17
MODEL
NO
PART
NO
HP
VOLT
PH
Hz
RPM
(Nom)
NEMA
START
CODE
FULL
LOAD
AMPS
1.2 SERVICE
FACTOR
AMPS
LOCKED
ROTOR
AMPS
CORD
P/N
▲
CORD
SIZE
CORD
O.D.
WINDING
RESISTANCE
MAIN - - START
3SHVRA Pump
3SHVRA2074
138194
2.0
208
1
60
1750
G
10.4
12.1
59.1
125496
12/4 - 18/4
.86 ± .02
0.88 -- 2.14
230
60
1750
J
10.7
11.9
66.3
125496
12/4 - 18/4
.86 ± .02
0.88 -- 2.14
3SHVRA20N4
138195
2.0
208
3
60
1750
P
7.4
8.3
58.2
125496
12/4 - 18/4
.86 ± .02
1.08
230
60
1750
7.4
8.0
65.8
125496
12/4 - 18/4
.86 ± .02
1.08
460
60
1750
3.7
4
32.9
125497
12/4 - 18/4
.86 ± .02
4.32
3SHVRA2054
138196
2.0
575
3
60
1750
T
3.9
4.2
37.0
125497
12/4 - 18/4
.86 ± .02
4.32
3SHVRA3074
138197
3.0
208
1
60
1750
D
14.9
18.5
37.0
125496
12/4 - 18/4
.86 ± .02
0.88 -- 2.14
230
60
1750
F
14.1
16.5
66.3
125496
12/4 - 18/4
.86 ± .02
0.88 -- 2.14
3SHVRA30N4
138198
3.0
208
3
60
1750
K
9.7
11.4
58.2
125496
12/4 - 18/4
.86 ± .02
1.08
230
60
1750
9.2
10.6
65.8
125496
12/4 - 18/4
.86 ± .02
1.08
460
60
1750
4.6
5.3
32.9
125497
12/4 - 18/4
.86 ± .02
4.32
3SHVRA3054
138199
3.0
575
3
60
1750
N
4.5
4.9
37.0
125497
12/4 - 18/4
.86 ± .02
4.32
3SHVRA5074
138200
5.0
208
1
60
1750
D
27.2
35.6
99.9
125498
8/4 - 18/4
1.12 ± .02
0.50 -- 2.66
230
60
1750
F
25.4
30.2
112.4
125498
12/4 - 18/4
.86 ± .02
0.50 -- 2.66
3SHVRA50N4
130201
5.0
208
3
60
1750
J
15.8
18.7
82.4
125496
12/4 - 18/4
.86 ± .02
0.72
230
60
1750
15
17.2
92.4
125496
12/4 - 18/4
.86 ± .02
0.72
460
60
1750
7.5
8.6
46.2
125497
12/4 - 18/4
.86 ± .02
2.88
3SHVRA5054
130202
5.0
575
3
60
1750
J
6
6.9
37.0
125497
12/4 - 18/4
.86 ± .02
4.32
3SHVRA75N4
130203
7.5
208
3
60
1750
H
23.8
28.5
105.9
125496
12/4 - 18/4
.86 ± .02
0.43
230
60
1750
23.7
27.2
123.6
125496
12/4 - 18/4
.86 ± .02
0.43
460
60
1750
11.9
13.6
61.8
125497
12/4 - 18/4
.86 ± .02
1.72
3SHVRA7554
138204
7.5
575
3
60
1750
H
9.5
10.9
49.4
125497
12/4 - 18/4
.86 ± .02
2.69
Moisture and Temperature sensor leads are integral to power cord.
Winding Resistance ± 7.5%
Winding resistance measured in OHMS @ 25°C (Between Lines) at motor leads.
Pump rated for operation at ± 10% voltage at motor.
▲ Cord Suffi x: XF - 50 Feet, XJ - 75 Feet, or XL - 100 Feet
▲ Cord sold separately (After March-2016 ONLY). Pumps built Before March-2016 refer to Cord Assembly Kit, see page 28.