background image

page 5

hanging ball slot

hanging bracket tab

motor housing

safety cable

wood screw

and washer

safety cable loop

wood

ceiling joist

canopy

5. Fan Assembly. (cont.)

6. Wiring.

WARNING

: Turn off circuit breakers to current fixture 

from breaker panel and be sure switch is turned to the 
OFF position.

CAUTION

Be sure outlet box is properly grounded and 

that a ground (

GREEN

 or Bare) wire is present.

Make sure all electrical connections comply with Local 
Codes or Ordinances and the National Electrical Code. If 
you are unfamiliar with electrical wiring or if the 
house/building wires are different colors than those 
referred to in the instructions, please use a qualified 
electrician.

Note

Excess lead wire length from the fan can be cut to 

the desired length and then stripped.

When downrod is secured in place on the hanging 
bracket, electrical wiring can be 
made

 

as follows:

Connect 

BLACK

 wire from fan to 

BLACK

 wire from 

ceiling with wire connector provided.
Connect 

WHITE

 wire from fan to 

WHITE

 wire from 

ceiling with wire connector provided.
Connect all 

GROUND 

(

GREEN

) wires together from fan 

to 

BARE

/

GREEN

 wire from ceiling with wire connector 

provided.

* Wrap each wire connector separately with electrical 
tape as an extra safety measure.

black

black

white

white

black supply wire

ground

 (green

or bare)

white supply wire

from ceiling

from fan

ground 
(green or bare)

*

[”

Wiring

” 

continued on following page

]

(wiring for fan)

With the hanging bracket secured to the outlet box and able 
to support the fan, you are now ready to hang your fan. Grab 
the fan firmly with two hands. Slide downrod through 
opening in hanging bracket and let hanging ball rest on the 
hanging bracket. Turn the hanging ball slot until it lines up 
with the hanging bracket tab.

WARNING

: Failure to align slot in hanging ball with tab in 

hanging bracket may result in serious injury or death.

Tip

: Seek the help of another person to hold the stepladder 

in place and to lift the fan up to you once you are set on the 
ladder.

Find a secure attachment point (wood ceiling joist highly 
recommended) and secure safety cable. It will be necessary 
to use a heavy duty wood screw, washer and lock washer 
(not supplied) with the safety cable loop. If necessary, adjust 
the loop at the end of the safety cable. The loop at the end of 
the safety cable should just fit over the threads on the wood 
screw. 

Test safety cable by pulling on loose end with pliers. If 

the safety cable slips, the loop must be adjusted tighter. 

Extra 

cable slack can be left in ceiling area. 

Summary of Contents for K10444

Page 1: ...y pg 2 Installation Preparation pg 3 Hanging Bracket Installation pg 3 Fan Assembly pgs 4 5 Wiring pgs 5 6 Canopy Assembly pg 6 Blade Assembly pg 7 Light Kit Assembly pgs 7 8 Handheld Remote Control A...

Page 2: ...conductor on opposite sides of the outlet box WARNING To reduce the risk of fire or electrical shock do not use this fan with any solid state speed control device or control fan speed with a full rang...

Page 3: ...iece h glass shade cage pre attached to light kit fitter 1 piece i yoke cover 1 piece j blade arm 5 pieces k rubber washer pre attached to light kit fitter 1 piece l hex nut pre attached to light kit...

Page 4: ...ical wiring around the back of the hanging bracket and away from the bracket opening Note It is very important that you use the proper hardware when installing the hanging bracket as this will support...

Page 5: ...ty cable and electrical wires through threaded end of downrod and pull extra wire slack from the upper end of the downrod Refer to diagram 2 Thread downrod into the motor housing yoke until holes for...

Page 6: ...ap each wire connector separately with electrical tape as an extra safety measure black black white white black supply wire ground green or bare white supply wire from ceiling from fan ground green or...

Page 7: ...canopy Align holes in anti sway adapter with holes on underside of canopy and then re insert the screws that were previously removed Tighten both screws securely Slide canopy up to anit sway adapter...

Page 8: ...using aligning holes in blade arm with holes located on the underside of the motor housing refer to drawing at right Attach blade arm with blade arm screws lock washers Before securing screws permanen...

Page 9: ...e insert screw that was previously removed and securely tighten all 3 screws with Phillips screwdriver Install 3 candelabra base 4 watt LED bulbs included Important When replacing bulbs please allow g...

Page 10: ...ll control as possible Refer to diagram 2 Install one battery included in wall control Refer to diagram 2 The dimmer switch labeled DIM and ON has been pre set to the ON position DIM If you do not wis...

Page 11: ...fan Restore electrical power and then if using wall control set slider switch on wall control to the ON position Within 60 seconds of turning on the wall control press and hold the fan SET button on t...

Page 12: ...ote control operates all of the functions of the fan battery has been installed correctly If the wall and or remote controls do does not operate all of the fan functions refer to Troubleshooting secti...

Page 13: ...k to be sure set screw s on motor housing yoke is are tightened securely 3 Check to be sure set screw on hanging ball is tightened securely Warranty WARNING Failure to disconnect power supply prior to...