background image

14

PARTS KITS

Seal Repair Kit ...........P/N: 110477

Overhaul Kit ...............P/N: 110478

Cutter Kit ...................P/N: 110479

PARTS LIST

ITEM

QTY

PART NO.

DESCRITION

1

1

105196

105196HA

Motor Housing

Motor Housing w/Press cutout or AU

2

1

084343

Seal Plate

3

1

101771

Suction Housing

4

1

117679

Rotor

5

1

117678

Stator

6

1

101772

Stator Retainer

7

1

101773A

Pumpout Spacer

8

1

101774

Radial Cutter

9

1

082085

Shredding Ring

10

1

067562

Shaft Seal C/C/B

11

1

027269

Tetra Seal

12

113oz

029034

Cooling Oil

14

1

039734

Ball Bearing

15

1

038255

070965

Capacitor

115V/1Ph, 370V, 60MFD

230V/1Ph, 370V, 25MFD

16

1

102171

O-Ring

17

1

102643BG

101729BG

Motor

1HP, 115V, 1Ph

1HP, 230V, 1Ph

18

1

109498

113274

Cord Set, 15Ft. (STD)

Cord Set, 15FT. (AU or Press. Cutout)

18A

1

103582

Compression Flange*

19

4

026322

Lockwasher, 5/16, Stainless

20

4

1-156-1

Hex Hd Capscrew, 

5/16-18 x 1.00”, Stainless

21

1

103503

Lifting Handle

24

1

039858

Capacitor Bracket

25

1

014270

Pipe Plug

26

4

1-140-1

Screw, 5/16-18, Stainless

27

1

107481

Snap Ring

28

2

084948

Sck. Hd Screw, 1/4-20, Stainless

29

5

070704

Flt. Hd. Screw, 1/4-20, Stainless

30

1

067556

Washer, Cutter, Stainless

32

1

105111A

Wire Assy, 10GA, Green

33

1

016660

Self Tapping Screw, #8-32, Stainless

34

1

061143

Snap Ring

36

A/R

-------

LOCTITE 609

37

A/R

-------

LOCTITE 242

39

A/R

-------

Permatex 2C

41

A/R

-------

Grease, Food-Grade, 450 deg. MP

48

1

105197

Snap Ring

ITEM

QTY

PART NO.

DESCRIPTION

49

1

2-31051-224 O-Ring

50

1

103760

113271

Terminal Block (STD)

Terminal Block (AU or Press. Cutout)

51

1

625-02117

Sleeving

PRESSURE CUTOUT SWITCH OPTION

52

1

103759

Block, Terminal, 2Pin

53

1

113281

Switch, Pressure Cutout

54

1

105147B

Wire, Jumper, 10”

55

1

105149

Wire Jumper

56

1

625-00163

Connector, Wire

57

1

2-31051-224 O-Ring

58

1

105197

Snap Ring

60

2

1-156-1

Hex Hd Capscrew, 

5/16-18 x 1.00” Stainless

61

2

26322

Lockwasher, 5/16

62

1

111203

Reducer Bushing

1.00” NPT x .25” NPT

63

1

111202

Elbow. Pipe, 1.00” NPT

64

1

111201

Nipple, Pipe

1.00” NPT x 1.50” Lg

65

1

111204

Reducer Bushing,

1.50” NPT x 1.00” NPT

“AU*” LEVEL CONTROL OPTION

66

1

103759

113272

Terminal Block, 2 pin - Single

Terminal Block, 5 pin - AUF or AUE

67

1

103746

113273

Float Switch - Single

Float Switch - Dual, AUF

68

1

3

105147B

105147A

Jumper Wire, 10” - Single

Jumper Wire, 10” - Dual

69

1

105149

105149A

Jumper Wire - Single

Jumper Wire - Dual

70

1

625-00163

Wire Connector

71

1

2-31051-224 O-Ring

72

1

105197

Snap Ring

74

2

1-156-1

Hex Hd Screw, 5/16-18 x 1.00” Stainless

75

2

026322

Lockwasher, 5/16

76

1

090516

Cord Clip, Lined

77

1

20-12-1

Lockwasher, #10

78

1

11-17-1

Sck Hd Screw, 10-32 x .375” Lg

79

1

121676-M

ESPS-150 Level Control

Contact your local Distributor or the Factory for other seal 

materials, cord lengths and other optional equipment.

(*) Included with cord set item #18.

Summary of Contents for Barneb PS SGPC Series

Page 1: ...ement program product changes may occur As such Crane Pumps Systems reserves the right to change product without prior written notification 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax 937 773 7157 Fax 905 457 2650 www cranepumps com Form No 108093 Rev P TM ultra Series SGPC 1 0 HP 1750 RPM 60 Hz SUPERSEDED Some parts may ...

Page 2: ...G Keep clear of suction and discharge openings DO NOT insert fingers in pump with power connected Make sure lifting handles are securely fastened each time before lifting Do not operate pump without safety devices in place Always replace safety devices that have been removed during service or repair Do not exceed manufacturers recommendation for maximum performance as this could cause the motor to...

Page 3: ...is the Barnes UltraGRIND grinder pump station The basin collects all wastewater from the house The solids in the sewage are then ground to a small size suitable for pumping in the slurry The grinder pump generates sufficient pressure to pump this slurry from your home to the wastewater plant Power Failure Your grinder pump cannot dispose of wastewater or provide an alarm signal without electrical ...

Page 4: ...m 15 Ft 4 6m Std or 30 Ft 9m Cord Custom Molded Quick Connected for sealing and strain relief CORD AU CVP CSA UL Approved 12 5 Type SOW L CSA UL Approved 12 3 Type SOW SPEED 1750 RPM 60Hz UPPER BEARING Design Single Row Ball Lubrication Oil Load Radial LOWER BEARING Design Single Row Ball Lubrication Oil Load Radia Thrust MOTOR Design Oil Filled Squirrel Cage Induction Insulation Class B Type Perm...

Page 5: ...5 inches mm SGPC1024AUF SGPC1024AUE ESPS 150 Level Control Sold Separatly ...

Page 6: ...24CVP 1 240 1 D 9 2 17 5 2 3 9 7 PUMP MODEL HP 60Hz BREAKER SIZE CORD SIZE CODE TYPE CORD O D 02 5 in mm CORD LENGHT Ft m SGPC1014L 1 30 AMP 12 3 SOW 61 15 5 15 4 6 SGPC1024L 1 25 AMP 12 3 SOW 61 15 5 15 4 6 SGPC1024AU 1 25 AMP 12 5 SOW 71 18 30 9 SGPC1024AU 1 25 AMP 12 3 SOW 61 15 5 30 9 SGPC1024CVP 1 25 AMP 12 5 SOW 71 18 15 4 6 Winding Resistance 5 measured from terminal block Pump rated for op...

Page 7: ...he pump be installed and tested before the long term storage begins such installa tion will be allowed provided 1 The pump is not installed under water for more than one 1 month 2 Immediately upon satisfactory completion of the test the pump is removed thoroughly dried repacked in the original shipping container and placed in a temperature controlled storage area SERVICE CENTERS For the location o...

Page 8: ... float is attached to the piping at the factory or shipped loose Hardware is provided for mounting the ON OFF float typically to a 1 25 NPT pipe Other various mounting methods can be used so long the ON OFF float is 1 Securely mounted to a fixed object such as pipe brackets etc 2 Has a three to three and one half inch tether length 3 Basin wall pump inflow etc DO NOT obstruct float operation 4 Bel...

Page 9: ...ed to as an inherent overheating protector and operates on the combined effect of temperature and current This means that the overload protector will trip out and shut the pump off if the windings become too hot or the load current becomes too high It will then automatically reset and start the pump after the motor cools to a safe temperature In the event of an overload the source of this conditio...

Page 10: ...10 FIGURE 5 Single Phase 240 Volt AC with Closed Valve Protection CVP Single phase 240 Volt AC AU Series Wiring Schematic For Pumps with Dual Hole Motor Housing ...

Page 11: ...ny obstruction 9 Loosen union slightly to allow trapped air to escape Verify that turn off level of switch is set so that the suction is always flooded Clean vent hole 10 Remove examine for damage Replace pump stator if required 11 Repair fixtures as required to eliminate leakage 12 Check pump temperature limits fluid temperature 13 Replace portion of discharge pipe with flexible connector 14 Turn...

Page 12: ...ower Guide Bracket Assembly 4 1 112354 Check Valve Upper Moveable 5 1 116470 Street Elbow Pump NOT included under these part numbers The Moveable Assembly will be factory assembled to the pump when a Basin Package system is ordered MOVEABLE ASSEMBLY P N 116601 For SGPC UltraCAV Grider Pump with C Channel Rail ...

Page 13: ...13 FIGURE 7 ...

Page 14: ...242 39 A R Permatex 2C 41 A R Grease Food Grade 450 deg MP 48 1 105197 Snap Ring ITEM QTY PART NO DESCRIPTION 49 1 2 31051 224 O Ring 50 1 103760 113271 Terminal Block STD Terminal Block AU or Press Cutout 51 1 625 02117 Sleeving PRESSURE CUTOUT SWITCH OPTION 52 1 103759 Block Terminal 2Pin 53 1 113281 Switch Pressure Cutout 54 1 105147B Wire Jumper 10 55 1 105149 Wire Jumper 56 1 625 00163 Connec...

Page 15: ...15 NOTES ...

Page 16: ... A RETURNED GOODS AUTHORIZATION CONTACT YOUR LOCAL CRANE PUMPS SYSTEMS INC DISTRIBUTOR Products Returned Must Be Cleaned Sanitized Or Decontaminated As Necessary Prior To Shipment To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty If...

Reviews: