background image

 

2

IMPORTANT SAFETY INSTRUCTIONS  

INTRODUCTION  

 

Thank  you  for  purchasing  our  CRANE  Ultrasonic  Humidifier.  Each  unit  has  been 
manufactured  to  ensure  safety  and  reliability.  Before  using  the  humidifier  for  the  first 
time, please read the instructions carefully, and keep them for further reference

.   

WARNING! READ AND SAVE THESE INSTRUCTIONS

Failure to follow

 

all 

the instructions listed below may result in electric shock, fire and/or serious personal 
injury.  

 

1.

 

Do not carry water tank by handle when it is filled with water.  It is 

advisable to carry filled water tank with two hands.

 

2.

 

DO NOT operate outdoors; this humidifier is intended for indoor use only.

  

3.

 

Always have water in the water tank when operating the unit.   

4.

 

Use only clean, cool tap water to fill the tank (filtered or distilled water is 

recommended to avoid white dust if tap water is too hard).  DO NOT use hot water.

  

 

5.

 

Be sure that the filling cap of the tank is firmly tightened. Always have the mist 

direction nozzle and the mist chamber in place while the unit is operating. Place the 

mist direction nozzle so it aims away from children, walls, furniture, and electrical 

appliances. 

 

6.

 

Use only a 110-120VAC outlet. 

 ALWAYS plug and unplug unit with dry hands. 

7.

 

Never operate the unit with a damaged cord or plug.  

8.

 

Always place the unit on a smooth, lint free, non-metallic, waterproof, level 

surface, and away from direct sunlight. Keep the cord away from heated surfaces 

and areas where it could be walked on or tripped over. Unplug the unit when not in 

use and whenever you clean or move the unit.  

9.

 

Do not add medication of any type into the nozzle, base or water tank. Do not 

cover any openings on the unit or insert objects into any openings.  

10.

 

The unit should not be left unattended in a closed room as the air could become 

saturated and leave condensation on walls or furniture.  Leave room door partly 

open. 

11.

 

When cleaning the inside of the unit keep water away from the air outlet /fan vent.  

The exterior may be wiped with a damp cloth, except the electrical controls,

 only 

when the unit is off and unplugged.

  Humidifier requires regular cleaning.  

Refer to cleaning instructions. 

12.

 

Do not tilt or tip the unit or attempt to empty or fill it while it is in operation.  

13.

 

Do not use a detergent to clean any parts of the unit that contain water. Always 

use a few drops of bleach with water to clean humidifier. Detergent film dissolved 

in the water supply can interfere with the output of the unit.  

SAVE THESE INSTRUCTIONS

Summary of Contents for EE-864

Page 1: ...2 1 GALLON 7 56 LITER ULTRASONIC HUMIDIFIER MODEL EE 864 PLEASE READ AND SAVE ALL INSTRUCTIONS TO ENSURE THE SAFE AND EFFECTIVE USE OF THIS APPLIANCE ...

Page 2: ...ety Instructions P 2 General Safety Instructions P 3 List of Main Parts P 4 Tech Specifications Contents of Packaging P 5 Operation and Use P 5 7 Maintenance P 8 9 Trouble Shooting Service Center Information P 10 Warranty Information P 11 Warranty Card P 12 ...

Page 3: ...es 6 Use only a 110 120VAC outlet ALWAYS plug and unplug unit with dry hands 7 Never operate the unit with a damaged cord or plug 8 Always place the unit on a smooth lint free non metallic waterproof level surface and away from direct sunlight Keep the cord away from heated surfaces and areas where it could be walked on or tripped over Unplug the unit when not in use and whenever you clean or move...

Page 4: ...d must be arranged so that it will not drape over the countertop or tabletop where it can be pulled on by children or tripped over accidentally ELECTRIC POWER If electric circuit is overloaded with other appliances your appliances may not operate properly The appliances should be operated on a separate electrical circuit from other operating appliances POLARIZED PLUG This appliance has a polarized...

Page 5: ...Power Light Fig 1 Fig 2 Top of Water Tank 6 Vapor Outlet Channel 7 Water Tank Handle Fig 2 Fig 3 Water Basin 8 Nebulizer 9 Vaporization Chamber 10 Fan Vent 11 Valve Opener 12 Water Level Sensor Fig 3 Fig 4 Bottom of Water Tank 13 Water Tank Valve 14 Water Tank Cap 15 Vapor Outlet Channel Fig 4 Fig 5 Water Tank Lid 16 Water Tank Lid 17 Vapor Output Slot Fig 5 ...

Page 6: ...rface for best performance This is to help disperse the mist in the air and prevent it from being knocked or tipped over CHECK WATER LEVEL SENSOR Make sure that the water level sensor is secured properly Refer to cleaning and maintaining water level sensor on page 9 for instructions on how to assemble water level sensor CHECK FAN VENT This fan vent is located on the bottom of the humidifier The pu...

Page 7: ...led water DO NOT use hot water Use cool tap water DO NOT add any medication to other additives to the water DO NOT pour water into Vapor Outlet Channel part 6 Fig 2 on page 4 Fig 7 4 Replace the water tank cap aligning the threads on the tank with the threads on the cap and turn it clockwise See Fig 8 Fig 8 5 Turn the tank over holding one hand by the top handle and another hand under tank Place f...

Page 8: ...AN ELEVATED NON METALLIC LINT FREE WATERPROOF LEVEL SURFACE FOR BEST PERFORMANCE Adjust the vapor control so that the vapor rises up and gets absorbed by the room air Do not turn on too high output as the vapor cannot be absorbed by the air and accumulates on the surface around the humidifier If the humidifier is placed near a fan or air conditioning outlet the vapor may be forced down by the fore...

Page 9: ...ith a soft cloth dampened in the bleach or white vinegar and water solution Rinse the water basin with cool water to remove any smell DO NOT IMMERSE WATER BASIN IN WATER 3 Wipe all exteriors surfaces of the base with a soft dry cloth Do not immerse the base in water or use water to clean the base An electric shock may result or the humidifier may be damaged GENERAL MAINTENANCE AND CLEANING Before ...

Page 10: ... on the pin by pulling it up see Fig 12 Remove the water float and cap and clean by wiping the parts with a soft damp cloth Replace the parts by first putting the water float onto the pin and then pressing the plastic cap on the end of the pin to secure the float see Fig 13 Do not use excessive force Fig 11 Fig 12 Fig 13 STORING YOUR HUMIDIFIER Allow the appliance to dry completely before storing ...

Page 11: ... there is water in the tank Check for possible lime deposits on the water level float or the nebulizer Make sure that nothing blocks the vapor output slot Check that the air vent on bottom of humidifier is not blocked Empty the humidifier and rinse the water basin with cool tap water and allow to dry for 15 to 30 min White dust appears and settles outside the humidifier Area tap water may have too...

Page 12: ...ions provided with the product This warranty does not apply to normal wear and tear as well as commercial use The warranty is non transferable and applies only to the original purchase and does not extend to subsequent owners of the product Liability under this warranty is limited to repair or replacement In no event shall liability exceed the purchase price paid by the purchaser of the product Un...

Page 13: ...ut the warranty card and include it with a copy of the dated sales receipt In return you will receive your repaired item or a new product at the service center s discretion This Ultrasonic Humidifier was tested and meets our stringent quality standards This product is warranted to be free from manufacturing defects in original materials including original parts and workmanship for 1 year with proo...

Page 14: ...13 ...

Reviews: