6
SUCTION/DISCHARGE .........
3" X 3" NPT Female
LIQUID TEMPERATURE .......
160°F (71°C) Continuous
VOLUTE/WEARPLATE
B
.......................
Cast Iron ASTM A-48, Class 30
SB .....................
316 Stainless Steel,
Replaceable
CASE B
.......................
Cast Iron ASTM A-48, Class 30
SB .....................
316 Stainless Steel
PEDESTAL .............................
Cast Iron ASTM A-48, Class 30
IMPELLER:
Design ...............
Open Type, Passes 3/4" Solids
Material
B
.......................
Cast Iron ASTM A-48, Class 30
SB .....................
316 Stainless Steel
Dynamically Balanced, ISO G6.3
IMPELLER SHAFT ..............
Stainless
Steel
LOCKING COLLAR ..............
Stainless Steel. Serves as
Shaft
Slinger
SQUARE RINGS ................... B -
Buna-N
SB -
Viton®
HARDWARE .......................... B -
Corrosion Resistant Steel
SB -
Stainless Steel
PAINT .................................... B -
Air Dry Enamel
SB -
Two Part Epoxy
SEAL: B
Design
..............
Single Mechanical
Lubrication ........
Grease, with Self-Feeding
Lubricator
Material .............
Rotating Faces - Carbon
Stationary Faces - Ceramic
Elastomer - Buna-N
Hardware - 300 Series Stainless
SB
Design
..............
Single Mechanical
Lubrication ........
Pumped Fluid
Material .............
Rotating Faces - Carbon
Stationary Faces - Ceramic
Elastomer - Viton
Hardware - 300 Series Stainless
BEARING:
B19 & SB19 Design ..............
Double Row, Ball
B21 & SB21 Design ..............
Single Row, Ball
Lubrication ........
Grease
Load
..............
Radial & Thrust
CHECK VALVE:
Material
............ B -
Valve Flap-Neoprene
SB
- Valve Flap - Viton
Weight-Cast Iron ASTM A-48,
Class
30
OPTIONAL EQUIPMENT .......
Seal Material, Case Heater,
Stainless Hardware; High Temperature Control; Flex Coupled
Assy., with Base & OSHA Guard; Right Hand V-Belt Drive
Assy., Left Hand V-Belt Drive Assy., and In-Line Vertical V-
Belt Drive Assy., with Base, Motor Adjusting Base & OSHA
Guard.
inches
(mm)
SECTION: A - PUMP SPECIFICATIONS: B19, SB19, B21, SB21
IMPORTANT !
1.) DO NOT USE FOR PUMPING FLUIDS WITH A FLASH POINT OF LESS THAN 100°F.
2.) MAKE CERTAIN THAT PUMP AND/OR MOTOR ASSEMBLY AND CONTROLS HAVE THE APPROPRIATE RATINGS FOR THE GIVEN APPLICATION
AREA CLASSIFICATION. (ie DIVISION I, AGENCY LISTING ETC.)
Summary of Contents for Crown B12 Series
Page 12: ...12 MODEL B4 B6 B9 ...
Page 14: ...14 MODEL SB4 SB6 SB9 ...
Page 16: ...16 MODEL B12 ...
Page 18: ...18 MODEL SB12 ...
Page 20: ...20 MODEL BH7 ...
Page 22: ...22 MODEL SBH7 ...
Page 24: ...24 MODEL B19 B21 ...
Page 26: ...26 MODEL SB19 SB21 ...
Page 32: ...Notes ...