background image

7. Attachment of Motor Housing.

page 5

8. Blade Assembly.

6. Fan Assembly.

Carefully push wiring and wire nuts into 
outlet box.

Align 4 holes in bar at top of motor assembly 
with 4 holes in hanging bracket. Secure 
motor assembly to hanging bracket with 4 
motor mounting screws and lock washers  
that were previously removed (

page 3, 

Section 4

).

[

Note

: It is extremely important to 

tighten the 

screws so 

that fan can be mounted securely.] 

Raise motor housing to hanging bracket to 
align screws on internal top rim of motor 
housing with slotted holes on hanging 
bracket.  Twist motor housing to lock. 

Time Saver: 

Washers for blade screws can be set 

on each blade screw prior to installing blades. 

Locate 6 blade attachment screws in one of the 
hardware packs. Align blade holes with motor 
screw holes, 

turn blade so that the 3  small holes 

on each outer edge of blade are facing up towards 
the ceiling,

 and attach blade  with  blade  screws. 

[

Note

: Use slot located on switch housing plate 

for easy access to motor screw holes.] Before 
securing screws permanently, repeat with the 
other blade . Secure all screws with a Phillips 
screwdriver.

Note

: Tighten blade screws twice a year.

hanging 

bracket

motor assembly

motor housing

blade attachment
screws and washers

switch housing slot

blade

"bar"

hanging bracket

motor housing

slotted holes

screws

Summary of Contents for WarPlanes WB242

Page 1: ...t Kit Assembly Optional pg 6 Handheld Remote Control Assembly pg 7 Automated Learning Process Activating Code pg 8 Remote Control Operation pg 8 Testing Your Fan pg 8 Troubleshooting pg 9 Parts Replac...

Page 2: ...re than one house wire to connect to the corresponding fan lead wires consult an electrician for the proper size wire connectors to use 5 Electrical diagrams are for reference only Light kits that are...

Page 3: ...included 2 Parts Inventory a hanging bracket 1 piece b motor assembly 1 piece c motor housing 1 piece d metal cover 1 piece e light kit fitter 1 piece f wall control 2 pieces g plate 1 piece h remote...

Page 4: ...Failure to disconnect power supply prior to installation may result in serious injury Remove existing fixture WARNING When using an existing outlet box be sure the outlet box is securely attached to...

Page 5: ...DIM and ON OFF has been pre set to the ON position DIM If you do not wish to have dimming capability please move the switch to the OFF position ON OFF Select a faceplate almond or white and press firm...

Page 6: ...Twist motor housing to lock Time Saver Washers for blade screws can be set on each blade screw prior to installing blades Locate 6 blade attachment screws in one of the hardware packs Align blade hole...

Page 7: ...rapping bulb was packed with to layer around glass portion of bulb Locate slots on glass shade and align with nodules inside light kit fitter Gently push up on glass shade and turn to the RIGHT clockw...

Page 8: ...have dimming capability please move the switch to the OFF position ON OFF Refer to diagram 2 Attach black faceplate to front of wall control press down firmly Refer to diagram 3 Align holes in wall co...

Page 9: ...dheld remote control for 5 seconds or until light blinks twice Test the light and fan functions to confirm the learning process is complete see Section 13 below handheld remote control 1 1 2 2 It is r...

Page 10: ...r Craftmade Ellington nor the manufacturer will assume any liability resulting from improper installation or use of this product In no case shall the company be liable for any consequential damages fo...

Page 11: ...olocaci n del bastidor del motor P g 5 Colocaci n de las aspas P g 5 Instalaci n del juego de luz opcional P g 6 Ensamblaje del control remoto de mano P g 7 Proceso de aprendizaje autom tico El activa...

Page 12: ...al 12 o hay m s de un cable de la casa para conectar a los cables principales del ventilador al cual corresponda cada uno consultar con un electricista para informarse sobre el tama o correcto de cone...

Page 13: ...ezas a soporte de montaje 1 unidad b unidad del motor 1 unidad c bastidor del motor 1 unidad d cubierta de metal 1 unidad e conectador para el juego de luz 1 unidad f control de pared 2 unidades g pla...

Page 14: ...uerza antes de la instalaci n puede tener por resultado lesiones graves Quitar el aparato existente ADVERTENCIA Si utiliza una caja de salida existente asegurarse de que la caja de salida est firmemen...

Page 15: ...PORTANTE El control de pared no funcionar sin que se instale la bater a Ya que este ventilador viene con bombilla hal gena el interruptor del reductor de luz etiquetado DIM y ON OFF est programado de...

Page 16: ...ahorrar tiempo Se pueden poner las arandelas en los tornillos que son para las aspas antes de colocar las aspas Localizar 6 tornillos en uno de los paquetes de art culos de ferreter a Alinear los aguj...

Page 17: ...lla para manipular la parte de la bombilla hecha de vidrio Localizar las ranuras en la pantalla de vidrio y alinearlas con los n dulos en el conectador para el juego de luz Empujar la pantalla de vidr...

Page 18: ...l diagrama 3 Alinear los agujeros en el control de pared con los postes que se encuentran adentro de la parte SUPERIOR de la cubierta del control remoto y apretar fijamente Colocar el control de pared...

Page 19: ...iones de la secci n 11 m s arriba 1 1 2 2 12 Funcionamiento del control remoto Interruptor corredero ON OFF ENCIENDE y APAGA el control de pared el interruptor no funciona en el control de mano Bot n...

Page 20: ...s de art culos de ferreter a Si no se incluye un juego para balancear las aspas llamar al Servicio al cliente 1 800 486 4892 para pedir uno Para piezas o informaci n referirse al Inventario de piezas...

Reviews: