31
OPERATION
Your garage door opener is equipped with features to provide you
with greater control over your garage door operation.
TIMER-TO-CLOSE
The Timer-to-Close feature automatically closes the door after a
specified time period that can be adjusted using the door control.
Prior to the door closing there will be an audible and visual alert.
ASSURELINK™
AssureLink™ technology uses a 900MHz signal to provide
two-way communication between the garage door opener and
AssureLink™ accessories. Your garage door opener is compatible
with up to 8 AssureLink™ accessories.
ASSURELINK™ REMOTE CONTROLS AND DOOR CONTROLS
Your garage door opener has already been programmed at the
factory to operate with your remote control, which changes with
each use, randomly accessing over 100 billion new codes. Older
Craftsman accessories are not compatible.
IMPORTANT SAFETY INSTRUCTIONS
To reduce the risk of SEVERE INJURY or DEATH:
WARNING
1. READ AND FOLLOW ALL WARNINGS AND INSTRUCTIONS.
2. ALWAYS keep remote controls out of reach of children.
NEVER permit children to operate or play with garage door
control push buttons or remote controls.
3. ONLY activate garage door when it can be seen clearly, it is
properly adjusted, and there are no obstructions to door
travel.
4. ALWAYS keep garage door in sight and away from people
and objects until completely closed. NO ONE SHOULD
CROSS THE PATH OF THE MOVING DOOR.
5. NO ONE SHOULD GO UNDER A STOPPED, PARTIALLY
OPENED DOOR.
6. If possible, use emergency release handle to disengage
trolley ONLY when garage door is CLOSED. Use caution
when using the release with the door open. Weak or broken
springs or unbalanced door could result in an open door
falling rapidly and/or unexpectedly, and increasing the risk of
SEVERE INJURY or DEATH.
7. NEVER use emergency release handle unless garage
doorway is clear of persons and obstructions.
8. NEVER use handle to pull garage door open or closed. If
rope knot becomes untied, you could fall.
9. After ANY adjustments are made, the safety reversal
system MUST be tested.
10. Safety reversal system MUST be tested every month.
Garage door MUST reverse on contact with 1-1/2" high
(3.8 cm) object (or a 2x4 laid flat) on the floor. Failure to
adjust the opener properly increases the risk of SEVERE
INJURY or DEATH.
11. ALWAYS KEEP GARAGE DOOR PROPERLY BALANCED
(see page 3). An improperly balanced door may NOT
reverse when required and could result in SEVERE INJURY
or DEATH.
12. ALL repairs to cables, spring assemblies and other
hardware, ALL of which are under EXTREME tension,
MUST be made by a trained door systems technician.
13. ALWAYS disconnect electric power to garage door opener
BEFORE making ANY repairs or removing covers.
14. This operator system is equipped with an unattended
operation feature. The door could move unexpectedly. NO
ONE SHOULD CROSS THE PATH OF THE MOVING DOOR.
15. DO NOT enable the Timer-to-Close functionality if operating
either one-piece or swinging garage doors. To be enabled
ONLY when operating a sectional door.
16.
SAVE THESE INSTRUCTIONS.
THE PROTECTOR SYSTEM
®
(SAFETY REVERSING SENSORS)
When properly connected and aligned, the safety reversing
sensors will detect an obstruction in the path of the infrared
beam. If an obstruction breaks the infrared beam while the door
is closing, the door will stop and reverse to full open position,
and the opener lights will flash 10 times. If the door is fully open,
and the safety reversing sensors are not installed, or are
misaligned, the door will not close from a remote control.
However, you can close the door if you hold the button on the
door control or keyless entry until the door is fully closed. The
safety reversing sensors do no effect the opening cycle.
ENERGY CONSERVATION
For energy efficiency the garage door opener will enter sleep
mode when the door is fully closed. The sleep mode shuts the
garage door opener down until activated. The sleep mode is
sequenced with the garage door opener light bulb; as the light
bulb turns off the sensor LEDs will turn off and whenever the
garage door opener lights turn on the sensor LEDs will light.
The garage door opener will not go into the sleep mode until the
garage door opener has completed 5 cycles upon power up.
LIGHTS
The garage door opener light bulbs will turn on when the opener
is initially plugged in; power is restored after interruption, or
when the garage door opener is activated. The lights will turn off
automatically after 4-1/2 minutes. An incandescent A19 light bulb
(100 watt maximum) or for maximum energy efficiency a 26W
(100W equivalent) compact fluorescent light (CFL) bulb may
be used.
Features
Accessories
MEMORY CAPACITY
Remote Controls
Up to 8
Door Controls
Up to 2 AssureLink™ door controls.
Keyless Entries
Up to 1
Summary of Contents for 139.30437
Page 41: ...41 NOTES ...
Page 79: ...39 NOTAS ...