18
MODEL
NO
PART
NO
HP
VOLT
PH
Hz
RPM
(Nom)
NEMA
START
CODE
FULL
LOAD
AMPS
1.2 SERVICE
FACTOR
AMPS
LOCKED
ROTOR
AMPS
CORD
P/N
▲
CORD
SIZE
CORD
O.D.
WINDING
RESISTANCE
MAIN - - START
3SHMP
Pump
3SHMP2074
133681
2.0
208
1
60
1750
G
10.4
12.1
59.1
125496
12/4 - 18/4
.86 ± .02
0.88 - 2.14
230
J
10.7
11.9
66.3
.86 ± .02
0.88 - 2.14
3SHMP20N4
133682
2.0
208
3
60
1750
P
7.4
8.3
58.2 / 65.8
125496
12/4 - 18/4
.86 ± .02
1.08
230
7.4
8.0
125496
12/4 - 18/4
.86 ± .02
1.08
460
3.7
4.0
32.9
125497
12/4 - 18/4
.86 ± .02
4.32
3SHMP2054
133683
2.0
575
3
60
1750
T
3.9
4.2
37.0
125497
12/4 - 18/4
.86 ± .02
4.32
3SHMP3074
133684
3.0
208
1
60
1750
D
14.9
18.5
59.1
125496
12/4 - 18/4
.86 ± .02
0.88 - 2.14
230
F
14.1
16.5
66.3
.86 ± .02
0.88 - 2.14
3SHMP30N4
133685
3.0
208
3
60
1750
K
9.7
11.4
58.2 / 65.8
125496
12/4 - 18/4
.86 ± .02
1.08
230
9.2
10.6
125496
12/4 - 18/4
.86 ± .02
1.08
460
4.6
5.3
32.9
125497
12/4 - 18/4
.86 ± .02
4.32
3SHMP3054
133686
3.0
575
3
60
1750
N
4.5
4.9
37.0
125497
12/4 - 18/4
.86 ± .02
4.32
3SHMP5074
133687
5.0
208
1
60
1750
D
27.2
35.6
99.9
125498
8/4 - 18/4
1.12 ± .02
0.50 - - 2.66
230
F
25.4
30.2
112.4
1.12 ± .02
0.50 - - 2.66
3SHMP50N4
133688
5.0
208
3
60
1750
J
15.8
18.7
82.4 / 92.4
125496
12/4 - 18/4
.86 ± .02
0.72
230
15.0
17.2
125496
12/4 - 18/4
.86 ± .02
0.72
460
7.5
8.6
46.2
125497
12/4 - 18/4
.86 ± .02
2.88
3SHMP5054
133689
5.0
575
3
60
1750
J
6.0
6.9
37.0
125497
12/4 - 18/4
.86 ± .02
4.32
3SHMP
A
Pump
3SHMPA3074
137498
3.0
208
1
60
1750
D
14.9
18.5
59.1
125496
12/4 - 18/4
.86 ± .02
0.88 - 2.14
230
F
14.1
16.5
66.3
3SHMPA30N4
137499
3.0
208
3
60
1750
K
9.7
11.4
58.2 / 65.8
125496
12/4 - 18/4
.86 ± .02
1.08
230
9.2
10.6
1.08
460
4.6
5.3
32.9
125497
4.32
3SHMPA3054
137500
3.0
575
3
60
1750
N
4.5
4.9
37.0
125497
12/4 - 18/4
.86 ± .02
4.32
3SHMPA5074
137501
5.0
208
1
60
1750
D
27.2
35.6
99.9
125498
8/4 - 18/4
1.12 ± .02
0.50 -- 2.66
230
F
25.4
30.2
112.4
0.50 -- 2.66
3SHMPA50N4
137502
5.0
208
3
60
1750
J
15.8
18.7
82.4 / 92.4
125496
12/4 - 18/4
.86 ± .02
0.72
230
15.0
17.2
0.72
460
7.5
8.6
46.2
125497
2.88
3SHMPA5054
137503
5.0
575
3
60
1750
J
6.0
6.9
37.0
125497
12/4 - 18/4
.86 ± .02
4.32
3SHMPA75N4
137940
7.5
208
3
60
1750
H
23.8
28.5
105.9 / 123.6
125496
12/4 - 18/4
.86 ± .02
0.43
230
23.7
27.2
0.43
460
11.9
13.6
61.8
125497
1.72
3SHMPA7554
137941
7.5
575
3
60
1750
H
9.5
10.9
49.4
125497
12/4 - 18/4
.86 ± .02
2.69
Moisture and Temperature sensor leads are integral to power cord.
Winding Resistance ± 7.5%
Winding resistance measured in OHMS @ 25°C (Between Lines) at motor leads.
Pump rated for operation at ± 10% voltage at motor.
▲ Cord Suffi x: XF - 50 Feet, XJ - 75 Feet, or XL - 100 Feet
▲ Cord sold separately (After March-2016 ONLY). Pumps built Before March-2016 refer to Cord Assembly Kit, see page 28.
CHART ‘C’