ON SCREEN MENU
ENCODER SENSITIVITY
Used to adjust sensitivity of the encoder.
KEYS LIGHT
Used to enable/disable Keys Light.
TALLY UMD SOURCE
Used to select Tally and UMD Source. Values are: GPIO, RS-232, TSL. Tally can be displayed on UMD and/or
with squares at the bottom of the image.
EQUIPMENT ID
Used to set Equipment ID to identify it for Ethernet communications.
For TSL, the equipment ID is the Offset on the first UMD and Tally that will be used.
For example: To control 2 equipments with 8 inputs, first equipment will have ID 01 and the second equipment
will have ID 09.
14
DISPLAY DATA CONV
Display Data Conversion
is used to select the mode of data conversion form YCbCr to RGB for the display.
Values are REC 601, REC 709. Default Value is REC 709.
Fn KEYS MODE
Used to configure direct keys. Values are: IMAGE, AUDIO, MARKERS, SCOPES, MULTI, LAYOUT, USER.
These options locate adjustments in direct keys. USER option is used to select customized the direct keys.
Customization of F1 to F11 direct keys explained in pag 3 of this manual.
SYSTEM MENU
15
01
IMAGE0
USER
ON
TSL
ON
ON
Small
00
00
No
Rec709
NO
NO
Backlight
Equipment ID
Encoder Sensitivity
Fn Keys Mode
Keys Light
Tally UMD Source
Display on UMD
Display Squares
OSD Size
OSD x/y Position
OSD Transparency
Start Calibration
Display Data Conv
Factory Default
Update Firmware
1. Select the
SYSTEM
menu and press the encoder to enter.
2. Press Menu Encoder to select the adjustment to be modified
(adjustment will be marked in white), and use the encoder to adjust
the value. Press Menu Encoder again to Exit adjustment
(adjustment will be marked in grey), and continue navigating.
3. Press
ESC
button to move back to main menu.
BACKLIGHT
Used to adjust backlight value (form 0 to 15). The backlight brightness affect to LED Backlight and not to signal.
SFX-3G By Craltech
IMAGE
COLOR
AUDIO
MARKERS
SCOPES
INPUT
DISPLAY
ALARMS
NETWORK
SYSTEM
OSD SIZE
Used to select OSD size. Values are: Small, Large
OSD x/y POSITION
Used to select OSD position.
OSD TRANSPARENCY
Used to select OSD Transparency.
UPDATE FIRMWARE
Used to update the monitor.
FACTORY DEFAULT
This option is used to reset the monitor.
NOTE: This option will set Equipment ID to 01 (Factory value).
START CALIBRATION
Connect the Monitor to Light illusion software to create a table of the monitor.
Version 1
Updated 09/09/2020
CM185SL-3G