background image

3. Installation Preparation.

4. Hanging Bracket Installation.

page 3

ON

OFF

ON

OFF

Turn off circuit breakers to current fixture from breaker 
panel and be sure operating light switch is turned to 
the OFF position.

WARNING: 

Failure to disconnect power supply prior to 

installation may result in serious injury.

Remove existing fixture. 

WARNING:

 When using an existing outlet box, be sure the 

outlet box is securely attached to the building structure 
and can support the full weight of the fan. Ensure outlet 
box is clearly marked "Suitable for Fan Support." If not, it 
must be replaced with an approved outlet box. Failure to 
do so can result in serious injury.

CAUTION:

 Be sure outlet box is properly grounded and 

that a ground (

GREEN

 or bare) wire is present.

Install hanging bracket to outlet box using original 
screws, spring washers and flat washers provided with 
new or original outlet box.

If installing on a vaulted 

ceiling, face opening of hanging bracket towards high 
point of ceiling. Arrange electrical wiring around the 
back of the hanging bracket.

*Note

: It is very important that you use the proper 

hardware when installing the hanging bracket as this will 
support the fan. 

Vaulted ceiling 
angle is not to 
exceed 25 degrees.  

downrod

installation

flushmount

installation

7 feet

(2.13 m) (76 cm)

30 

inches

12 ft. - 20 ft.

(3.66 m - 6.1 m)

(3.66 m - 6.1 m)  

blade edge

To prevent personal injury and damage, ensure 
that the hanging location allows the blades a 
clearance of 7 feet (2.13 m) from the floor and 
30 in (76 cm) from any wall or obstruction. 
This fan is suitable for room sizes up to 400 square 
feet (37.2 square meters).

Installation requires these tools:

Phillips screwdriver, flathead screwdriver, 
adjustable pliers or wrench, stepladder, wire 
cutters, and rated electrical tape.

This fan can be mounted with a 

downrod

on a regular (no-slope) or vaulted ceiling.  The 
hanging length can be extended by purchasing 
a longer downrod (0.5 in /1.27 cm diameter). 
Other installation, such as

 flushmount

, is 

not

 

available for this fan.

12 f

t.

 - 20 f

t.

hanging bracket

spring washers

outlet box screws

flat washers

Summary of Contents for YOR52

Page 1: ...nging Bracket Installation pg 3 Fan Assembly pgs 4 5 Wiring pg 6 Canopy Assembly pg 6 Blade Assembly pg 7 Switch Housing Assembly pgs 7 8 Testing Your Fan pg 8 Light Kit Assembly Optional pg 9 Trouble...

Page 2: ...12 gauge or there is more than one house wire to connect to the corresponding fan lead wires consult an electrician for the proper size wire connectors to use 5 Electrical diagrams are for reference...

Page 3: ...against parts inventory that all parts have been included 2 Parts Inventory IMPORTANT REMINDER You must use the parts provided with this fan for proper installation and safety a canopy 1 piece b hang...

Page 4: ...ging bracket towards high point of ceiling Arrange electrical wiring around the back of the hanging bracket Note It is very important that you use the proper hardware when installing the hanging brack...

Page 5: ...for pin and clip in downrod align with holes in yoke make sure wires do not get twisted Re insert pin and clip that were previously removed Tighten yoke set screws and nuts securely Refer to diagram...

Page 6: ...hanging bracket Turn the hanging ball slot until it lines up with the hanging bracket tab WARNING Failure to align slot in hanging ball with tab in hanging bracket may result in serious injury or dea...

Page 7: ...UE wire with a wire connector as shown with arrow in diagram Note If you elect to purchase a light kit for the fan the BLUE wire from the fan must be connected to the BLACK or RED wire from the ceilin...

Page 8: ...ews Note Tighten blade arm screws twice a year blade arm screws lock washers motor housing blade arm blade blade attachment screws and washers 9 Switch Housing Assembly Remove 4 screws from outer edge...

Page 9: ...ill set the fan to MEDIUM Third pull will set the fan to LOW Fourth pull will again set the fan to the OFF setting If fan does not function please refer to Troubleshooting section to solve any issues...

Page 10: ...tch housing Connect BLACK wire from light kit fitter to BLUE or BLACK wire from switch housing Be sure molex connections snap together securely Refer to diagram b Connect male plug from the motor hous...

Page 11: ...hipping of the product for repairs This warranty does not apply when damage from mechanical physical electrical or water abuse results in causing the malfunction Deterioration of finishes or other par...

Page 12: ...dor P gs 4 5 Instalaci n el ctrica P g 6 Colocaci n de la cubierta decorativa P g 6 Colocaci n de las aspas P g 7 Instalaci n de la caja de encendido P gs 7 8 Verificaci n del funcionamiento del venti...

Page 13: ...s superior al 12 o hay m s de un cable de la casa para conectar a los cables principales del ventilador al cual corresponda cada uno consultar con un electricista para informarse sobre el tama o corre...

Page 14: ...incluyeron todas 2 Inventario de piezas RECORDATORIO IMPORTANTE Se tienen que utilizar las piezas provistas con este ventilador para una instalaci n adecuada y su seguridad a cubierta decorativa 1 un...

Page 15: ...o Arreglar el alambrado el ctrico los cables en la parte de atr s del soporte y lejos de la abertura del soporte Nota Es muy importante usar los art culos de ferreter a correctos al instalar el soport...

Page 16: ...introducir el perno y la clavija que se quitaron anteriormente Apretar los tornillos de fijaci n del cuello y la tuerca completamente Referirse al diagrama 2 Deslizar la cubierta del cuello y la cubi...

Page 17: ...izar tornillo para madera para trabajos pesados arandela y arandela de seguridad no provistos para asegurar el bucle del cable de seguridad Si es necesario ajustar el bucle en el extremo del cable de...

Page 18: ...s cables de la casa el edificio son de colores diferentes a los cuales se refieren a continuaci n favor de buscar un electricista calificado Nota Si la longitud del alambrado que sale del ventilador e...

Page 19: ...petir el mismo procedimiento con los dem s brazos para las aspas Apretar bien todos los tornillos Nota Apretar los tornillos para los brazos para las aspas dos veces al a o placa de conexi n placa de...

Page 20: ...en marcha ALTA El segundo tir n controla el ventilador para que se baje a marcha MEDIA El tercer tir n bajar el ventilador a marcha BAJA Con el cuarto tir n se APAGAR el ventilador de nuevo Si el vent...

Page 21: ...la cubierta de la caja de encendido Conectar el cable NEGRO del conectador para el juego de luz al cable AZUL o NEGRO de la cubierta de la caja de encendido Asegurarse de que se conecten bien las con...

Page 22: ...ventilador tenga da os por abuso mec nico f sico el ctrico o por agua resultando en su mal funcionamiento Se exenta espec ficamente el deterioro en el acabado u otras partes debido al tiempo o exposi...

Reviews: