background image

9

PARTS LIST

ITEM 

QTY. 

 PART 

NO. 

 DESCRIPTION 

  

 23240 

  Switch 

  

 23225M 

  Motor 

  

 

08182 

 

 

Set Screw 

5/16-18 x .38” Lg, Stainless 

 23204 

  Coupling 

  

 20669 

  Screen 

  

 09379 

  Stop 

Collar 

  

7 1   23152-23.00 

  Float 

Rod, 

23.00” 

1100EXP   

 1 

 23152-47.00 

 Float 

Rod, 

47.00” 

1148EXP  

 

09403 

 

 

Slotted Hd Set Screw 

1/4-20 x .25” Lg, Brass 

9 1   23141-20.75 

  Shaft, 

20.75” 

1100EXP   

 1 

 23141-44.75 

 Shaft, 

44.75” 

1148EXP  

10 

 09373 

  Float 

Copper 

 

11 

 09354-A 

  Volute 

Housing 

  

12 

 20553 

  Collet 

  

13 

 09355-A 

  Base 

  

14 

 

08169 

 

 

Cap Screw 

1/4-20 x .50” Lg, Bronze 

15 

 23148-21.88 

 Column 

Assy, 

21.88” 

1100EXP  

 1 

 23148-45.88 

 Column 

Assy, 

45.88” 

1148EXP  

16 

 23143 

  Bearing 

  

17 

 23147 

  Pin 

  

18 

 

21236 

 

 

Cap Screw 

3/8-16 x 1” Lg 

 

19 

 23208 

  Float 

Rod 

Bracket   

20 

 09356-C 

  Impeller 

  

21 

 23103-A 

  Adapter 

  

22 

 23239 

  Switch 

Bracket 

  

25 

 15-5-1 

  Hex 

Nut 

1/4-20, 

Stainless 

 

26 

 

21022 

 

 

Scocket Hd Set Screw(Not Shown)  5/16-18 x .63” Lg   

27 

 

1-4-1 

 

 

Hex Hd Screw 

1/4-20 x .62” Lg, Stainless 

28 

 20-5-1 

  Flat 

Washer 

.25”, 

Stainless 

 

Summary of Contents for Barnes 1100EXP Series

Page 1: ...rogram product changes may occur As such Crane Pumps Systems reserves the right to change product without prior written notification 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax 937 773 7157 Fax 905 457 2650 www cranepumps com Form No 094685 Rev E Series 1100EXP 1148EXP 1 3 HP 1750 RPM 60 Hz Class I Group D Class II Groups...

Page 2: ...Make sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety devices in place Always replace safety devices that have been removed during service or repair Secure the pump in its operating position so it can not tip over fall or slide DO NOT exceed manufacturers recommendation for maximum performance as this could cause the motor to overheat DO NOT re...

Page 3: ...m NEMA START CODE FULL LOAD AMPS LOCKED ROTOR AMPS A DIM B DIM C DIM 1 1100EXP 1 3 115 230 1 60 1750 P 6 4 32 0 34 56 878 24 06 611 18 00 457 1148EXP 1 3 115 1 60 1750 M 6 4 32 0 58 56 1487 48 06 1221 42 00 1067 IMPORTANT 1 PUMP MAY BE OPERATED DRY FOR EXTENDED PERIODS WITHOUT DAMAGE TO MOTOR AND OR SEALS 2 THIS PUMP IS APPROPRIATE FOR THOSE APPLICATIONS SPECIFIED AS CLASS I DIVISION II HAZARDOUS ...

Page 4: ...ton Ontario 905 457 6223 SECTION C INSTALLATION C 1 Location These pumping units are self contained and are recommended for use in a sump or basin This pump is designed to pump effluent or wastewater nonexplosive and noncorrosive liquids that are free of solids and abrasives They are for use in hazardous residential light industrial sump applications Class l Group D Class ll Groups E F G The sump ...

Page 5: ...prong individually If the reading is other than infinity a leakage through stator insulation or moisture in the windings is occurring and the stator must be removed dried out and rechecked A reading at zero indicates a dead short and the stator will have to be replaced DO NOT LET THE PUMP CYCLE OR RUN IF AN OVERLOAD CONDITION OCCURS C 4 Operation 1 Close disconnect switch to motor 2 Briefly operat...

Page 6: ... 3 SERIAL NUMBER The Serial Number block will consist of a six digit number which is specific to each pump and may be preceded by a alpha character which indicates the plant location This number will also be suffixed with a four digit number which indicates the date the unit was built Date Code EXAMPLE A012345 0490 Serial Number A012345 Date Code 0490 April of 1990 60 Hz Testing is performed with ...

Page 7: ... cutter for freedom of operation security and condition Clean cutter and inlet of any obstruction 9 Loosen union slightly to allow trapped air to escape Verify that turn off level of switch is set so that the suction is always flooded Clean vent hole 10 Remove examine for damage Replace pump stator if required 11 Repair fixtures as required to eliminate leakage 12 Check pump temperature limits flu...

Page 8: ...8 ...

Page 9: ...5 1148EXP 10 1 09373 Float Copper 11 1 09354 A Volute Housing 12 3 20553 Collet 13 1 09355 A Base 14 5 08169 Cap Screw 1 4 20 x 50 Lg Bronze 15 1 23148 21 88 Column Assy 21 88 1100EXP 1 23148 45 88 Column Assy 45 88 1148EXP 16 2 23143 Bearing 17 2 23147 Pin 18 4 21236 Cap Screw 3 8 16 x 1 Lg 19 1 23208 Float Rod Bracket 20 1 09356 C Impeller 21 1 23103 A Adapter 22 1 23239 Switch Bracket 25 1 15 5...

Page 10: ...formance specifications must be in writing and such writing must be signed by our authorized representative Due to inaccuracies in field testing if a conflict arises between the results of field testing conducted by or for user and laboratory tests corrected for field performance the latter shall control RECOMMENDATIONS FOR SPECIAL APPLICATIONS OR THOSE RESULTING FROM SYSTEMS ANALYSES AND EVALUATI...

Page 11: ...nt To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty To complete the Warranty Registration Form go to http www cranepumps com ProductRegistration If you have a claim under the provision of the warranty contact your local Crane Pumps...

Page 12: ...Notes ...

Reviews: