SECTION B: GENERAL INFORMATION

B-1) Introduction:

Barnes Break Away Fittings (BAF) are precision engineered 
and manufactured of the highest quality castings. Each one 
is individually inspected by a Quality Assurance Program to 
allow years of continuous service.
Through proper installation this unit will provide superior 
service. This manual will provide basic information for 
installation, maintenance, and repair.

B-2)  Receiving:

Upon receiving this unit, inspect it for damage or shortages. 
If damage has occurred, fi le a claim immediately with the 
delivery company that delivered your equipment. If the 
manual is removed from the crating, do not lose or misplace 
it.

B-3) Storage:

This unit has been packaged and protected for shipping and 
indoor storage. If it is to be stored outside for an extended 
period, additional protection must be added.

Short Term - For best results, retain BAF factory assembled, 
in a dry atmosphere with constant temperature for up to six 
(6) months.

Long Term - Any length of time exceeding six (6) months, 
but not more than twenty four (24) months. The units should 
be stored in a temperature controlled area, a roofed over 
walled enclosure that provides protection from the elements 
(rain, snow, wind blown dust, etc..), and whose temperature 
can be maintained b40 deg. F and +120 deg. F. 
If extended high humidity is expected to be a problem, all 
exposed parts should be inspected before storage and all 
surfaces that have the paint scratched, damaged, or worn 
should be recoated. All surfaces should then be sprayed 
with a rust-inhibiting oil.

B-4) Service Centers:

For the location of the nearest Barnes Service Center, check 
your Barnes representative or Crane Pumps & Systems, Inc., 
Service Department in Piqua, Ohio, telephone (937) 778-8947 
or Crane Pumps & Systems Canada Inc., Bramton, Ontario 
(905) 457-6223.

SECTION: C  INSTALLATION
C-1)  Location:

The Break Away Fitting Model BAF-6, when used in 
conjunction with Barnes Pumps 6” Submersible Sewage 
Pumps (Series 6SE) is recommended for operation in 
a wet well, tank, or lift station. The Non-Sparking Break 
Away Fitting Model BAF-E6, when used in conjunction with 
Barnes Pumps 6” Explosion Proof Submersible Sewage 
Pumps (Series 6XSE) is recommended for operation in a 
non-hazardous or Class 1, Group D, Division 1 hazardous 
location wet well, basin, or lift station.

C-2) Design Layout:

Models BAF-6 and BAF-E6 assembled with pumps listed 
in Section C-1 can be installed through access covers with 
sizes as listed in Table 1. 

TABLE 1 - ACCESS COVER DATA

COVER TYPE

COVER SIZE

FIGURE

Simplex

36” (914mm) x

30” (762mm)

1,2 and 3

Duplex (Standard 
Piping)

36” (914mm) x

60” (1524mm)

1,2 and 4

Duplex (Special 
Piping)

36” (914mm) x

54” (1372mm)

1,2 and 5

Figures 1 through 5 provide clearance dimensions, guide 
pipe locations, and proposed anchor bolt locations at the 
access cover opening. It is recommended that the guide 
rail cap be installed with 3/8 inch stainless steel anchors.

Figures 1 and 2 provide the required anchor bolt locations 
for the stationary elbow to be installed with four anchor 
bolts set in a metal sleeve and accurately set into concrete. 
Hook bolts can be used, however, they are more diffi cult to 
locate in concrete. Use required shims under the stationary 
elbow base to level the horizontal fl ange and then grout 
under the base as required. A 30 day concrete cure is 
required before a full load can be applied to the anchor 
bolts. Design the anchor bolts for 1.6 kip uplift per bolt.

The 2” schedule 40 guide rail pipes must be plumbed after 
mounting on stationary base elbow plugs. Pipe material 
may be galvanized steel or stainless steel (optional from 
manufacturer or supplied by customer).

C-3)  Intermediate Support Assembly:

Whenever the guide pipe lengths exceed 13 feet, an 
optional intermediate guide rail support bracket should be 
used (see Figure 6). The intermediate guide rail support 
brackets may be supported from the vertical discharge 
pipe.

C-4)  Installing Pump Body To Break Away Fitting:

(See Figure 7) These instructions apply to all BARNES 
pumps with a 125 lb. fl ange horizontal discharge on volute. 
All parts for standard and non-sparking BAF’s are the same 
except for moveable assembly. BAF-6 standard assemblies 
use a cast iron moveable assembly and BAF-E6 
non-sparking assemblies use a bronze moveable assembly.
Position one gasket (4) between the moveable assembly (1) 
comprised of Moveable (1A) and O-Ring (1B) and the pump 
body discharge fl ange. Attach the discharge fl ange to the 
moveable assembly with 8 hex head bolts (5), 8 split lock 
washers (6), and 8 hex nuts (7). Torque each bolt to 
105/115 ft. lbs.

IMPORTANT ! - BOLTS MUST BE INSTALLED 
WITH HEADS ON SLIDE ASSEMBLY. BOTTOM 2 
BOLT HEADS FIT IN RECESSES ON SLIDE. 

Summary of Contents for 091550

Page 1: ...uct improvement program product changes may occur As such Crane Pumps Systems reserves the right to change product without prior written notification 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax 937 773 7157 Fax 905 457 2650 www cranepumps com Form No 090105 Rev E Models BAF 6 Standard P N 091550 BAF E6 Non Sparking P N 091...

Page 2: ...e sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety devices in place Always replace safety devices that have been removed during service or repair Secure the pump in its operating position so it can not tip over fall or slide DO NOT exceed manufacturers recommendation for maximum performance as this could cause the motor to overheat DO NOT remov...

Page 3: ...tions classified as Hazardous location Class 1 Group D Division 1 and or non hazardous locations where it is necessary to remove a pump from service and reinstall the pump without maintenance personnel entering the pit to unbolt the pump flanges STATIONARY ELBOW Cast iron ASTM A48 Class 30 MOVABLE FITTING Bronze 81 3 7 9 GUIDE RAIL CAP Bracket 304 Stainless steel Plugs Ductile iron ASTM A536 84 HARD...

Page 4: ...4 inches mm Figure 1 Figure 2 ...

Page 5: ...s or Class 1 Group D Division 1 hazardous location wet well basin or lift station C 2 Design Layout Models BAF 6 and BAF E6 assembled with pumps listed in Section C 1 can be installed through access covers with sizes as listed in Table 1 TABLE 1 ACCESS COVER DATA COVER TYPE COVER SIZE FIGURE Simplex 36 914mm x 30 762mm 1 2 and 3 Duplex Standard Piping 36 914mm x 60 1524mm 1 2 and 4 Duplex Special ...

Page 6: ...6 Figure 5 Duplex Installation Optional Figure 4 Duplex Installation Standard Figure 3 Simplex Installation ...

Page 7: ... AND REPAIR D 1 Maintenance After pump is lifted for inspection it is recommended any foreign material be flushed from moveable fitting guide plugs and stationary base elbow face before replacement in wet well D 2 Repair NOTE All item numbers in refer to Figure 7 D 2 1 Moveable Assembly To install a new o ring in moveable assembly 1 completely remove o ring 1B and thoroughly clean groove recess in m...

Page 8: ...8 Figure 6 ...

Page 9: ...9 Figure 7 ...

Page 10: ...0 Lg Stainless 6 8 20 16 1 Split Lock Washer 75 Stainless 7 8 15 7 1 Hex Nut 75 10 Stainless BAF E6 P N 091551 ITEM QTY PART No DESCRIPTION 1 1 090084 Moveable Fitting Assembly 1A 1 090080 Moveable Bronze 1B 1 090085 O Ring 6 50 I D Buna N 2 1 090088 Stationary Base Elbow Assembly 2A 1 090087 Stationary Base Elbow Cast Iron Class 30 2B 2 090086 Guide Plug Cast Iron Class 30 2C 2 1 93 1 Sk Hd Screw...

Page 11: ...25Lg Stainless 9H 4 20 14 1 Split Lockwasher 375 Stainless 9I 4 15 23 1 Hex Nut 375 16 Stainless 9J 1 090107 Bracket Stainless 9K 1 090106 Clamp Stainless 9L 2 1 36 1 Hex Hd Screw 375 16 x 1 25Lg Stainless CHAIN Not Shown 10A A R 625 01582 312 Dia Chain Galvanized 10B A R 625 01583 375 Dia Chain Galvanized 11A A R 625 00828 375 Dia Cold Shut Zinc Plated 11B A R 625 00826 437 Dia Cold Shut Zinc Pla...

Page 12: ...OSE RESULTING FROM SYSTEMS ANALYSES AND EVALUATIONS WE CONDUCT WILL BE BASED ON OUR BEST AVAILABLE EXPERIENCE AND PUBLISHED INDUSTRY INFORMATION SUCH RECOMMENDATIONS DO NOT CONSTITUTE A WARRANTY OF SATISFACTORY PERFORMANCE AND NO SUCH WARRANTY IS GIVEN This warranty shall not apply when damage is caused by a improper installation b improper voltage c lightning d excessive sand or other abrasive ma...

Page 13: ...13 Notes ...

Page 14: ...14 Notes ...

Page 15: ...E CITY STATE ZIP MODEL NO SERIAL NO PART NO BRAND IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty Complete the Warranty Registration Form and return to Crane Pumps Systems Inc Warranty Service Group If you have a claim under the provision of the warranty contact your local Crane Pumps Systems Inc Distributor ...

Page 16: ...CRANE PUMPS SYSTEMS INC WARRANTY SERVICE GROUP 420 THIRD STREET PIQUA OHIO 45356 U S A FOLD HERE AND TAPE DO NOT STAPLE PLACE STAMP HERE ...

Reviews: