background image

34- FR

D24544

DANGER

RISQUE D'UNE UTILISATION DANGEREUSE

UNE UTILISATION DANGEREUSE 

DE VOTRE

COMPRESSEUR D'AIR

POURRAIT CAUSER

DES BLESSURES GRAVES OU LA MORT DE
L'UTILISATEUR OU D'AUTRES PERSONNES.

PRÉVENTION

RISQUE

LISEZ ATTENTIVEMENT 

TOUS LES INSTRUC-

TIONS ET 

LES AVERTISSEMENTS FIGURANT

DANS CE GUIDE.

FAMILIARISEZ-VOUS AVEC LE FONCTION-
NEMENT ET LES COMMANDES 

DU COM-

PRESSEUR D'AIR. 

GARDEZ LES ENFANTS, LES ANIMAUX DE
COMPAGNIE ET LES 

OBSTACLES ÉLOIGNÉS

DU COMPRESSEUR D'AIR À TOUT TEMPS. 

N'UTILISEZ PAS 

LE PRODUIT

LORSQUE VOUS

ÊTES FATIGUÉ OU SOUS L'INFLUENCE D'AL-
COOL OU DE DROGUES. 

RESTEZ ALERTE À TOUT MOMENT.

NE TENTEZ JAMAIS D'ANNULER LES
CARACTÉRISTIQUES DE SÉCURITÉ 

DE CE

PRODUIT. 

ASSUREZ-VOUS QU'UN EXTINCTEUR D'IN-
CENDIE EST DISPONIBLE DANS L'AIRE DE
TRAVAIL.

N'UTILISEZ PAS L'APPAREIL AVEC DES
PIÈCES BRISÉES, MANQUANTES OU NON
AUTORISÉES.

RISQUE DE DOMMAGES À LA PROPRIÉTÉ PENDANT LE TRANSPORT
DU COMPRESSEUR

DES FUITES OU DES DÉVERSEMENTS
D’HUILE PEUVENT SE PRODUIRE

ET

ENTRAÎNER DES RISQUES D’INCENDIE, OU
DES PROBLÈMES AUX VOIES RESPIRATOIRES,
DES BLESSURES GRAVES OU LA MORT. DES
FUITES D’HUILE ENDOMMAGENT LES TAPIS,
LA PEINTURE ET TOUTE AUTRE SURFACE DES
VÉHICULES OU DES REMORQUES. 

TOUJOURS PLACER LE COMPRESSEUR SUR
UN TAPIS DE PROTECTION POUR ÉVITER

L’ENDOMMAGEMENT DU VÉHICULE PAR DES
FUITES. RETIRER LE COMPRESSEUR DU
VÉHICULE IMMÉDIATEMENT À L’ARRIVÉE. 

(incendie, inhalation, dommages aux surfaces du véhicule)

PRÉVENTION

RISQUE

DANGER

Summary of Contents for 919.724320

Page 1: ...OR Safety Guidelines Assembly Operation Maintenance Service and Adjustments Troubleshooting Repair Parts Model No 919 724320 CAUTION Read the Safety Guidelines and All Instructions Carefully Before Operating Sold by Sears Canada Inc Toronto Ont M5B 2B8 D24544 Rev 2 8 19 02 ...

Page 2: ... warranty will apply for ninety days 90 from the date of purchase This Craftsman Air Compressor warranty gives you specific legal rights and you may have other rights which vary from province to province Sears Canada Inc Toronto Ont M5B 2B8 TABLE OF CONTENTS WARRANTY 2 SPECIFICATION CHART 3 SAFETY GUIDELINES 3 8 GLOSSARY 9 ACCESSORIES 9 DUTY CYCLE 10 ASSEMBLY 10 INSTALLATION 11 12 OPERATION 13 15 ...

Page 3: ... this information we use the symbols below Please read the manual and pay attention to these sections IMPORTANT SAFETY INSTRUCTIONS Some dust created by power sanding sawing grinding drilling and other con struction activities contains chemicals known to the State of California to cause cancer birth defects or other reproductive harm Some example of these chemicals are lead from lead based paints ...

Page 4: ...LEAN DRY WELL VENTILATED AREA DO NOT OPERATE UNIT INDOORS OR IN ANY CONFINED AREA ALWAYS REMAIN IN ATTENDANCE WITH THE PRODUCT WHEN IT IS OPERATING ALWAYS DISCONNECT ELECTRICAL POWER BY MOVING PRESSURE SWITCH LEVER TO THE OFF POSITION AND DRAIN TANK DAILY OR AFTER EACH USE HOW TO PREVENT IT IT IS NORMAL FOR ELECTRICAL CONTACTS WITHIN THE MOTOR AND PRESSURE SWITCH TO SPARK IF ELECTRICAL SPARKS FROM...

Page 5: ...BASKETBALLS ETC 1 FAILURE TO PROPERLY DRAIN CON DENSED WATER FROM THE TANK CAUSING RUST AND THINNING OF THE STEEL TANK 2 MODIFICATIONS OR ATTEMPTED REPAIRS TO THE TANK 3 UNAUTHORIZED MODIFICATIONS TO THE UNLOADER VALVE SAFETY VALVE OR ANY OTHER COMPONENTS WHICH CONTROL TANK PRESSURE 4 EXCESSIVE VIBRATION CAN WEAKEN THE AIR TANK AND CAUSE RUPTURE OR EXPLOSION ATTACHMENTS ACCESSORIES EXCEEDING THE P...

Page 6: ...S CAN CAUSE SERIOUS INJURY OR DEATH SPRAYED MATERIALS SUCH AS PAINT PAINT SOLVENTS PAINT REMOVER INSECTICIDES WEED KILLERS MAY CONTAIN HARMFUL VAPORS AND POISONS RISK OF ELECTRICAL SHOCK HOW TO PREVENT IT WHAT CAN HAPPEN YOUR AIR COMPRESSOR IS POWERED BY ELECTRICITY LIKE ANY OTHER ELECTRICAL LY POWERED DEVICE IF IT IS NOT USED PROPERLY IT MAY CAUSE ELECTRIC SHOCK REPAIRS ATTEMPTED BY UNQUALIFIED P...

Page 7: ...D BY AUTHORIZED SERVICE CENTER PERSONNEL MOVING PARTS SUCH AS THE PULLEY FLY WHEEL AND BELT CAN CAUSE SERIOUS INJURY IF THEY COME INTO CONTACT WITH YOU OR YOUR CLOTHING ATTEMPTING TO OPERATE COMPRESSOR WITH DAMAGED OR MISSING PARTS OR ATTEMPTING TO REPAIR COMPRESSOR WITH PROTECTIVE SHROUDS REMOVED CAN EXPOSE YOU TO MOVING PARTS AND CAN RESULT IN SERIOUS INJURY HOW TO PREVENT IT WHAT CAN HAPPEN RIS...

Page 8: ... OF OPERATION WITH A FIRE EXTINGUISHER DO NOT OPERATE MACHINE WITH MISSING BROKEN OR UNAUTHORIZED PARTS UNSAFE OPERATION OF YOUR AIR COM PRESSOR COULD LEAD TO SERIOUS INJURY OR DEATH TO YOU OR OTHERS HOW TO PREVENT IT WHAT CAN HAPPEN RISK OF PROPERTY DAMAGE WHEN TRANSPORTING COMPRESSOR OIL CAN LEAK OR SPILL AND COULD RESULT IN FIRE OR BREATHING HAZARD SERIOUS INJURY OR DEATH CAN RESULT OIL LEAKS W...

Page 9: ... Straight Line Sander GLOSSARY Become familiar with these terms before operating the unit CFM Cubic feet per minute SCFM Standard cubic feet per minute a unit of measure of air deliv ery PSIG Pounds per square inch gauge a unit of measure of pressure Code Certification Products that bear one or more of the following marks UL CUL ETL CETL have been evaluated by OSHA certified independent safety lab...

Page 10: ...ed for Assembly 1 9 16 socket or open end wrench 1 1 2 socket or open end wrench Unpacking 1 Remove all packaging leaving the air compressor on the pallet 2 Remove and discard the 4 screws holding the air compres sor to the pallet It may be neces sary to brace or support one side of the air com pressor when removing the pallet because the air compressor will have a tendency to tip 3 Carefully remo...

Page 11: ...ng wire with an appropriate grounding plug see following illustra tions The plug must be used with an outlet that has been installed and grounded in accordance with all local codes and ordinances 1 The cord set and plug with this unit contains a grounding pin This plug MUST be used with a grounded outlet IMPORTANT The outlet being used must be installed and grounded in accordance with all local co...

Page 12: ...nd minimum branch circuit requirements Certain air compressors can be oper ated on a 15 amp circuit if the follow ing conditions are met 1 Voltage supply through branch circuit is 15 amps 2 Circuit is not used to supply any other electrical needs lights appliances etc 3 Extension cords comply with specifications 4 Circuit is equipped with a 15 amp circuit breaker or 15 amp time delay fuse NOTE If ...

Page 13: ... each use Pressure Switch The pressure switch automatically starts the motor when the air tank pressure drops below the factory set cut in pres sure It stops the motor when the air tank pressure reaches the factory set cut out pressure Safety Valve If the pressure switch does not shut off the air compressor at its cut out pressure setting the safety valve will protect against high pressure by popp...

Page 14: ...motor to restart freely When the motor stops running air will be heard escaping from this valve for a few seconds No air should be heard leaking when the motor is running or continuous leaking after unit reaches cut out pressure 14 ENG D24544 Check Valve Pressure Release Valve Before Starting Break in instructions Serious damage may result if the following break in instructions are not closely fol...

Page 15: ...or knob out turn counter clockwise until it stops Push knob in to lock in place 3 Attach hose and accessories NOTE The hose or accessory will require a quick connect plug if the air outlet is equipped with a quick connect 4 Move the On Auto Off lever to ON AUTO position The com pressor will start 5 Run the compressor for 15 min utes Make sure the drain valve is open and there is minimal air pressu...

Page 16: ...ming maintenance you may be exposed to voltage sources compressed air or moving parts Personal injuries can occur Before perform ing any maintenance or repair dis connect power source from the compressor and bleed off all air pressure To Check Safety Valve If the safety valve does not work properly over pressurization may occur causing air tank rupture or an explosion 1 Before starting compressor ...

Page 17: ...removed Motor The motor has an automatic reset thermal overload protector If the motor overheats for any reason the overload protector will shut off the motor The motor must be allowed to cool down before restarting The compressor will automatically restart after the motor cools If the overload protector shuts the motor off frequently check for a pos sible voltage problem Low voltage can also be s...

Page 18: ...nut 12 Replace the shroud and air filter 13 Perform the Break in Procedure See Break in Procedure in the Operation section Unit cycles auto matically when power is on When doing Maintenance you may be exposed to voltage sources compressed air or moving parts Personal injuries can occur Before performing any Maintenance or repair unplug the compressor and bleed off all air pressure ALL MAINTENANCE ...

Page 19: ...e and quick connect Orient outlet pressure gauge to read correctly Tighten quick connect with wrench To Replace Regulator 1 Release all air pressure from air tank See To Drain Tank in the Maintenance section 2 Unplug outfit 3 Remove the outlet pressure gauge and quick connect if equipped from the regulator 4 Remove the regulator 5 Apply pipe sealant tape to the nipple Nipple Outlet Pressure Gauge ...

Page 20: ...proximately 20 psi Release safety valve ring 6 Drain water from air tank by opening drain valve on bottom of tank Water will con dense in the air tank If not drained water will cor rode and weaken the air tank caus ing a risk of air tank rupture 7 After the water has been drained close the drain or drain valve NOTE If drain valve is plugged release all air pressure The valve can then be removed cl...

Page 21: ...n fittings where air can be heard escaping Check fittings with soapy water solution Do Not Overtighten Air leaks at fit tings Air leaks at pressure switch release valve Defective pressure switch release valve Contact a Trained Service Technician Air leaks in air tank or at air tank welds Defective air tank Air tank must be replaced Do not repair the leak Do not drill into weld or otherwise modify ...

Page 22: ...ressor is not supplying enough air to operate acces sories Prolonged excessive use of air Compressor is not large enough for air requirement Hole in hose Check valve restricted Air leaks Restricted air intake filter Decrease amount of air usage Check the accessory air requirement If it is higher than the SCFM or pressure supplied by your air com pressor you need a larger compressor Check and repla...

Page 23: ...witch will automatically reset Tank pressure exceeds pres sure switch cut in pres sure Motor will start automatically when tank pressure drops below cut in pressure of pressure switch Extension cord is wrong length or gauge Check for proper gauge wire and cord length Loose electrical connections Check wiring connection inside pressure switch and terminal box area Have checked by a Trained Service ...

Page 24: ...ent à compter de la date d achat sur un compresseur qui est utilisé à des fins com merciales ou comme appareil de location Cette garantie sur le compresseur d air de Craftsman vous donne des droits partic uliers Il se peut que vous ayez d autres droits qui varient d une province à l autre Sears Canada Inc Toronto Ont M5B 2B8 TABLE DES MATIÈRES GARANTIE 28 TABLEAU DES SPÉCIFICATIONS 29 MESURES DE S...

Page 25: ...duire l exposition à ces produits chimiques travaillez dans un endroit bien aéré et utilisez de l équipement de sécurité approuvé portez toujours un masque facial ou respirateur homologué MSHA NIOSH bien ajusté lorsque vous utilisez de tels outils Lorsque vous utilisez un outil pneumatique il faut toujours suivre les mesures de sécurité de base afin de réduire le risque de blessures corporelles ME...

Page 26: ... AÉRÉ LOIN DE TOUTE MATIÈRE COMBUSTIBLE ET DES VAPEURS D ESSENCE OU DE SOLVANTS SI DES MATIÈRES INFLAMMABLES DOIVENT ÊTRE VAPORISÉES SITUER LE COM PRESSEUR À UNE DISTANCE D AU MOINS 20 PIEDS DE LA ZONE DE VAPORISATION IL PEUT S AVÉRER NÉCESSAIRE D UTILISER UN BOYAU SUPPLÉMENTAIRE ENTREPOSER LES MATIÈRES INFLAMMA BLES DANS UN ENDROIT SÉCURITAIRE LOIN DU COMPRESSEUR NE JAMAIS PLACER DES OBJETS CONTR...

Page 27: ...E CAUSER DES DOMMAGES À LA PROPRIÉTÉ OU DES BLESSURES PORTER TOUJOURS DES LUNETTES DE PROTECTION HOMOLOGUÉES ANSI Z87 1 AVEC DES ÉCRANS LATÉRAUX LORS DE L U TILISATION DU COMPRESSEUR NE JAMAIS DIRIGER LA BUSE OU LE VAPOR ISATEUR VERS SOI VERS D AUTRES PER SONNES OU VERS DES ANIMAUX TOUJOURS METTRE LE COMPRESSEUR HORS FONCTION ET PURGER LA PRESSION DU BOYAU D AIR ET DU RÉSERVOIR AVANT D ENTAMER L E...

Page 28: ...DE MISE À LA TERRE PRÉVENTION RISQUE PRÉVENTION RISQUE L AIR OBTENU DIRECTEMENT DU COM PRESSEUR NE DEVRAIT JAMAIS ÊTRE UTILISÉ COMME SOURCE D AIR POUR LES ÊTRE HUMAINES SI L AIR PRODUIT PAR CE COMPRESSEUR SERA UTILISÉ POUR LA RES PIRATION IL FAUT INSTALLER DES FILTRES APPROPRIÉS AINSI QUE DU MATÉRIEL DE SÉCURITÉ LES FILTRES EN LIGNE ET LE MATÉRIEL DE SÉCURITÉ UTILISÉS AVEC LE COMPRESSEUR DOIVENT Ê...

Page 29: ...VENTE AUTORISÉ LES PIÈCES MOBILES TELLES QUE LA POULIE LE VOLANT MOTEUR ET LA COUR ROIE PEUVENT ENTRAÎNER DES BLESSURES GRAVES SI ELLES ENTRENT EN CONTACT AVEC UNE PARTIE DU CORPS OU DES VÊTEMENTS EN TENTANT DE FAIRE FONCTIONNER LE COMPRESSEUR AVEC DES PIÈCES MAN QUANTES OU ENDOMMAGÉES OU DE RÉPARER LE COMPRESSEUR SANS LES GARDES DE PROTECTION ON S EXPOSE AUX PIÈCES MOBILES CE QUI PEUT ENTRAÎNER D...

Page 30: ...Z JAMAIS D ANNULER LES CARACTÉRISTIQUES DE SÉCURITÉ DE CE PRODUIT ASSUREZ VOUS QU UN EXTINCTEUR D IN CENDIE EST DISPONIBLE DANS L AIRE DE TRAVAIL N UTILISEZ PAS L APPAREIL AVEC DES PIÈCES BRISÉES MANQUANTES OU NON AUTORISÉES RISQUE DE DOMMAGES À LA PROPRIÉTÉ PENDANT LE TRANSPORT DU COMPRESSEUR DES FUITES OU DES DÉVERSEMENTS D HUILE PEUVENT SE PRODUIRE ET ENTRAÎNER DES RISQUES D INCENDIE OU DES PRO...

Page 31: ...a haute pression à laquelle le moteur s arrête s appelle la pression de rupture Circuit de dérivation Le circuit acheminant l électricité du tableau électrique vers la prise murale ACCESSOIRES Cet appareil peut alimenter les accessoires suivants Les accessoires figurent dans le Catalogue actuel des outils électriques et manuels et sont également disponibles des magasins Sears vendant nos gammes co...

Page 32: ...uatre 4 vis fix ant le compresseur d air à la palette Il s avérera peut être nécessaire de supporter un côté du compresseur d air lors du retrait de la palette parce que le compresseur d air aura tendance à bas culer 3 Enlevez soigneusement le com presseur d air de la palette Contenu de l emballage en carton 1 Compresseur d air 2 Roues 2 Boulons à épaulement 3 8 16 2 Écrous hexagonaux 3 8 16 2 Par...

Page 33: ...quatement mis à la terre Ce compresseur d air portatif est doté d un cordon muni d un fil de mise à la terre et d une fiche appropriée de mise à la terre voir l illus tration ci dessous La fiche doit être insérée dans une prise de courant installée et mise à la terre conformément à tous les codes et ordon nances électriques locaux 1 Le cordon fourni avec cet appareil com prend une fiche avec broch...

Page 34: ... minimums concernant la tension et le circuit de dérivation Certains modèles de compresseur d air peuvent fonctionner sur un circuit de 15 ampères si les conditions suivantes sont satisfaites 1 la tension d alimentation au circuit de dérivation est de 15 A 2 le circuit n est pas utilisé pour ali menter d autres dispositifs élec triques lumières appareils élec triques etc 3 les rallonges sont confo...

Page 35: ...ression dans le réservoir d air tombe à une valeur inférieure à la pression d amorçage réglée à l usine Il arrête le moteur lorsque la pression dans le réservoir d air atteint la pression de rupture réglée à l usine Soupape de sûreté Si le manostat n ar rête pas le compresseur d air lorsque la pression de rupture est atteinte la soupape de sûreté protège contre toute surpression en sautant à la va...

Page 36: ...t normal que ce ventilateur souffle une grande quantité d air à travers les trous d aération L expulsion d air indique que le système de refroidissement est en fonction Pompe du compresseur d air non illus trée La pompe comprime l air pour le forcer dans le réservoir d air L air n est pas disponible pour travailler avant que le compresseur n ait élevé la pression du réservoir d air au niveau requi...

Page 37: ... bouton pour le verrouiller Le com presseur d air est maintenant prêt pour l utilisation REMARQUE Utilisez toujours le com presseur d air dans une région bien aérée sans vapeurs d essence ni autres vapeurs combustibles Si le compresseur est util isé avec un vaporisateur NE PAS placer le compresseur près de la région de vapori sation Avant chaque mise en marche 1 Placez le levier On Auto Off à la p...

Page 38: ...e bouton du régulateur vers l extérieur et tournez le dans le sens des aiguilles d une montre pour régler la pression de sortie à zéro 3 Enlevez l outil pneumatique ou l ac cessoire 4 Tirez l anneau de la soupape de sûreté pour permettre à l air de purg er du réservoir jusqu à ce que la pression dans le réservoir se situe à environ 20 lb po2 Relâchez l anneau de la soupape de sûreté 5 Vidangez l e...

Page 39: ... est équipé d un dispositif de protection contre les surcharges ther miques avec rétablissement automatique Si le moteur surchauffe pour quelque rai son que ce soit le dispositif de protection contre les surcharges arrêtera le moteur Laissez refroidir le moteur Le com presseur redémarrera automatiquement une fois que le moteur est bien refroidi Si le dispositif de protection contre les surcharges ...

Page 40: ...les protecteurs 13 Effectuez la procédure de rodage Voir la partie intitulée Procédures de rodage de la section sur l utilisation ENTRETIEN ET RÉGLAGES Tube de sortie Soupape de retenue Écrou Écrou Tube de décharge de pression En position fermée le disque est visible En position ouverte rien n est visible Tournevis TOUS LES SERVICES D ENTRETIEN NE FIGURANT PAS ICI DOIVENT ÊTRE EXÉCUTÉS PAR UN TECH...

Page 41: ...rtie de façon à ce qu il indique la pression correcte Serrez le raccord à l aide d une clé Remplacement du régulateur 1 Déchargez tout l air pressurisé du réservoir d air Voir la partie intitulée Vidange du réservoir de la section sur l entretien 2 Débranchez le compresseur d air 3 À l aide d une clé réglable retirez du régulateur le manomètre de sortie et le raccord à connexion rapide si compris ...

Page 42: ...e sûreté 6 Vidangez l eau du réservoir d air en ouvrant le robinet de vidange situé en bas du réservoir L eau dans le réservoir d air peut condenser Si le réservoir n est pas vidangé l eau corrodera et affaiblira les parois du réservoir d air causant ainsi un risque d éclatement du réservoir 7 Une fois la vidange de l eau ter minée fermez le robinet de vidange REMARQUE Si le robinet de vidange est...

Page 43: ...on d eau savonneuse Ne Pas Trop Serrer Fuites d air aux rac cords Fuites d air à la soupape de décharge du manos tat Soupape de décharge défectueuse du manostat Contactez un technicien qualifié Fuites d air au réservoir d air ou aux soudures du réservoir Réservoir d air défectueux Le réservoir d air doit être remplacé Ne tentez pas de réparer les fuites Ne pas percer souder ni modifier autrement l...

Page 44: ...es Utilisation prolongée et excessive de l air Le compresseur n est pas assez gros pour la quantité d air requise Trou dans le boyau Soupape de retenue obstruée Fuites d air Filtre d admission d air obstrué Diminuez la quantité d air utilisé Vérifiez les exigences en air de l ac cessoire Si elles sont plus élevées que la valeur SCFM pi3 min ou la pression produite par le com presseur vous avez bes...

Page 45: ...nos tat Vérifiez la rallonge pour s assurer qu elle est de longueur et de calibre approprié Vérifiez les connexions de câblage dans le manostat et la boîte à bornes Retirez et nettoyez ou remplacez la soupape Faire vérifier par un technicien de service qualifié Faire vérifier par un technicien de service qualifié N utilisez pas le com presseur d air dans une région de vaporisation de peinture Voir...

Page 46: ...NOTES REMARQUE ...

Page 47: ...NOTES REMARQUE ...

Page 48: ...and appliances in your own home no matter who made it no matter who sold it For your nearest Sears Parts and Service location to bring in products like vacuums lawn equipment and electronics For Sears Parts Service to order the replacement parts accessories and owner s manuals that you need to do it yourself www sears ca To purchase or inquire about a Sears Maintenance Agreement call 1 800 361 666...

Reviews: