
14
Motor Housing
NOTE:
Position unit upright, using 4” pvc
coupler to avoid resting unit on the lower
shaft.
Loosen cable clamp bolts and lock washers from
motor housing. Remove cord from motor housing by
pulling straight up while using a rocking motion.
Remove retaining snap ring with a medium fl at tip screwdriver. Using a 1/4-20 bolt, thread it into
the center of the terminal block. Pull straight up with a rocking motion to remove the terminal block.
Disconnect all wire connections noting where each wire is connected. The bottom of the block has a
number located next to each pin for reference. If pump is equipped with temperature-moisture sensors,
remove in same manner as the power cord.
19
22
23
24
21
20
Summary of Contents for Barnes SGV 2 HP
Page 18: ...18 Inner Seal From intermediate coupling press out stationary seal with a flat screwdriver 34 ...
Page 23: ...23 Pin Placement Diagram Figure Figure B B ...
Page 29: ...29 SGV 2HP Exploded View Figure Figure C C ...
Page 31: ...31 Notes ...
Page 32: ...CRANE PUMPS SYSTEMS INC 420 THIRD STREET PIQUA OHIO 45356 U S A ...