5.3 Input Wiring
900-R Installation Manual
IN1
and
IN2
are dedicated as a
Door Contact
and a
Request to Exit button
when 900-R is
used in an access control system.
When using Supervised input they must satisfy the requirements of supervising Host access
control systems.
Figure 5-3 900-R Input Wiring
In Supervised mode, any input terminals that are not used
MUST
be
CLOSED
.
One twisted pair per input is required, 30 ohms max, 24AWG (Belden8740 or equivalent).
Note: The resistor value specified is for example value.
5.4 Reader Interface Wiring
The 900-R provides a reader interface connection for a Wiegand style reader. To fully utilize
each reader port, a 5-conductor cable (18AWG) is required. For reader power selection, see
per
Figure 4-6
.
Figure 5-4
Reader Interface Wiring
11