Frozen Gourmet Programming Guide
44
4550000
TEST THE SUREVEND™ SYSTEM
1.
Press
, then press
until the display shows one of the following:
SV.TST OK
This means the SureVend™ system is operating properly.
SV.TST XX
XX represents the location of a blockage. The sensing zone num-
bers 1 - 9 may appear (1 being closest to the glass), or the letter H,
designating a blockage in the gum & mint unit. This display
changes as the location of the blockage changes, accompanied by a
beep. You may use this screen to test the product coverage of the
SureVend™ sensors, but the accuracy may be somewhat lower than
in actual vend situations.
SV.TST CAL
This means that calibration values are high. Press
to view
the calibration values. This condition may be caused by dirt, mis-
alignment of the SureVend™ sensors, or a partial blockage of a sen-
sor.
•
From any of the previous displays, press
to view the real-time calibration
values. Press
to return to the
SV.TST
screen.
• A calibration value of 0 indicates a shorted detector. This will
normally require replacing the hinge-side PC assembly.
• A calibration value of 1 means that the zone could not be cali-
brated, indicating a blocked or damaged sensor.
• Calibration values above A are abnormal and may require adjust-
ing the alignment or cleaning the sensors.
SV.TST COMM
This indicates a loss of communication with the SureVend™ sys-
tem. Check all harness connections between the main controller
and the SureVend™ controller.
2.
CONTINUE.
DOWNLOAD DATA TO A PDCD
1.
Connect your portable data collection device (PDCD) per its operating instructions.
2.
If data does not download into your PDCD upon connection, press
. Data is
downloaded into your PDCD.
NOTE
Depending upon the setting selected in SET PRINTER OR DEX
OPTIONS (page 6), data may be cleared after the download is com-
plete.
3.
CONTINUE.