background image

Summary of Contents for 919.167360 Operators

Page 1: ...Guidelines Assembly Operation Maintenance Service and Adjustments Troubleshooting Espahol CAUTION Read the Safety Guidelines and All Instructions Carefully Before Operating Sears Roebuck and Co Hoffman Estates IL 60179 U S A Visit our Craftsman website www sears com craftsman D23343 Rev 1 7 30 01 ...

Page 2: ... 13 To Replace or Clean Check Valve 13 To Replace Regulator 13 STORAGE 14 TROUBLESHOOTING GUIDE 15 17 ESPAI_IOL 18 33 HOW TO ORDER REPAIR PARTS Back Cover FULL ONE YEAR WARRANTY AIR COMPRESSOR If this air compressor fails due to a defect in material or workmanship within one year from the date of purchase RETURN IT TO THE NEAREST SEARS REPAIR CENTER THROUGHOUT THE UNITED STATES AND SEARS WILL REPA...

Page 3: ...ACTS WITHIN THE MOTOR AND PRESSURE SWITCH TO SPARK IF ELECTRICAL SPARKS FROM COMPRESSOR COME INTO CONTACT WITH FLAMMABLE VAPORS THEY MAY IGNITE CAUSING FIRE OR EXPLOSION RESTRICTING ANY OF THE COMPRESSOR VENTILA TION OPENINGS WILL CAUSE SERIOUS OVERHEATING AND COULD CAUSE FIRE UNATTENDED OPERATION OF THIS PRODUCT COULD RESULT IN PERSONAL INJURY OR PROPERTY DAM AGE HOW TO PREVENT IT ALWAYS OPERATE ...

Page 4: ...E TANK OR ITS ATTACHMENTS THE TANK IS DESIGNED TO WITHSTAND SPECIFIC OPER ATING PRESSURES NEVER MAKE ADJUSTMENTS OR PARTS SUBSTITUTIONS TO ALTER THE FACTORY SET OPERATING PRESSURES FOR ESSENTIAL CONTROL OF AIR PRESSURE YOU MUST INSTALL A PRESSURE REGULATOR AND PRES SURE GAUGE TO THE AIR OUTLET IF NOT EQUIPPED OF YOUR COMPRESSOR FOLLOW THE EQUIPMENT MANUFACTURERS RECOMMENDATION AND NEVER EXCEED THE...

Page 5: ... AGE AND ADEQUATE FUSE PROTECTION RISK TO BREATHING WHAT CAN HAPPEN THE COMPRESSED AIR DIRECTLY FROM YOUR COM PRESSOR IS NOT SAFE FOR BREATHING THE AIR STREAM MAY CONTAIN CARBON MONOXIDE TOXIC VAPORS OR SOLID PARTICLES FROM THE TANK BREATHING THESE CONTAMINANTS CAN CAUSE SERIOUS INJURY OR DEATH SPRAYED MATERIALS SUCH AS PAINT PAINT SOL VENTS PAINT REMOVER INSECTICIDES WEED KILLERS CONTAIN HARMFUL ...

Page 6: ...AIRS REQUIRED ON THIS PRODUCT SHOULD BE PERFORMED BY AUTHORIZED SERVICE CENTER PERSONNEL RISK OF FALLING WHAT CAN HAPPEN HOW TO PREVENT IT A PORTABLE COMPRESSOR CAN FALL FROM A TABLE ALWAYS OPERATE COMPRESSOR IN A STABLE WORKBENCH OR ROOF CAUSING DAMAGE TO THE SECURE POSITION TO PREVENT ACCIDENTAL MOVE COMPRESSOR AND COULD RESULT IN SERIOUS MENT OF THE UNIT NEVER OPERATE COMPRESSOR INJURY OR DEATH...

Page 7: ...nch Circuit Circuit carrying electricity from elec trical panel to outlet This unit is capable of powering the following Accessories The accessories are available through the current Power and Hand Tool Catalog or full line Sears stores Accessories In Line Filter Tire Air Chuck Quick Connector Sets various sizes Air Pressure Regulators Oil Fog Lubricators Air Hose 1 4 5 16 OR 3 8 I D in various le...

Page 8: ... completely understood or if in doubt as to whether the com pressor is properly grounded have the installation checked by a qualified electrician IMPROPER GROUNDING IN ELEC TRICAL SHOCK Do not modify the plug provided If it does not fit the available outlet a correct outlet should be installed by a qualified electri cian Repairs to the cord set or plug MUST be made by a qualified electrician Exten...

Page 9: ...clockwise to increase pressure and counterclockwise to decrease pressure When the desired pressure is reached push knob in to lock in place Regulator Drain Valve The drain valve is located at the base of the air tank and is used to drain condensa tion at the end of each Valve use Cooling System not shown This compressor con tains an advanced design cooling system At the heart of this cooling syste...

Page 10: ...ob out turn counter clockwise until it stops Push knob in to lock in place Attach hose and accessories NOTE The hose or accessory will require a quick connect plug if the air outlet is equipped with a quick connect Too much air pressure causes a hazardous risk of bursting Check the manufacturer s maximum pressure rating for air tools and accessories The regulator outlet pressure must never exceed ...

Page 11: ...tes freely If the valve is stuck or does not operate smoothly it must be replaced with the same type of valve To Drain Tank 1 Set the On Auto Off lever to OFF 2 3 4 5 Pull the regulator knob out and turn clockwise to set the outlet pressure to zero Remove the air tool or accessory Pull ring on safety valve allowing air to bleed from the tank until tank pressure is approximately 20 psi Release safe...

Page 12: ...es Motor The motor has an automatic reset thermal overload protector if the motor overheats for any reason the overload protector will shut off the motor The motor must be allowed to cool down before restarting The compressor will automatically restart after the motor cools if the overload protector shuts the motor off frequent ly check for a possible voltage problem Low voltage can also be suspec...

Page 13: ... To Drain Tank in the Maintenance section 2 Unplug outfit 3 Remove the outlet pressure gauge and quick connect if equipped from the regulator 4 Remove the regulator Outlet Tube Regulator 4 Using an adjustable wrench loosen pressure relief tube nut at air tank and pressure switch Carefully move pressure relief tube away from check valve 5 Unscrew the check valve turn counterclockwise using a 7 8 op...

Page 14: ... Release safety valve ring 6 Drain water from air tank by opening drain valve on bottom of tank 7 Water will condense in the air tank If not drained water will corrode and weaken the air tank causing a risk of air tank rupture After the water has been drained close the drain or drain valve NOTE if drain valve is plugged release all air pres sure The valve can then be removed cleaned then reinstall...

Page 15: ...nt air leak at the pressure release valve when there is pres sure in the tank and the compres sor is shut off Replace check valve Refer the To Replace or Clean Check Valve in the Service and Adjustment section Air leaks at pressure switch Defective pressure switch release Contact a Trained Service release valve valve Technician Air leaks in air tank or at air tank Defective air tank Air tank must ...

Page 16: ...longed excessive use of air Compressor is not large enough for air requirement Hole in hose Check valve restricted Air leaks Restricted air intake filter Damaged regulator Damaged regulator Check the accessory air require ment If it is higher than the SCFM or pressure supplied by your air compressor you need a larger compressor Check and replace if required Remove and clean or replace Tighten fitt...

Page 17: ...gth Remove and clean or replace Check wiring connection inside pressure switch and terminal box area Have checked by a Trained Service Technician Have checked by a Trained Service Technician Do not oper ate the compressor in the paint spray area See flammable vapor warning Bleed the line by pushing the lever on the pressure switch to the off position if the valve does not open replace switch 1 Che...

Page 18: ...ssor de aire 28 Motor 28 SERVIClO Y AJUSTES 29 Para reemnplazar o limpiar la vAIvula reguladoa 29 Para reemplazar el regulador 29 ALMAOENAJE 30 GU A DE DIAGNOSTICO DE PROBLEMAS 31 33 COMO SOLIClTAR PIEZAS PARA REPARAClON contratapa GARANTIA COMPLETA POR UN AI_IO COMPRESOR DE AIRE Si este compresor de aire fallara por defectos en materiales o mano de obra dentro del lapso de un aSo a partir de la f...

Page 19: ...RUPTOR A PRESION SI LAS CHISPAS ELECTRICAS PROVENIENTES DEL COMPRESOR TOMARAN CONTACTO CON EMANAClONES DE MATERIALES INFLAMABLES ELLOS PODRIAN ARDER ORIGINANDO INCENDIO O EXPLOSION RESTRINGIR CUALQUIERA DE LAB ABERTURAS DE VENTILAClON CAUSARA UN SERIO RECALENTAMIENTO Y PODRJA PRODUCIR UN INCENDIO DE JAR DESATENDIDO ESTE PRODUCTO MIENTRAS EL MISMO EST _ EN FUNCIONAMIENTO PUEDE RESULTAR EN LESIONES ...

Page 20: ... TANQUE O SUS ACCESORIOS EL TANQUE EST _ DISEi_ADO PARA RESISTIR PRESIONES OPERATIVAS ESPECJFICAS JAMAS EFECTUE AJUSTES O SUSTITUYA PARTES QUE ALTEREN LAS REGULAClONES DE PRESION ORIGINALES DE Fh BRICA PARA UN CONTROL ESENCIAL DE LA PRESION DEBE USTED INSTALAR UN REGULADOR Y UN MEDIDOR DE PRESION A LA SALIDA DEL AIRE DE SU COMPRESOR SI NO ESTUNIER EQUIPADO SIGA LAS RECOMENDACIONES DE LOS FABRICANT...

Page 21: ... DE FUSlBLES RIESGO DE INHALAClON QU I_ PUEDE OCURRIR COMO PREVENIRLO EL AIRE COMPRIMIDO PROVENIENTE DEL COMPRESOR NO ES SANO PARA RESPIRAR EL CHORRO DE AIRE PUEDE CONTENER MONOXlDO DE CARBONO VAPORES T DXlCOS O PARTICULAS SOLIDAS PROVENIENTES DEL TANQUE LA INHALAClON DE DICHOS CONTAMINANTES PUEDE LLEGAR A CAUSAR SERIAS LESlONES O LA MUERTE EL ROCIADO DE MATERIALES TALES COMO PINTURA SOLVENTES REM...

Page 22: ...IDA POR ESTE PRODUCTO DEBE SER EFECTUADA POR PERSONAL AUTORIZADO DE LOS SERVlCENTROS RIESGO DE CAIDA _ QUE PUEDE OCURRIR COMO PREVENIRLO UN COMPRESOR PORTATIL PUEDE CAERSE DE LA MESA EL OPERE SIEMPRE EL COMPRESOR EN UNA POSICION BANCO DE TRABAJO O DEL TECHO DAI_IANDO AL COMPRESOR Y ESTABLE Y SEGURA A FIN DE PREVENIR EL MOVIMIENTO PUDIENDO RESULTAR EN SERIAS LESlONES O LA MUERTE ACCIDENTAL DE LA UN...

Page 23: ...ibles a trav6s del cat_ logo para herramientas el6ctricas y manuales en cualquiera de los comercios que mantiene la linea completa de SEARS Accesorios Filtro en linea Entrada de aire a neumAtieos Juegos de conectores rapidos varies tamaSos Reguladores de presi6n de aire Lubricadores de niebla de aceite Manguera de aire 1 4 3 8 o 1 2 D L en varias medidas Herramientas especiales Pistola de inflado ...

Page 24: ...haga verificar la instalaci6n por un elec tricista competente LA CONEXION INADECUADA A TIERRA PUEDE DETERMINAR UNA DESCARGA ELleCTRICA No modifique el enchufe provisto Si el mismo no penetrara el tomacorriente disponible un eleetricista competente debera instalar uno apropiado La reparaci6n del cable o del enchufe DEBERA ser efectuada por un eleetricista competente Cables de extensi6n el_ctrica Us...

Page 25: ...agalo en sentido inverso para disminuirla Cuando se Iogre la presibn desea da presione la perilla para bloquearla Valvula de drenaje La v_ lvula de drenaje se encuen tra ubicada sobre la base del tanque de aire y se usa para Valvula de drenar la condensaci6n al fin drenaj_ de cada uso Sistema de enfriamiento no mostrado Este eompresor contiene un sietema de avanzada para el control de enfri amient...

Page 26: ...imite Empuje la perilla haste su posici6n blocante 3 Conecte la manguera y accesorios NOTA Tanto la manguera como los accesorios requerirAn un enchufe de conexi6n rapi da si la salida del aire esta equipada con un z6calo de conex i6n rapid Demasiada presi6n de aire podra ser la causa de riesgo de explosi6n Verifique los valores de maxima presi6n dados por el fabricante de las herramientas neumAtic...

Page 27: ...e si la valvula quedase trabada o no trabajara c6modamente debera set reemplazada pot el mismo tipo de vAIvula Cbmo drenar el tanque 1 Coloque la palanca On Auto Off en la posici6n OFF 2 Tire de la perilla del regulador y gire en sentido horario para establecer la salida de presi6n en cero 3 Remueva la herramienta neum tica o el accesorio 4 Tire del are de la v_ lvula de seguridad dejando purgar e...

Page 28: ...Motor El motor tiene un protector de sobrecarga t_rmico de reposici6n automatica Si el motor se sobrecalienta por alguna raz6n el protector de sobrecarga apagardt el motor Debe dejar enfriar el motor antes de volverlo a arrancar El compresor arrancar autom ticamente despu6s que se enfrie el motor Si el protector de sobrecarga apaga el motor con mucha frecuencia verifique si hay algQn posible probl...

Page 29: ... Desenchufe el equipo 3 Usando una Ilave de tuereas ajustable retire el medider de salida de presi6n y la conexi6N rapids del regulader si la tiene 4 Extraiga el regulador 4 Utilizando una Ilave regulable afloje el tube aliviador de presi6n del tanque de aire y el interruptor de presi6n Retire cuidadosamente la tuberia de alivio de presi6n de la v_lvula de retenci6n 5 Desenrosque la v_ lvula de re...

Page 30: ...alvula de seguridad 6 Drene el agua del tanque de aire abriendo la vAIvula de drenaje ubicada en el fondo del tanque 7 El agua se conden sa dentro del tanque de aire Si no se drena ella corroerA debilitando la paredes del tanque de aire originando un riesgo de ruptura de sus pare des Una vez que el agua haya sido drenada cierre la vAIvula de drenaje NOTA Si la valvula de drenaje estuviese enchufad...

Page 31: ...a una fuga constante de aire en la v lvula de alivio de presi6n cuando hay presi6n en el tanque y se apaga el compresor Reemplace la v lvula de retenci6n Consulte C6mo Reemplazar o Limpiar la V lvula de Retenci6n en la secci6n Operaci6n P dida de presi6n de aire en el Un interruptor de presi6n defectuoso Contacte a un t6cnico calificado en interruptor de la valvula aliviadora libera la valvula ser...

Page 32: ...da del aire El compresor no tiene suficiente capacidad para el requerimiento de aire al que esta sometido Orificio en la manguera V lvula reguladora restringida P6rdida de aire Filtro de entrada de aire restringido Regulador daSado Regulador daSado Verifique los requerimientos de aire del accesorio Si fuera mas elevado que SCFM o la presi6n suministrada por su compresor usted necesita un compresor...

Page 33: ...el cord6n Retire y limpie o reemplace Compruebe la conexi6n de cableado dentro del interruptor de presi6n y del area de la caja de terminales Haga inspeccionar pot un tecnico eapacitado de servicio Haga inspeccionar por un t6cnico capacitado de servicio No haga funcionar el compresor en el area de pintura por rociado Yea la advertencia acerca de vapores inflamables Purgue la linea empujando la pal...

Page 34: ...D23343 34 SP ...

Page 35: ...35 SP D23343 ...

Page 36: ...nd owner s manuals that ou dt_odo i ou se ca ears ar O 1 800 366 PART 6a m 11p m CaT 1 800 366 7278 7 days a week www sears com partsdirect To purchase or inquire about tSears Service Agreement 1 800 827 6655 7 a m 5 p m CST Mon Sat Pard pedir servicio de reparaci6n a domioilio Au Canada pour service en frangais y pard ordenar piezas con entrega a domicilio 1 877 LE FOYER sM 1 888 SU HOGAR sM 1 87...

Reviews: