background image

page 8

dimmer

switch

wall control

wire

wire

wire

12V battery

10. Handheld Remote Control Assembly.

IN ORDER TO USE THE HANDHELD REMOTE 
CONTROL, PLEASE CONTINUE WITH SECTION 10 for 
remote control assembly instructions. If you have 
already installed the wall control but do 

not

 wish 

to use the handheld remote control, please 
proceed to Section 11.

Gently pull on remote control cover to separate 
top and bottom parts. [

Refer to 

diagram 1

.

]

In order to use wall control as a handheld 
remote control, cut each wire on wall control 
(that was not previously used)--use wire cutters 
to cut off each wire as close to the wall control 
as possible. [

Refer to 

diagram 2

.

Install one 12-volt battery (included) in wall 
control. [

Refer to 

diagram 2

.

]

Since this fan does not have a light kit, the 
dimmer switch (labeled 

ON

 and 

D

) has been 

pre-set to the "OFF" position (

D

). If you wish to 

purchase a light kit and have dimming 
capability, please move the switch to the "ON" 
position (

ON

).

Align holes in wall control with posts located on 

inside

 of TOP part of remote control cover and 

press together firmly. Place wall control into 
BOTTOM part of remote control cover, aligning 
posts in top of remote control cover with post 
holes in the bottom. [

Refer to 

diagram 3

.

]

(

NOTE

: Make sure to align narrower ends of 

remote control cover before closing.) Squeeze 
top and bottom of remote control cover 
together until you hear a click at each end, 
indicating that the remote control cover has 
closed completely.

IMPORTANT

: Store the handheld remote 

control away from excess heat or humidity. To 
prevent damage to handheld remote control, 
remove the battery if remote control will not be 
used for long periods.

(top)

(bottom)

remote

control

cover

diagram 1

diagram 2

I

II

IV

VI

III

V

wall

control

remote control

cover, 

BOTTOM

post

hole

diagram 3

post
hole

remote control

cover, 

TOP

I

II

IV

VI

III

V

Summary of Contents for MND54

Page 1: ...sembly pg 7 Handheld Remote Control Assembly pg 8 Automated Learning Process Activating Code pg 9 Remote Wall Control Operation pg 10 Testing Your Fan pg 10 Troubleshooting pg 11 Parts Replacement pg...

Page 2: ...rned upward and pushed carefully up into the outlet box The wires should be spread apart with the grounded conductor and the equipment grounding conductor on opposite sides of the outlet box WARNING T...

Page 3: ...s Inventory IMPORTANT REMINDER You must use the parts provided with this fan for proper installation and safety a canopy 1 piece b hanging bracket 1 piece c downrod and hanging ball 1 piece d motor ho...

Page 4: ...gh point of ceiling Arrange electrical wiring around the back of the hanging bracket and away from the bracket opening Note It is very important that you use the proper hardware when installing the ha...

Page 5: ...gram 2 Thread downrod into the motor housing yoke until holes for pin and clip in downrod align with holes in yoke make sure wires do not get twisted Re insert pin and clip that were previously remove...

Page 6: ...with tab in hanging bracket may result in serious injury or death Tip Seek the help of another person to hold the stepladder in place and to help lift the fan up to you once you are set on the ladder...

Page 7: ...supply wire from ceiling from fan ground green or bare PLEASE NOTE Wall and or handheld remote control must be used for fan to operate If you do not wish to use the wall control please proceed to Sect...

Page 8: ...that was removed and secure all screws Align holes in switch housing cap with holes in switch housing plate Re insert screws that were previously removed and use a Phillips screwdriver to secure all s...

Page 9: ...the OFF position D If you wish to purchase a light kit and have dimming capability please move the switch to the ON position ON Align holes in wall control with posts located on inside of TOP part of...

Page 10: ...he power press and hold the fan SET button on the handheld remote control for 5 seconds or until light blinks twice Test the light and fan functions to confirm the learning process is complete see Sec...

Page 11: ...he remote control operates all of the functions of the fan battery has been installed correctly If the wall and or remote controls do does not operate all of the fan functions refer to Troubleshooting...

Page 12: ...purchaser for indoor use under the following provisions 1 YEAR WARRANTY CRAFTMADE will replace or repair any fan which has faulty performance due to a defect in material or workmanship Contact Craftm...

Page 13: ...ja de encendido P g 7 Ensamblaje del control remoto de mano P g 8 Proceso de aprendizaje autom tico Activar el c digo P g 9 Funcionamiento del control remoto de pared P g 10 Verificaci n del funcionam...

Page 14: ...s de haber terminado la instalaci n asegurarse de que todas las conexiones est n totalmente seguras 7 Despu s de haber terminado todas las conexiones el ctricas los conductores empalmados deben ser vo...

Page 15: ...ue utilizar las piezas provistas con este ventilador para una instalaci n adecuada y su seguridad a cubierta decorativa 1 unidad b soporte de montaje 1 unidad c tubo y bola que sirve para colgar 1 uni...

Page 16: ...s planas de su nueva o existente caja de salida Si hace la instalaci n en un techo abovedado colocar el soporte de montaje con la abertura dirigida hacia la parte alta del techo Arreglar el alambrado...

Page 17: ...ver a introducir el perno y la clavija que se quitaron anteriormente Apretar los tornillos de fijaci n del cuello y la tuerca completamente Referirse al diagrama 2 Localizar la tapa de la cubierta dec...

Page 18: ...gar con la parte saliente del soporte de montaje puede causar lesiones graves o la muerte Sugerencia solicitar ayuda de otra persona para mantener sujeta la escalera y para que le suba el ventilador c...

Page 19: ...un conector para cable provisto Como una medida de seguridad adicional envolver cada conector para cable por separado con cinta aisladora FAVOR DE DARSE CUENTA hay que utilizar el control de pared y...

Page 20: ...aspa con los agujeros en el brazo para el aspa localizado en el lado inferior del bastidor del motor referirse al dibujo al lado Asegurarse de fijarse en la etiqueta en el aspa que indique ESTE LADO...

Page 21: ...rior parte inferior cubierta del control remoto diagrama 1 interruptor del reductor de luz control de pared cable cable cable diagrama 2 bater a de 12V I II IV VI III V control de pared cubierta del c...

Page 22: ...terruptor de cualquier otro receptor o ventilador programable Conectar la electricidad y luego si se instal el control de pared poner el interruptor corredero en el control de pared en posici n ON enc...

Page 23: ...TA si el control de pared control remoto de mano interfiere con otros aparatos activar un c digo nuevo en el control de pared control remoto de mano cortando la corriente primero Repetir las instrucci...

Page 24: ...implicada en absoluto Esta limitaci n de da os emergentes no se aplicar en estados donde es prohibido Localizaci n de fallas ADVERTENCIA el no desconectar el suministro de fuerza el ctrica antes de ha...

Reviews: