![CRANE PUMPS & SYSTEMS DEMING 7365 Series Installation And Operation Manual Download Page 18](http://html.mh-extra.com/html/crane-pumps-and-systems/deming-7365-series/deming-7365-series_installation-and-operation-manual_2679260018.webp)
18
CHART ‘M’
MODEL NO
.
SIZE
IMP
. DIA.
INCHES
(MM)
HP
V
O
LT
PH
HZ
RPM
NEMA ST
AR
T
CODE
FULL LOA
D
AMPS
SER
VICE
FA
CT
OR
SER
VICE
FA
CT
OR
AMPS
LOCKED R
O
TO
R
AMPS
DRIVER FRAME
CORD P/N
▲
CORD SIZE
CORD O.
D
.
WINDING
RESIST
ANCE
7365-X55-37-30N
10DH
12.40 (315)
10
208
3
60
870
L
37.2
1.2
42.0
230.0
4
138317
8/4 - 18/4
1.12 ± .02
.199
230
38.6
1.2
42.2
4
138317
8/4 - 18/4
7365-X55-89-30N
10DH
12.40 (315)
10
460
3
60
870
L
19.3
1.2
21.1
115.0
4
138317
8/4 - 18/4
1.12 ± .02
.795
7365-X55-98-30N
10DH
12.40 (315)
10
575
3
60
870
L
15.4
1.2
16.9
92.0
4
138317
8/4 - 18/4
1.12 ± .02
1.27
7365-X55-38-30N
10DH
13.19 (335)
15
208
3
60
870
G
50.4
1.2
59.0
230.0
4
138317
8/4 - 18/4
1.12 ± .02
.199
230
48.4
1.2
55.6
4
138317
8/4 - 18/4
7365-X55-90-30N
10DH
13.19 (335)
15
460
3
60
870
G
24.2
1.2
27.8
115.0
4
138317
8/4 - 18/4
1.12 ± .02
.795
7365-X55-99-30N
10DH
13.19 (335)
15
575
3
60
870
G
19.4
1.2
22.2
92.0
4
138317
8/4 - 18/4
1.12 ± .02
1.27
7365-X55-31-30N
10DH
13.98 (355)
20
208
3
60
870
J
69.0
1.2
76.0
400.0
4
138318
6/4 - 18/4
1.14 ± .03
.121
230
75.1
1.2
79.0
4
138318
6/4 - 18/4
7365-X55-91-30N
10DH
13.98 (355)
20
460
3
60
870
J
37.6
1.2
41.1
200.0
4
138317
8/4 - 18/4
1.12 ± .02
.483
7365-X55-1A-30N
10DH
13.98 (355)
20
575
3
60
870
J
30.1
1.2
32.9
160.0
4
138317
8/4 - 18/4
1.12 ± .02
.77
7365-X55-32-30N
10DH
14.17 (360)
25
208
3
60
870
H
82.3
1.2
98.8
400.0
4
138319
2/4 - 18/4
1.47 ± .03
.121
230
84.0
1.2
94.5
4
138319
2/4 - 18/4
7365-X55-92-30N
10DH
14.17 (360)
25
460
3
60
870
H
42.0
1.2
47.2
200.0
4
138317
8/4 - 18/4
1.12 ± .02
.483
7365-X55-1B-30N
10DH
14.17 (360)
25
575
3
60
870
H
33.6
1.2
37.8
160.0
4
138317
8/4 - 18/4
1.12 ± .02
.77
7365*-X70-33-30N
10TB
**
208
3
60
1150
E
90.8
1.2
114.9
354.0
4
138319
2/4 - 18/4
1.47 ± .03
0.1
117
230
82.6
1.2
99.7
7365*-X70-93-30N
10TB
**
30.0
460
3
60
1150
E
41.3
1.2
49.9
177.0
4
138317
8/4 - 18/4
1.12 ± .02
0.4397
7365*-X70-1C-30N
10TB
**
30.0
575
3
60
1150
E
33.0
1.2
39.9
141.6
4
138317
8/4 - 18/4
1.12 ± .02
0.6857
7365*-X70-49-30N
10TB
12.01 (305)
40.0
230
3
60
1150
E
110.4
1.2
131.8
476.0
4
138319
2/4 - 18/4
1.47 ± .03
0.0819
7365*-X70-64-30N
10TB
12.01 (305)
40.0
460
3
60
1150
E
55.2
1.2
65.9
238.0
4
138318
6/4 - 18/4
1.14 ± .03
0.3277
7365*-X70-79-30N
10TB
12.01 (305)
40.0
575
3
60
1150
E
44.2
1.2
52.7
190.4
4
138317
8/4 - 18/4
1.12 ± .02
0.5443
▲
CORD SOLD SEP
ARA
TEL
Y. CORD SUFFIX: XF - 50 FEET
, XJ - 75 FEET
, OR XL
- 100 FEET
.
IMPOR
TANT !
1.)
MOISTURE
AND
TEMPERA
TURE SENSORS
MUST
BE CONNECTED
TO V
ALIDA
TE
THE CSA
LISTING.
2.)
A SPECIAL
MOISTURE SENSOR RELA
Y IS REQUIRED IN
THE CONTROL
P
ANEL
FOR PROPER OPERA
TION OF
THE MOISTURE SENSORS.CONT
ACT
CP&S FOR INFORMA
TION CONCERNING MOISTURE SENSING RELA
YS FOR
CUST
OMER SUPPLIED CONTROL
P
ANELS.
3.)
THESE PUMPS
ARE CSA
LISTED FOR PUMPING W
ATER
AND W
ASTEW
ATER.
DO NOT USE T
O PUMP
FLAMMABLE LIQUIDS
. NOT
SUIT
ABLE FOR ENVIRONMENTS CONT
AINING GASOLINE OR HEXANE.
4.)
INST
ALLA
TIONS SUCH
AS DECORA
TIVE FOUNT
AINS OR W
ATER FEA
TURES PROVIDED FOR VISUAL
ENJOYMENT
MUST
BE INST
ALLED IN
ACCORDANCE WITH
THE NA
TIONAL
ELECTRIC CODE
ANSI/NFP
A 70
AND/OR
THE
AUTHORITY
HA
VING JURISDICTION.
THIS PUMP
IS NOT
INTENDED FOR USE IN SWIMMING POOLS, RECREA
TIONAL
W
ATER P
ARKS, OR INST
ALLA
TIONS IN WHICH HUMAN CONT
ACT
WITH PUMPED MEDIA
IS
A COMMON OCCURRENCE.
5.)
A
NON-SP
ARKING
BREAKA
W
AY
FITTING MUST
BE USED
TO V
ALIDA
TE
THE EXPLOSION PROOF LISTING.
6.)
WINDING RESIST
ANCE
± 7.5%. WINDING RESIST
ANCE MEASURED IN OHMS @ 25°C (BETWEEN LINES)
AT
MOT
OR LEADS.
7.)
PUMP
RA
TED FOR OPERA
TION
AT
± 10% VOL
TAGE
AT
MOT
OR.
**
SELECT