4.7 Offline Mode Setting
There are four modes which can be set for when communication is lost
among the modules. The mode is set by S1 and S2 of the SW1 settings.
4.7.1 Facility Code Only - 5 Second
900-R Installation Manual
In this mode, the cardholder will be granted access with a card with the correct facility code.
The facility code is set by SW2. When access is granted, the door will remain unlocked for 5
seconds. Use of the request to exit will also be granted.
4.7.2 Facility Code Only - 10 Seconds
This mode is the same as above with the exception of the unlock time being increased to 10
seconds.
4.7.3 No Action Mode
All cardholders will be denied. Use of the request to exit will be granted, unlocking the door
for 5 seconds.
4.7.4 Door Unlock Mode
The door will remain unlocked until normal communication is restored.
SW1-S1
SW1-S2
Selection
OFF
OFF
Facility Code Only (5S)
OFF
ON
Facility Code Only (10S)
ON
OFF
No-Action
ON
ON
Door Unlock