page 6
5. Fan Assembly. (cont.)
hanging ball slot
hanging bracket tab
6. Wiring.
WARNING: Turn off circuit breakers to current
fixture from breaker panel and be sure switch is
turned to the OFF position.
CAUTION: Be sure outlet box is properly grounded
and that a ground wire (GREEN or Bare) is present.
Make sure all electrical connections comply with
Local Codes or Ordinances and the National
Electrical Code. If you are unfamiliar with electrical
wiring or if the house/building wires are different
colors than those referred to below, please use a
qualified electrician.
When downrod is secured in place on the hanging
bracket, electrical wiring can be made as follows:
Connect BLACK and BLUE wire from fan to BLACK
wire from ceiling with wire connector provided.
Connect WHITE wire from fan to WHITE wire from
ceiling with wire connector provided.
Connect all GROUND (GREEN) wires together
from fan to BARE/GREEN wire from ceiling with
wire connector provided.
If you intend to control the fan light with a
separate light switch, connect BLUE wire from fan
to the BLACK (or RED) supply from the
independent switch.
* Wrap each wire connector separately with
electrical tape as an extra safety measure.
This fan is remote control adaptable (remote control
sold separately).
With the hanging bracket secured to the outlet
box and able to support the fan, you are now
ready to hang your fan. Grab the fan firmly with
two hands. Slide downrod through opening in
hanging bracket and let hanging ball rest on the
hanging bracket. Turn the hanging ball slot until
it lines up with the hanging bracket tab.
WARNING: Failure to align slot in hanging ball
with tab in hanging bracket may result in serious
injury or death.
Tip: Seek the help of another person to hold the
stepladder in place and to lift the fan up to you
once you are set on the ladder.
white supply wire
*
black
black
white
white
blue
black supply wire
from ceiling
from fan
ground (green
or bare)
ground
(green or bare)
(wiring for fan)