17 - ENG
TO REPLACE REGULATOR
1. Release all air pressure from air
tank. See
To Drain Tank
in the
Maintenance
section.
2. Unplug compressor.
3. Remove shrouds.
4. Remove the outlet pressure gauge
and quick connect from the
regulator.
Outlet
Pressure
Gauge
Regulator
Quick
Connect
5. Remove the regulator.
6. Reapply pipe sealant to outlet
pressure gauge and quick
connect.
7. Assemble quick connect to new
regulator and tighten.
Regulator
Arrow
Quick
Connect
Nipple
8. Apply pipe sealant tape to the
nipple.
9. Assemble the regulator.
NOTE:
Arrow indicates flow of air. Make
sure it is pointing in the direction
of air flow.
10. Use the hex on quick connect
to tightening regulator. Orient as
shown.
11. Assemble outlet pressure gauge.
Orient outlet pressure gauge to
read correctly.
12. Replace shrouds.
STORAGE
Before you store the air compressor,
make sure you do the following:
1. Review the
Maintenance
section
on the preceding pages and per-
form scheduled maintenance as
necessary.
2. Drain water from air tank. See
To
Drain Tank
under
Maintenance
.
Water will
condense in the
air tank. If not drained, water will
corrode and weaken the air tank
causing a risk of air tank rupture.
3. Protect the electrical cord and
air hose from damage (such as
being stepped on or run over).
Wind them loosely around the
compressor handle.
4. Store the air compressor in a
clean and dry location.