utilisation and or communication of the content is forbidden without permission in writing from the manufacturer Any non compliance is liable for damages All ot...

Page 5: ...2 2 Safety instructions for use of the device The specifications regarding operational safety are based on the regulations of the European Union valid at the time of manufacturing of the device If th...

Page 6: ...warm not for warming of prepared dishes 2 4 Caution This product gets hot warning signs must be used and be visible to guests when the product is in use This product has warning labels on the plug and...

Page 7: ...throw away the cardboard packaging of your device It might be useful for storage purposes when moving or if you need to send the device to our service centre in case of damage Remove the outer and in...

Page 8: ...ak Dekton Dim 530 325 61 mm 20 8 12 8 2 4 Note 20 C to 140 C continuously adjustable Flow Walnut Heating Unit BU_FH2201 Plug UK Type G Power 230v 50Hz 500w BU_FH2202 Plug EU Type F 2 pin Power 230v 50...

Page 9: ...e data of the local power grid with the technical specifications of the unit see nameplate Connect the device only if they match Follow the safety instructions WARNING Hot surface During operation som...

Page 10: ...ght Electrical connections The socket circuit must be secured to at least 16A Install the device so the plug is accessible so that the appliance can be quickly disconnected from the mains if necessary...

Page 11: ...g this key you can increase the parameter value or scroll the parameter list Key SET Holding this key the set point is indicated additionally this key is used for setting parameters Key Down Pressing...

Page 12: ...rried out by customer service WARNING The residual heat indicator indicates whether the combination plate is still hot As long as the combination plate is still hot above 40 C after switching off the...

Page 13: ...cial cleaners can be used for cleaning Do not use abrasives that could scratch the surface of the combination plates Never scrape the painted surface of the combination plate with a knife fork metal s...

Page 14: ...Mains plug not plugged in properly Electricity supply fuse has blown Pull out the plug and insert it correctly Check fuse test device at another outlet NO HEATING Power supply interrupted Heating ele...

Page 15: ...e must be disposed of at the end of its service life in accordance with local regulations It is advisable to contact a specialised waste management company or to contact the local disposal service in...