21
MODEL
NO
PART
NO
HP
VOLT
PH
Hz
RPM
(Nom)
NEMA
START
CODE
FULL
LOAD
AMPS
SERVICE
FACTOR
SERVICE
FACTOR
AMPS
LOCKED
ROTOR
AMPS
CORD
P/N ▲
CORD
SIZE
CORD
O.D.
WINDING
RESISTANCE
MAIN - - START
4SHVBA
Pump
4SHVBA5074
139982*
5.0
208
1
60
1750
D
27.2
1.2
35.6
99.9
125498
8/4 - 18/4
1.12 ± .02
0.50 - 2.66
230
F
25.4
1.2
30.2
112.4
125496
12/4 - 18/4
.86 ± .02
0.50 - 2.66
4SHVBA50N4
139983*
5.0
208
3
60
1750
J
15.8
1.2
18.7
82.4
125496
12/4 - 18/4
.86 ± .02
0.72
230
15.0
1.2
17.2
92.4
125496
12/4 - 18/4
.86 ± .02
0.72
460
7.5
1.2
8.6
46.2
125497
12/4 - 18/4
.86 ± .02
2.88
4SHVBA5054
139984*
5.0
575
3
60
1750
J
6.0
1.2
6.9
37.0
125497
12/4 - 18/4
.86 ± .02
4.32
4SHVBA75N4
138953
7.5
208
3
60
1750
H
23.8
1.2
28.5
105.9
125496
12/4 - 18/4
.86 ± .02
0.43
230
23.7
1.2
27.2
123.6
125496
12/4 - 18/4
.86 ± .02
0.43
460
11.9
1.2
13.6
61.8
125497
12/4 - 18/4
.86 ± .02
1.72
4SHVBA7554
138954
7.5
575
3
60
1750
H
9.5
1.2
10.9
49.4
125497
12/4 - 18/4
.86 ± .02
2.69
4SHVBA100N4
138955
10.0
208
3
60
1750
E
32.2
1.2
41.4
105.9
125498
8/4 - 18/4
1.12 ± .02
0.43
230
29.8
1.2
35.6
123.6
125498
8/4 - 18/4
1.12 ± .02
0.43
460
14.9
1.2
17.8
61.8
125497
12/4 - 18/4
.86 ± .02
1.72
4SHVBA10054
138956
10.0
575
3
60
1750
E
11.9
1.2
14.2
49.4
125497
12/4 - 18/4
.86 ± .02
2.69
Moisture and Temperature sensor leads are integral to power cord.
Winding Resistance ± 7.5%
Winding resistance measured in OHMS @ 25°C (Between Lines) at motor leads.
Pump rated for operation at ± 10% voltage at motor.
▲ Cord Suffi x: XF - 50 Feet, XJ - 75 Feet, or XL - 100 Feet
▲ Cord sold separately (After March-2016 ONLY). Pumps built Before March-2016 refer to Cord Assembly Kit, see page 28.
* Select impeller diameter when ordering.
CHART ‘F’