background image

page 5

5. Fan Assembly. (cont.)

With the hanging bracket secured to the outlet box and 
able to support the fan, you are now ready to hang your 
fan. Grab the fan firmly with two hands. Slide downrod 
through opening in hanging bracket and let hanging ball 
rest on the hanging bracket. Turn the hanging ball slot 
until it lines up with the hanging bracket tab.

WARNING

: Failure to align slot in hanging ball with tab in 

hanging bracket may result in serious injury or death.

Tip:

 Seek the help of another person to hold the 

stepladder in place and to help lift the fan up to you once 
you are set on the ladder. 

Find a secure attachment point (wood ceiling joist highly 
recommended) and secure safety cable. It will be 
necessary to use a heavy duty wood screw, washer and 
lock washer (not supplied) with the safety cable loop. If 
necessary, adjust the loop at the end of the safety cable. 
The loop at the end of the safety cable should just fit over 
the threads on the wood screw. 

Test safety cable by pulling 

on loose end with pliers. If the safety cable slips, the loop 
must be adjusted tighter.

 Extra cable slack can be left in 

ceiling area. 

motor housing

safety cable

hanging bracket tab

hanging ball slot

wood ceiling joist

wood screw

and washer

safety cable loop

6. Wiring.

WARNING

: Turn off circuit breakers to current fixture 

from breaker panel and be sure switch is turned to 
the OFF position.

CAUTION

Be sure outlet box is properly grounded and 

that a ground (

GREEN

 or Bare) wire is present.

Make sure all electrical connections comply with Local 
Codes or Ordinances and the National Electrical Code. If 
you are unfamiliar with electrical wiring or if the 
house/building wires are different colors than those 
referred to in the instructions, please use a qualified 
electrician.

Note

Excess lead wire length from the fan can be cut to 

the desired length and then stripped.

When downrod is secured in place on the hanging 
bracket, electrical wiring can be made

 

as follows:

Connect 

BLACK

 wire from fan to 

BLACK

 wire from 

ceiling with wire connector provided.
Connect 

WHITE

 wire from fan to 

WHITE

 wire from 

ceiling with wire connector provided.
Connect all 

GROUND 

(

GREEN

) wires together from 

fan to 

BARE

/

GREEN

 wire from ceiling with wire 

connector provided.

* Wrap each wire connector separately with electrical 
tape as an extra safety measure.

["Wiring"  continued on next page.]

black

black

white

white

black supply wire

ground
 (green
or bare)

white supply wire

from

ceiling

from fan

ground 
(green or bare)

*

Summary of Contents for SON52

Page 1: ...ssembly pg 6 Blade Assembly pg 7 Light Kit Assembly Optional pgs 7 8 Handheld Remote Control Assembly pgs 8 9 Automated Learning Process Activating Code pg 9 Remote Wall Control Operation pg 10 Testin...

Page 2: ...size wire connectors to use 5 Electrical diagrams are for reference only 6 After installation is complete check that all connections are absolutely secure 7 After making electrical connections spliced...

Page 3: ...iece p hardware packs page 2 d g k e j a b c 1 Unpacking Your Fan Carefully open the packaging Remove items from Styrofoam inserts Remove motor housing and place on carpet or Styrofoam to avoid damage...

Page 4: ...cal wiring around the back of the hanging bracket and away from the bracket opening Note It is very important that you use the proper hardware when installing the hanging bracket as this will support...

Page 5: ...canopy cover in hardware pack Slide yoke cover canopy cover and canopy over downrod Refer to diagram 3 Note Canopy cover must be turned with shiny side toward the motor housing Thread safety cable an...

Page 6: ...safety cable hanging bracket tab hanging ball slot wood ceiling joist wood screw and washer safety cable loop 6 Wiring WARNING Turn off circuit breakers to current fixture from breaker panel and be s...

Page 7: ...ing the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation betwe...

Page 8: ...hat plugs connect securely NOTE If you will NOT be using the light kit do NOT connect the plugs Light Kit Assembly continued on next page fitter plate motor plate female plug WARNING To reduce the ris...

Page 9: ...ASE CONTINUE WITH SECTION 10 for remote control assembly instructions If you have already installed the wall control but do not wish to use the handheld remote control please proceed to Section 11 Gen...

Page 10: ...over TOP I II IV VI III V 11 Automated Learning Process Activating Code wall control faceplate almond or white I II IV VI III V OFF ON SET button faceplate black handheld remote control I II IV VI III...

Page 11: ...e remote control operates all of the functions of the fan battery has been installed correctly If the wall and or remote controls do does not operate all of the fan functions refer to Troubleshooting...

Page 12: ...ing page 11 Problem Fan fails to operate Solutions 1 Check power to wall switch wall control 2 Verify that wall control optional use is wired properly 3 Check to be sure fan is wired properly 4 Learni...