4
DISCHARGE ..................
2” NPT, Vertical, Bolt-on Flange
LIQUID TEMP ................
200°F (93°C) Intermittent
MOTOR HOUSING ........
Cast Iron ASTM A-48, Class 30
VOLUTE .........................
Cast Iron ASTM A-48, Class 30
SEAL PLATE .................
Cast Iron ASTM A-48, Class 30
IMPELLER
Design ...........
2 Vane, Open with Pump out vanes
on Back side. Dynamically
balanced, ISO G6.3
Material ........
Cast Iron ASTM A-48, Class 30
SHAFT ............................
416 Stainless Steel
SQUARE RINGS ............
Buna-N
HARDWARE ..................
300 Series Stainless Steel
PAINT .............................
Air dry enamel, top coat
SEAL
Design ..........
Single Mechanical, or Tandem
Mechanical with oil fi lled reservoir
Material ........
Rotating Faces - Carbon
Stationary Faces - Ceramic
Elastomer - Buna-N
Hardware - 300 series stainless steel
CORD ENTRY ................
15 ft. (4.5m) Cord. Plug on 120 volt
Quick
connect.Custom molded for
sealing and strain relief
SPEED ...........................
1750RPM, 60Hz (nominal)
UPPER BEARING:
Design ..........
Single Row, Ball, Oil Lubricated
Load .............
Radial
LOWER BEARING:
Design ..........
Single Row, Ball, Oil Lubricated
Load .............
Radial & Thrust
MOTOR:
Design ..........
NEMA L, Single phase,
Torque
Curve,
Oil Filled, Squirrel
Cage
Induction
Insulation ......
Class F
SINGLE PHASE .............
Split Phase, Includes overload
protection in motor
OPTIONAL EQUIPMENT..
Inlet Strainer*
(*) 3/4” Spherical Soilds handling with optional inlet strainer.
SECTION: A - PUMP SPECIFICATIONS:
inches
(mm)
IMPORTANT !
1.) PUMP MAY BE OPERATED “DRY” FOR EXTENDED PERIODS WITHOUT DAMAGE TO MOTOR AND/OR SEALS.
2.) THIS PUMP IS NOT APPROPRIATE FOR THOSE APPLICATIONS SPECIFIED AS CLASS I DIVISION I HAZARDOUS LOCATIONS.
3.) INSTALLATIONS SUCH AS DECORATIVE FOUNTAINS OR WATER FEATURES PROVIDED FOR VISUAL ENJOYMENT MUST BE INSTALLED IN
ACCORDANCE WITH THE NATIONAL ELECTRIC CODE ANSI/NFPA 70 AND/OR THE AUTHORITY HAVING JURISDICTION. THIS PUMP IS NOT
INTENDED FOR USE IN SWIMMING POOLS, RECREATIONAL WATER PARKS, OR INSTALLATIONS IN WHICH HUMAN CONTACT WITH PUMPED
MEDIA IS A COMMON OCCURRENCE.
4.) MUST
USE
A
HIGH TEMPERATURE
WIDE ANGLE LEVEL CONTROL IN HIGH TEMPERATURE APPLICATIONS.