Location of the Air Compressor

Locate the air compressor in a clean, dry and well 
ventilated area. 

The air compressor should be located at least 12" 
(30.5 cm) away from the wall or other obstructions that 
will interfere with the flow of air. 

The air compressor pump and shroud are designed 
to allow for proper cooling. The ventilation openings 
on the compressor are necessary to maintain proper 
operating temperature. Do not place rags or other 

Grounding Instructions (Fig. A)

WARNING:

 

Risk of Electrical Shock. In the event 

of a short circuit, grounding reduces the risk 
of shock by providing an escape wire for the 
electric current. This air compressor must be 

The portable air compressor is equipped with a cord having 

 1 

1. 

 1 

 with this unit contains a 

 2 

. This plug MUST be used with a 

 3 

.  

IMPORTANT: 

The outlet being used must be installed 

and grounded in accordance with all local codes and 
ordinances. 

2.  Make sure the outlet being used has the same 

configuration as the grounded plug. DO NOT USE AN 

3.  Inspect the plug and cord before each use. Do not use if 

4.  If these grounding instructions are not completely 

understood, or if in doubt as to whether the compressor 
is properly grounded, have the installation checked by a 

DANGER:

 

Risk of Electrical Shock. IMPROPER 

Do not modify the plug provided. If it does 
not fit the available outlet, a correct outlet 

Repairs to the cord set or plug MUST be made 

Extension Cords

If an extension cord must be used, be sure it is:

a 3-wire extension cord that has a 3-blade grounding 
plug, and a 3-slot receptacle that will accept the plug 
on the product

in good condition

no longer than 50' (15.2 m)

12

 gauge (AWG) or larger. (Wire size increases as gauge 

number decreases. 

10 

AWG and 

8

 AWG may also be 

used. DO NOT USE 

14

 OR 

16

 AWG.)

NOTICE:

 Risk of Property Damage. The use of an 

undersized extension cord will cause voltage to drop 
resulting in power loss to the motor and overheating. 
Instead of using an extension cord, increase the 
working reach of the air hose by attaching another 
length of hose to its end. Attach additional lengths of 

Voltage and Circuit Protection

Refer to 

Specifications 

for the voltage and minimum 

WARNING:

 Risk of Overheating.

 

Certain air 

compressors can be operated on a 15 amp circuit if 
the following conditions are met. 

Voltage supply to circuit must comply with the 

Circuit is not used to supply any other 


Circuit is equipped with a 15 amp circuit breaker 
or 15 amp time delay fuse. 

NOTE: 

If compressor is connected to a circuit 

protected by fuses, use only time delay fuses. Time 
delay fuses should be marked “D” in Canada and 
“T” in the US. 

If any of the above conditions cannot be met, or if operation 
of the compressor repeatedly causes interruption of the 
power, it may be necessary to operate it from a 20 amp 

OPERATION

WARNING: To reduce the risk of serious personal 
injury, turn unit off and disconnect it from 
power source before making any adjustments or 
removing/installing attachments or accessories.

 

WARNING:

  Risk of unsafe operation. Unit cycles 

automatically when power is on. When performing 
maintenance, you may be exposed to voltage sources, 
compressed air, or moving parts. Personal injuries can 
occur. Before performing any maintenance or repair, 
disconnect power source from the compressor and 

Know Your Air Compressor

READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE 
OPERATING YOUR UNIT. Compare the illustrations with 
your unit to familiarize yourself with the location of 
various controls and adjustments. Save this manual for 

Description of Operation (Fig. A)

Become familiar with these controls before operating 

Summary of Contents for CMXECXA0200341

Page 1: ...IR INSTRUCTIONMANUAL GUIDED UTILISATION MANUALDEINSTRUCTIONES CMXECXA0200341 1 888 331 4569 WWW CRAFTSMAN COM 1 888 899 0146 IFYOUHAVEQUESTIONSORCOMMENTS CONTACTUS POURTOUTEQUESTIONOUTOUTCOMMENTAIRE NOUSCONTACTER SITIENEDUDASOCOMENTARIOS CONTÁCTENOS ...

Page 2: ...sult in WARNING Read all safety warnings and all instructions WARNING WARNING 1 2 3 4 5 6 7 8 9 10 11 This instruction manual uses the following safety alert symbols and words to alert you to hazardous situations and your risk of personal injury or property damage To reduce the risk of injury read the instruction manual Never modify the product or any part of it Damage or personal injury could res...

Page 3: ...the air tank Breathing these contaminants can cause serious injury or death Air obtained directly from the compressor should never be used to supply air for human consumption In order to use air produced by this compressor for breathing suitable filters and in line safety equipment must be properly installed In line filters and safety equipment used in conjunction with the compressor must be capab...

Page 4: ...d Repairs attempted by unqualified personnel can result in serious injury or death by electrocution Any repairs required on this product should be performed by authorized service center personnel Electrical Grounding Failure to provide adequate grounding to this product could result in serious injury or death from electrocution See Grounding Instructions under Installation Make certain that the el...

Page 5: ...ompressor in a stable secure position to prevent accidental movement of the unit Never operate compressor on a roof or other elevated position Use additional air hose to reach high locations 125psig Glossary CFM SCFM Standard cubic feet per minute a unit of measure of PSIG Pounds per square inch gauge a unit of measure Code Certification Products that bear one or more of the following marks UL CUL...

Page 6: ...e increases as gauge number decreases 10 AWG and 8 AWG may also be used DO NOT USE 14 OR 16 AWG NOTICE Risk of Property Damage The use of an undersized extension cord will cause voltage to drop resulting in power loss to the motor and overheating Instead of using an extension cord increase the working reach of the air hose by attaching another length of hose to its end Attach additional lengths of...

Page 7: ...ir to enter the air tank When the air compressor reaches cut out pressure the check valve closes allowing air Motor Overload Protector not shown The motor has a thermal overload protector If the motor overheats for any reason the overload protector will shut off the motor The motor must be allowed to cool down before restarting 1 2 3 Plug the power cord into the correct branch 4 Set the On Off swi...

Page 8: ...on during use Under some conditions and duration of use noise from this NOTE All compressed air systems generate condensate that accumulates in any drain point e g tanks filter aftercoolers dryers This condensate contains lubricating oil and or substances which may be regulated and must be disposed of in accordance with local state and federal laws WARNING Risk of Bursting Water will condense in t...

Page 9: ...AN authorized WARNING Risk of Unsafe Operation Unit cycles automatically when power is on When servicing you may be exposed to voltage sources compressed air or moving parts Before servicing unit unplug or disconnect electrical supply to the air compressor bleed tank of pressure and allow the air compressor Storage Before you store the air compressor make sure you do 1 Review the Maintenance secti...

Page 10: ...y specific warranty information contained either in the packaging call the local company or see website for warranty information accessory please contact CRAFTSMAN call 1 888 899 0146 or 1 888 331 4569 Register online at www craftsman com registration CRAFTSMAN will repair or replace without charge any defects due to faulty materials or workmanship for one year from the date of purchase This warra...

Page 11: ...ssive amount of pressure drop when the accessory is used adjust the regulator following the instructions in the Description of Operation paragraph in the Operation Section NOTE Adjust the regulated pressure under flow conditions while accessory is being used Compressor is not supplying enough air to operate accessories Prolonged excessive use of air Decrease amount of air usage Compressor is not l...

Reviews: