background image

7

ENGLISH

MAINTENANCE

WARNING: To reduce the risk of serious personal 
injury, turn unit off and disconnect it from 
power source before making any adjustments or 
removing/installing attachments or accessories.

 

WARNING:

  

Risk of unsafe operation. Unit 

cycles automatically when power is on. 
When performing maintenance, you may be 
exposed to voltage sources, compressed air, 
or moving parts. Personal injuries can occur. 
Before performing any maintenance or repair, 
disconnect power source from the compressor 

Customer Responsibilities

Before each 

use

Daily or after 

each use

See tank 

warning 

label

Check Safety Valve

X

Drain Tank

X

Remove tank from 
service

X

1

How to Start

1. 

 to “On” and allow tank pressure 

to build. Motor will stop when tank pressure reaches 

2. 

 clockwise to increase pressure 

Fig. C

To Drain Tank (Fig. A, D)

WARNING:

 

Risk of Unsafe Operation. Air tanks 

contain high pressure air. Keep face and other 
body parts away from outlet of drain. Use 

draining as debris can be kicked up into face. 
WARNING: Risk from noise. Always wear proper 
hearing protection during use. Under some 
conditions and duration of use, noise from this 

NOTE: 

All compressed air systems generate condensate 

that accumulates in any drain point (e.g., tanks, filter, 
aftercoolers, dryers). This condensate contains lubricating 
oil and/or substances which may be regulated and must be 
disposed of in accordance with local, state, and federal laws 

WARNING: Risk of Bursting. Water will condense 
in the air tank. If not drained, water will corrode 
and weaken the air tank causing a risk of air 

NOTICE:

 Risk of Property Damage. Drain water 

from air tank may contain oil and rust which can 

1. 

 to “Off”.

2. 

 counterclockwise to set the 

3. 
4.  Place a suitable container under the drain valve to 

5. 

 allowing air to bleed from 

6. 

 on 

tank.

8

1- For more information, call our Customer Care Center at 1-888-899-0146
or 1-888-331-4569

.

NOTE:

 See

 

Operation 

To Check Safety Valve (Fig. C)

WARNING: Risk of Bursting. If the safety valve 
does not work properly, over-pressurization may 
occur, causing air tank rupture or an explosion. 
WARNING: Risk from Flying Objects. Always 
wear certified safety equipment: ANSI Z87.1 eye 

Before starting compressor, pull the ring on the safety 

 to make sure that the safety valve operates freely. If 

the valve is stuck or does not operate smoothly, it must be 

Summary of Contents for CMXECXA0200341

Page 1: ...IR INSTRUCTIONMANUAL GUIDED UTILISATION MANUALDEINSTRUCTIONES CMXECXA0200341 1 888 331 4569 WWW CRAFTSMAN COM 1 888 899 0146 IFYOUHAVEQUESTIONSORCOMMENTS CONTACTUS POURTOUTEQUESTIONOUTOUTCOMMENTAIRE NOUSCONTACTER SITIENEDUDASOCOMENTARIOS CONTÁCTENOS ...

Page 2: ...sult in WARNING Read all safety warnings and all instructions WARNING WARNING 1 2 3 4 5 6 7 8 9 10 11 This instruction manual uses the following safety alert symbols and words to alert you to hazardous situations and your risk of personal injury or property damage To reduce the risk of injury read the instruction manual Never modify the product or any part of it Damage or personal injury could res...

Page 3: ...the air tank Breathing these contaminants can cause serious injury or death Air obtained directly from the compressor should never be used to supply air for human consumption In order to use air produced by this compressor for breathing suitable filters and in line safety equipment must be properly installed In line filters and safety equipment used in conjunction with the compressor must be capab...

Page 4: ...d Repairs attempted by unqualified personnel can result in serious injury or death by electrocution Any repairs required on this product should be performed by authorized service center personnel Electrical Grounding Failure to provide adequate grounding to this product could result in serious injury or death from electrocution See Grounding Instructions under Installation Make certain that the el...

Page 5: ...ompressor in a stable secure position to prevent accidental movement of the unit Never operate compressor on a roof or other elevated position Use additional air hose to reach high locations 125psig Glossary CFM SCFM Standard cubic feet per minute a unit of measure of PSIG Pounds per square inch gauge a unit of measure Code Certification Products that bear one or more of the following marks UL CUL...

Page 6: ...e increases as gauge number decreases 10 AWG and 8 AWG may also be used DO NOT USE 14 OR 16 AWG NOTICE Risk of Property Damage The use of an undersized extension cord will cause voltage to drop resulting in power loss to the motor and overheating Instead of using an extension cord increase the working reach of the air hose by attaching another length of hose to its end Attach additional lengths of...

Page 7: ...ir to enter the air tank When the air compressor reaches cut out pressure the check valve closes allowing air Motor Overload Protector not shown The motor has a thermal overload protector If the motor overheats for any reason the overload protector will shut off the motor The motor must be allowed to cool down before restarting 1 2 3 Plug the power cord into the correct branch 4 Set the On Off swi...

Page 8: ...on during use Under some conditions and duration of use noise from this NOTE All compressed air systems generate condensate that accumulates in any drain point e g tanks filter aftercoolers dryers This condensate contains lubricating oil and or substances which may be regulated and must be disposed of in accordance with local state and federal laws WARNING Risk of Bursting Water will condense in t...

Page 9: ...AN authorized WARNING Risk of Unsafe Operation Unit cycles automatically when power is on When servicing you may be exposed to voltage sources compressed air or moving parts Before servicing unit unplug or disconnect electrical supply to the air compressor bleed tank of pressure and allow the air compressor Storage Before you store the air compressor make sure you do 1 Review the Maintenance secti...

Page 10: ...y specific warranty information contained either in the packaging call the local company or see website for warranty information accessory please contact CRAFTSMAN call 1 888 899 0146 or 1 888 331 4569 Register online at www craftsman com registration CRAFTSMAN will repair or replace without charge any defects due to faulty materials or workmanship for one year from the date of purchase This warra...

Page 11: ...ssive amount of pressure drop when the accessory is used adjust the regulator following the instructions in the Description of Operation paragraph in the Operation Section NOTE Adjust the regulated pressure under flow conditions while accessory is being used Compressor is not supplying enough air to operate accessories Prolonged excessive use of air Decrease amount of air usage Compressor is not l...